background image

 

P/N 466-5559-

EN • REV E • ISS 15OCT21 

 

9 / 12 

System Ready 

The system is ready to arm. 

Programming 

For full system programming, refer to 

xGenConnect Installation 

and Programming Guide

Specifications 

Compatibility 

xGenConnect panel series 

Code combinations 

10 000 to 100 000 000 (4 to 8 digits) 

There are no invalid code combinations. 

Voltage 

9 to 15 VDC (provided by panel) 

Current consumption (at 13.7 V DC) 

Nominal 

NXG-1830-EUR, NXG-1831-EUR: 90 mA 
NXG-1832-EUR, NXG-1833-EUR: 130 mA 

Minimal (all lights off) 

NXG-1830-EUR, NXG-1831-EUR: 35 mA 
NXG-1832-EUR, NXG-1833-EUR: 40 mA 

Maximum 

NXG-1830-EUR, NXG-1831-EUR: 160 mA 
NXG-1832-EUR, NXG-1833-EUR: 200 mA 

Input 

Resistive, wiring compliant with 
xGenConnect panel inputs 

Output 

NXG-1832-EUR, NXG-1833-EUR only 

Open collector type 
Internal 10 kΩ pullup to Main PWR line  

Max. load for OC sink 

100 mA 

Max. voltage connected 
externally 

16 VDC 

Overcurrent protection 

Built in 

Mifare reader 

NXG-1832-EUR, NXG-1833-EUR only 

Carrier frequency 

13.560 MHz 

Bandwidth 

1.696 MHz      

Maximum power output 

42 dBμA/m 

Supported cards 

NXG-180x-5 (compatible with Mifare 
DESFire EV2, EV3) 

Wiring 

xGen 4-wire bus 

Mounting height 

≤2 m 

Dimensions (W × H × D)  133 x 130 x 25 mm 

Colour 

NXG-1830-EUR, NXG-1832-EUR: White 
NXG-1831-EUR, NXG-1833-EUR: 
Anthracite 

Weight 

0.3 kg 

Operating temperature  

−10 to +50°C 

Maximum relative 
humidity 

95% noncondensing 

Serviceable parts 

There are no serviceable parts 

Regulatory information 

Manufacturer 

Placed on the market by: 
Carrier Fire & Security Americas Corporation Inc. 
13995 Pasteur Blvd 
Palm Beach Gardens, FL 33418, USA 

Authorized EU manufacturing representative: 
Carrier Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR 
SALE TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. CARRIER FIRE & 
SECURITY CANNOT PROVIDE ANY 
ASSURANCE THAT ANY PERSON OR ENTITY 
BUYING ITS PRODUCTS, INCLUDING ANY 
“AUTHORIZED DEALER” OR “AUTHORIZED 
RESELLER”, IS PROPERLY TRAINED OR 
EXPERIENCED TO CORRECTLY INSTALL 
FIRE AND SECURITY RELATED PRODUCTS. 

For more information on warranty disclaimers and 
product safety information, please check 
https://firesecurityproducts.com/policy/product-
warning/ 
or scan the QR code. 

Certification 

  

 

EN 50131-3 
Security Grade 2, Environmental class II 

Tested and certified by Telefication B.V.

 

European Union 
directives 

NXG-1830-EUR, NXG-1831-EUR: Carrier Fire & 
Security hereby declares that this device is in 
compliance with the applicable requirements and 
provisions of the Directive 2014/30/EU and/or 
2014/35/EU. For more information see 
firesecurityproducts.com 

 

NXG-1832-EUR, NXG-1833-EUR: Carrier Fire & 
Security hereby declares that this device is in 
compliance with the applicable requirements and 
provisions of all applicable rules and regulations, 
including but not limited to the Directive 
2014/53/EU. For more information see: 
firesecurityproducts.com 

REACH 

Product may contain substances that are also 
Candidate List substances in a concentration 
above 0.1% w/w, per the most recently published 
Candidate List found at ECHA Web site. 

Safe use information can be found at 
https://firesecurityproducts.com/en/content/intrusi
on-intro 

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European Union. 
For proper recycling, return this product to your 
local supplier upon the purchase of equivalent 
new equipment, or dispose of it at designated 
collection points. For more information see: 
recyclethis.info. 

Product 
documentation 

 

Please consult the following weblink to retrieve 
the electronic version of the product 
documentation. 

This link will guide you to the EMEA regional 
contact page. On this page you can request your 
login to the secured web portal where all manuals 
are stored. 

https://firesecurityproducts.com/en/contact 

Contact information 

www.firesecurityproducts.com/en/page/caddx 

 

 

 

Содержание NXG-183x-EUR Series

Страница 1: ...UR and NXG 1833 EUR keypads are equipped with a Mifare card reader that allows you to use cards to log into the system and perform particular operations NXG 180x 5 series of cards The cards fobs must...

Страница 2: ...Arm Mode then Stay Using Up 2 and Down 8 buttons select one of the following Stay Arming modes Stay Stay Instant Stay Instant Night Next press Enter enter your PIN and then press Enter again Note In...

Страница 3: ...ror and Fail to Close event are logged in the xGen event history Check that the zone is secure and try to arm the partition s again Disarm Partitions Enter a valid PIN code to unlock the screen Typica...

Страница 4: ...to insert special characters Press multiple times to select a special character and add it to the text Navigating the Main Menu To enter the user or programming menu depending on the user privileges p...

Страница 5: ...lar State UltraSync Status UltraSyncPath Cellular Service Signal Strength of the cellular communication Operator ID Radio Technology Active SIM Wi Fi Status Wi Fi SSID Device Unique ID UID Panel Detai...

Страница 6: ...y system is critical to ensure it operates correctly and alarm messages are being sent in case of an alarm detection 1 Enter a valid PIN to unlock the screensaver 2 Press Enter 3 Go to Testing 4 Selec...

Страница 7: ...s Once the user number is shown on the screen present the card to the reader This runs the following operations assign the card to user enable the card and secure the card Note Present the card to the...

Страница 8: ...me of the faulty zone or a name of the device in case of system faults Door Faults The following door faults may appear on the screen Door Left Open DLO Door is still opened when the Door Zone Shunt T...

Страница 9: ...HAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS INCLUDING ANY AUTHORIZED DEALER OR AUTHORIZED RESELLER IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS For more...

Страница 10: ...10 12 P N 466 5559 EN REV E ISS 15OCT21...

Страница 11: ...P N 466 5559 EN REV E ISS 15OCT21 11 12...

Страница 12: ...12 12 P N 466 5559 EN REV E ISS 15OCT21...

Отзывы: