2
2
3. Assembly Instructions
PLEASE NOTE:
Please ensure all protective packaging and plastic are removed from the appliance before use.
This appliance may only be used with an approved hose and regulator (hose and regulator supplied with this unit in South Africa)
Connect the regulator to a CADAC 3kg, 5kg or 7kg LPG cylinder prior to use.
If you wish to use the appliance with a 9kg cylinder, please ensure that you have purchased the correct hose and regulator suitable for a
9kg cylinder.
The hose length should be no less than 600 mm and shall not exceed 1.2 m and replace when the hose is damaged or shows signs of brittleness
or cracks.
Do not twist or pinch the hose. Ensure that it is routed away from the Stove Body so as to prevent deterioration / damage to the hose
caused by heat.
Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to the stop.
Open the gas valve on the cylinder and test for any leaks.
Check all gas connections for any signs of gas leaks.
Your appliance is now ready to be used.
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37),
Appliance categories: (DK, FI, NO, NL, SE, AT, DE, BE, ES, FR, IE, IT, PT, GB, CH)
Push an approved hose onto the valve tailpiece until it is properly seated. On the other end, attach a suitable low pressure regulator.
I3B/P(30) : 30mbar Butane confi gurations regulator or 30mbar Propane confi gurations regulator.
I3B/P(37) : 37mbar Butane confi gurations regulator or 37mbar Propane confi gurations regulator.
I3+(28-30/37) : 30mbar Butane confi gurations regulator or 37mbar Propane confi gurations regulator.
Again making sure that the hose is properly seated. The type of hose used shall comply with the relevant EN standard and locate
requirement. In South Africa the regulator used must comply with SANS 1237.
I 3B/P (50) Appliance category: (AT, DE)
I3B/P(50) : 50mbar Butane confi gurations regulator or 50mbar Propane confi gurations regulator or 50mbar butane/propane mixture
confi gurations regulator.
Screw a hose with the correct threaded fi ttings on each end, onto the left hand 1/4” BSP thread of the valve. Attache a suitable 50mbar
low-pressure regulator on the end of the hose. The hose assembly used must comply with DIN 4815 part 2 or equivalent.
Country of Use
BE, CH, CY, CZ, ES, FR, GB, GR,
IE, IT, LT, LU, LV, PT, SK & SI
PL
BE, CY, DK, EE,
FR, FI, HU, IT, LT,
NL, NO, SE, SI,
SK, RO, HR, TR,
BG, IS,LU, MT
,
& ZA
AT, CH, DE & SK
Appliance Catagories
I
3+(28-30/37)
I
3B/P (37)
I
3B/P (30)
I
3B/P (50)
Allowable gasses
Butane-G30
Propane-G31
Butane-G30, Propane-G31 or their mixture
Gas Pressure
28-30mBar
37mBar
37mBar
28-30mBar
(2.8kPa for South
Africa)
50mBar
Jet Number
0.71
0.71
0.71
0.62
Nominal Usage
Butane - 145.5 g/h
per burner
(145.5g/h x 2 = 291g/h in total)
Butane - 160 g/h
per burner
(160g/h x 2 = 320g/h
in total)
Butane - 145.5g/h
per burner
(145.5g/h x 2 =
291g/h in total)
Butane - 145.5g/h
per burner
(145.5g/h x 2 =
291g/h in total)
Gross nom. heat input
2kW per burner
(2kW x 2 = 4kW in total)
2.2kW per burner
(2.2kW x 2 = 4.4kW
in total)
2kW per burner
(2kW x 2 = 4kW
in total)
2kW per burner
(2kW x 2 = 4kW
in total)
Country Name and Abbreviations
AE = United Arab Emirates
AL = Albania
AT = Austria
BE = Belgium
CH = Switzerland
CZ = Czech Republic
DE = Germany
DK = Denmark
ES = Spain
FI = Finland
FR = France
GB = United Kingdom
GR = Greece
HR = Croatia
IT = Italy
JP = Japan
KR = Korea
NL = Netherlands
NO = Norway
PL = Poland
PT = Portugal
RO = Romania
RU = Russia
RS = Serbia
SI = Slovenia
SK = Slovakia
SE = Sweden
TR = Turkey
ZA = South Africa
GB