5

     

TURNING ON THE CHIME FEATURE

If checked, your security system will operate in the "CHIME" mode, allowing the monitoring
of pre-designated zones while the security system is not armed. While in the "CHIME" mode,
the opening of any of these zones will produce a 1 second beep from the keypad control. To
activate this feature, press [ 1 ] for "CHIME" mode. Five seconds after pressing the "CHIME"
digit,  a  one second tone will occur indicating that this feature has been activated. Repeat this
procedure to turn the "CHIME" feature off.

     

KEYPAD ACTIVATED PANIC/HOLD-UP ALARM

If checked, this feature has been selected by your installing company. If so, when the star [

r

]

and pound [#] keys are pressed at the same time for one second, a local audible alarm will
sound. If your system is connected to a monitoring center, an emergency report could be
transmitted to that center. These keys should only be pressed in an emergency situation
requiring immediate response by law enforcement personnel. 

PLEASE NOTE: Some Panic/Hold-Up alarms are programmed to be silent at the protected
site while reporting an alarm to the monitoring center. Check with your installing company to
determine how your security system will respond to the Panic/Hold-Up activation.

     

KEYPAD ACTIVATED FIRE ALARM

If checked, this feature has been selected by your installing company. If so, you can activate
the Fire alarm by pressing the one [1] and three [3] keys at the same time for one second. If
your system is connected to a monitoring center, an emergency report could be sent to that
center. These keys should only be pressed in an emergency situation requiring response by
fire department personnel.

     

KEYPAD ACTIVATED AUXILIARY ALARM

If checked, this feature has been selected by your installing company. If so, you can activate
the auxiliary alarm by pressing the four [4] and six [6] keys at the same time for one second.
If your system is connected to a monitoring center, an emergency report could be sent to that
center. These keys should only be pressed in an emergency situation requiring response by
emergency personnel.

     

FIRE ZONE

If checked, your system has zones designated as "FIRE" zones. When this option is selected,
and approved heat or smoke detectors are attached to these selected zones, a Fire alarm
sound can be initiated from the security system. You should familiarize yourself and your
family or staff with this sound (see page 1, Fire Alarm sound) and follow an evacuation plan
if this "FIRE" alarm sound is heard. (see page 8 for assistance in formulating an evacuation
plan). To silence the audible "FIRE" alarm sound, enter a valid code. To reset the zone LEDs
designated as "FIRE" zones and /or smoke detectors, press the [#] key (reset) on the keypad.
After 10 seconds, the zone LEDs designated as "FIRE" zones should extinguish, and the light
on the affected smoke detector should go out.  If you are unable to reset the LEDs for
designated "FIRE" zones or smoke detectors after all smoke has cleared, you should
immediately call the service phone number listed on page 1 of this booklet. 

Содержание RANGER 7600

Страница 1: ...hime 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Secondary Exit Delay Time Entry Delay Time Secondary Entry Delay Time Fire Alarm Sound check one 9 Steady Siren 9 Pulsing Bell Burglar Alarm Sound check one 9 Yelp Siren 9 Steady Bell ZONE DESCRIPTIONS CHECK FIRE ZONES U ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ...

Страница 2: ...TAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is ...

Страница 3: ...time noted on page 1 If you choose to stay within the protected area insure that all interior zones which may be tripped by your movement are bypassed HOW TO DISARM YOUR SECURITY SYSTEM When you enter the protected area through one of the designated entry exit doors the keypad control will sound a continuous tone beep for the duration of the entry delay time or until you enter a valid code After a...

Страница 4: ...ing company may have programmed the INSTANT option to occur in conjunction with the AUTOMATIC BYPASS feature In this case the INSTANT light and the bypassed ZONE lights will become illuminated at the end of the exit delay If this occurs you still have the ability to turn the INSTANT feature off and or on by pressing the r key GROUP BYPASS OPTION If checked the GROUP BYPASS option has been selected...

Страница 5: ...ame time for one second If your system is connected to a monitoring center an emergency report could be sent to that center These keys should only be pressed in an emergency situation requiring response by fire department personnel KEYPAD ACTIVATED AUXILIARY ALARM If checked this feature has been selected by your installing company If so you can activate the auxiliary alarm by pressing the four 4 ...

Страница 6: ...de is 1 2 3 4 and you want to change it to 5 3 4 2 the programming sequence would be as follows Press r 1 this enters programming for user 1 Then enter the current Master Code of 1 2 3 4 Press r 1 to verify user 1 programming Now enter your new Master Code of 5 3 4 2 and exit programming with r 1 The entire sequence would consist of pressing 17 keys as follows r 1 1 2 3 4 r 1 5 3 4 2 r 1 PROGRAMMI...

Страница 7: ...OL TONES BEEPS A sounder is built into the keypad and may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a dayzone is violated while the system is disarmed Pulses when a FIRE zone has a trouble condition Pulses when the armed status changes and the AC power is off Beeps 3 times for trying to arm with the READY light ...

Страница 8: ...dures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone NOTE After the installat...

Страница 9: ...9 SYSTEM NOTES ...

Страница 10: ...7600 USER S MANUAL 7600UE98 REV E 02 10 98 ...