SAFETY NOTICES

CAUTION

Indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

!

!

  

 WARNING

Indicates a hazardous situation which, if not 

avoided, could result in death or serious injury.

!

  

DANGER

Indicates a hazardous situation which, if not 

avoided, WILL result in death or serious injury.

!

  

This is the safety alert symbol.  Symbol alerts you 

to potential personal injury hazards. Obey all safety 

messages following this symbol to avoid possible 

injury or death.

Become familiar with symbols identifying potential hazards.

Boiler installation shall be completed by qualified agency.  

 WARNING

Do not tamper with or use this boiler for any 

purpose other than its intended use. Failure to follow 

these instructions could result in death or serious 

injury. Use only manufacturer recommended parts 

and accessories.

!

  

CAUTION

Laceration, burn hazard.  Metal edges and parts 

may have sharp edges and/or may be hot. Use 

appropriate personal protection equipment to 

include safety glasses and gloves when installing 

or servicing this boiler. Failure to follow these 

instructions could result in minor or moderate injury. 

!

!

  

NOTICE

Used to address practices not related to personal 

injury.

 WARNING

Fire, explosion, asphyxiation and electrical shock 

hazard.  Improper installation could result in death 

or serious injury.  Read this manual and understand 

all requirements before beginning installation.

!

  

FOR YOUR SAFETY READ BEFORE OPERATING

Hot Water Can Scald

!

Water heated to temperature for clothes washing, 

dish washing and other sanitizing needs can scald and 

cause permanent injury.

Children, elderly, and infirm or physically handicapped 

persons are more likely to be permanently injured by 

hot water. Never leave them unattended in bathtub or 

shower. Never allow small children to use a hot water 

tap or draw their own bath.

If anyone using hot water in the building fits the above 

description, or if state laws or local codes require 

certain water temperatures at hot water taps, you 

must take special precautions:

• 

Use lowest possible temperature setting.

• Install some type of tempering device, such as 

an automatic mixing valve, at hot water tap or 

water heater. Automatic mixing valve must be 

selected and installed according to manufacturer's 

recommendations and instructions.

• Water passing out of drain valves may be 

extremely hot. To avoid injury:

•  Make sure all connections are tight.

• 

 Direct water flow away from any person.

   

DANGER

!

  

Water 

Temperature 

Setting

1st Degree Burn 

Exposure Time For 

An Adult

2nd and 3rd Degree Burn 

Exposure Time For An 

Adult

120°  F

1 minute

5 minutes

130°  F

5 seconds

30 seconds

140° F

2 seconds

5 seconds

150°  F

1 second

1.5 seconds

160°  F

Instantaneous

0.5 seconds

Note:

 Warning for Infants, Children, and Elderly: 

Great care must be taken when exposing the  

aforementioned groups to warm or hot water as they 

can be badly burned in exposure times less than half 

of the time for an adult.

WARNING

Fire, Explosion, Asphyxiation, Electrical shock 

hazard! Flooding will result in damages such as 

electrical problems, corrosion, inoperative parts, 

mold and other unforeseen issues which can 

occur over time. Any equipment determined by 

a professional as damaged by a flood, defined as 

excess of water or other liquid, shall be replaced. 

Failure to follow these directions will result in a 

Hazardous Situation.

!

  

Содержание BW4BAH000112

Страница 1: ...AH000112 BW5BAH000112 BW5RAH000112 BW4BAH000175 BW4RAH000175 BW5BAH000175 BW5RAH000175 Models Series D BW4BAH000217 BW4RAH000217 BW5BAH000217 BW5RAH000217 CAC BDP 7310 WEST MORRIS ST INDIANAPOLIS IN 4...

Страница 2: ...nts portion of remaining heat that can be applied to heat radiation or terminal units finned tube baseboard cast iron radiators radiant floor etc Difference between Heating Capacity and Net AHRI Ratin...

Страница 3: ...B R AH000217ADAA 1 55 217 189 164 86 0 5 13 7 21 6 11 Mbh 1 000 BTU per hour BTU British Thermal Unit Heating Capacity based on 13 1 CO2 with a 0 02 w c draft over fire and a 1 smoke or less Testing w...

Страница 4: ...ing needs can scald and cause permanent injury Children elderly and infirm or physically handicapped persons are more likely to be permanently injured by hot water Never leave them unattended in batht...

Страница 5: ...mance and life expectancy can be hindered by overfilling the boiler Recommend initial fill pressure of 10 12 psig For higher fill pressures expansion tank s air charge will need to be increased to mat...

Страница 6: ...replacement of any parts that may normally require attention Install boilers at least 6 from combustible material on left side rear and above and at least 24 on right side and front Allow at least 24...

Страница 7: ...ION FROM RADIATION CIRCULATING PUMP IN RETURN LINE OR AFTER THE EXPANSION TANK SHUT OFF VALVE OIL FILTER OIL LINES FOUNDATIONS TO OUTSIDE LINES TO OTHER APPLIANCES SERVICE LINE OVERCURRENT PROTECTED S...

Страница 8: ...gs communicating directly with additional room s of sufficient volume so the combined volume of all spaces meets the criteria for unconfined space Total input of all combustion equipment installed in...

