5.11 ELECTRIC CONNECTION
Warning: the appliance must be installed by an authorized technician!
• The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension
specific of every model, as described in the technical datas table (see
FEATURES a pag. 31
).
• The plug must be easily accessible when the appliance is installed.
• Please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not
efficient, please endow you with one in compliance with the law.
• Connect the supply cable first on the back of the stove (see
Fig. 60
Fig. 61
) and then at a wall electric socket.
Fig. 60 - Electric socket with master switch
Fig. 61 - Plug connected
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
5.12 CONNECTION TO THE EXTERNAL THERMOSTAT (ATRIUM - ROXY - MADISON - TABLA - SOLO 5)
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the menu key for a few seconds (1).
• Repeatedly press the P2 key until
M8 - Technical settings
"
M8-SEt tEcHnic
" appears.
• Select by pressing the P3 key.
• Set the password with keys P1 or P2 (keeping the key pressed accelerates the setting).
• Confirm by pressing the P3 key.
• Press the P1 or P2 keys until
M8 - 2 General settings
"
M8-2 SEt GEnErAL
" appears.
• Confirm with P3.
• Scroll with the P3 key up to:
Pr46 Enable Remote
"
Pr46 rEMoto EnAbLEd
".
• Press the P1 or P2 key to modify the status.
• Confirm with the P3 key.
• Scroll to
MB Output
"
Mb EScAPE
" with key P1 or P2.
• Confirm with P3 key.
•
• Press P1 (temperature setting) and set
t-e
“
t-e
” value. The external thermostat is now enabled.
5.13 CONNECTION TO THE EXTERNAL THERMOSTAT (SPIRIT
3
- GRACE
3
)
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the "
menu
" button.
• Scroll with the arrows to "
Settings
".
• Select by pressing "
menu
".
• Scroll with the arrows again to "
Ext.Thermostat
".
• Select by pressing "
menu
".