Страница 9: ...all equipment in the enclosure 3 When communicating with outdoors through horizontal ducts each opening shall have minimum free area of one square inch per 2 000 Btu per hour of total input rating of...

Страница 10: ...elbow provided with boiler See Figures 6a and 6b A Install safety relief valve with spindle in vertical position B Do not install shutoff valve between boiler and safety relief valve C Install dischar...

Страница 11: ...o prevent this condensation in boiler and venting is 120 F Boiler used in heating system where design water temperatures below 140 F are desired e g radiant floor heating a 3 way or 4 way mixing valve...

Страница 12: ...RRANGED FOR POWER PURGING AIR OUT OF THE SYSTEM PIPING REFER TO THIS MANUAL S SECTION ON FILLING THE SYSTEM WITH WATER OPTION 1 Figure 7 Bypass Piping Arrangement Diagram SYSTEM PIPING Adjust two thro...

Страница 13: ...IPING PUMPS AWAY FROM EXPANSION TANK NOTE CIRCULATORCANALSOBEINSTALLED ON RETURN PIPING PIPING ARRANGED FOR POWER PURGING AIR OUT OF SYSTEM PIPING REFER TO THIS MANUAL S SECTION ON FILLING THE SYSTEM...

Страница 14: ...ON SUPPLY PIPING PUMPS AWAY FROM EXPANSION TANK PIPING ARRANGED FOR POWER PURGING AIR OUT OF SYSTEM PIPING REFER TO THIS MANUAL S SECTION ON FILLING THE SYSTEM WITH WATER OPTION 1 SYSTEM PIPING Figure...

Страница 15: ...E BOILER CIRCULATOR ON SUPPLY PIPING PUMPS AWAY FROM EXPANSION TANK PER THIS MANUAL USE OPTION 2 IN FILLING THE SYSTEM WITH WATER THIS PIPING ARRANGEMENT CAN BE USED WITH ZONE VALVES OR ZONE CIRCULATO...

Страница 16: ...t draws not continuous flow NOTICE Do not use tankless coil if your water is excessively hard with lime or other deposits which will accumulate inside the coil When using tankless coil boiler is confi...

Страница 17: ...increase fuel consumption Tankless coil performance will fall as concentration of antifreeze is increased Refer to boiler and piping water volumes tables BOILER WATER VOLUMES Number of Boiler Section...

Страница 18: ...d boilers for connections to vents or chimneys vent installations shall be in accordance with applicable provisions of NFPA 31 Standard for the Installation of Oil Burning Equipment latest edition and...

Страница 19: ...T 1 4 INCH PER FOOT OF HORIZONTAL RUN MUST BE AT LEAST 4 INCHES THICK AND BE TIGHT TIGHT CLEAN OUT DOOR SEALED IN THIMBLE TIGHT SMOOTH CORRECTLY SIZED Minimum Height Must be 3 FT higher than highest p...

Страница 20: ...comply with the latest revision of the National Electrical Code any other national state or local codes or regulations Connect 120 volt electrical supply to L1 and L2 terminals on limit and two therm...

Страница 21: ...Control with Riello F5 Burner ELECTRICAL WIRING When low limit is used set ELL Parameter on L7248 Honeywell control to ON Boilers factory equipped with tankless coil are factory set to ON When low lim...

Страница 22: ...lve When power purging drain valve runs air free close isolation valve or zone valve Repeat this procedure for remaining heating zones C Once all zones are filled with water and purged of air close po...

Страница 23: ...a lack of combustion air burner flame will be dark orange and formation of soot will occur in heating unit In buildings of conventional frame brick or stone construction that do not have utility rooms...

Страница 24: ...5 BAH000217 AFG50MDASN 1 55 2 1 2 1 25 60 B 155 NO V1 2 10 2 2 3 4 RIELLO 40F5 BOILER MODEL BURNER MODEL INPUT RATE gph INSERTION DEPTH DELAVAN OIL NOZZLE PUMP PRESSURE psi TURBULATOR SETTING AIR SHU...

Страница 25: ...ero and four are scale indicators only From left to right first line is 4 and last line 0 On some models scale indicators are 0 and 3 Figure 15 Burner Adjustments and Settings Figure 16 Riello Electro...

Страница 26: ...floor on inside wall Locate thermostat to sense average room temperature avoid the following THERMOSTAT LOCATIONS TO AVOID DEAD SPOTS HOT SPOTS COLD SPOTS Behind doors Concealed pipes Concealed pipes...

Страница 27: ...boiler and tank Water will rise to normal height in tank if system has automatic fill valve otherwise manually refill system Diaphragm Expansion Tank Tank may become water logged Frequent automatic op...

Страница 28: ...ly vacuum soot accumulations from combustion chamber area take care to not damage any of refractory or blanket insulation To gain access to combustion chamber first check that shut off valve on fuel o...

Страница 29: ...5 Install burner drawer assembly make sure head location and size if applicable are per manufacturer s recommendations If burner being used has damaged head replace head with same head recommended fo...

Страница 30: ...o instructions Radiators not heating Open radiator vents to excess air Check flow control valve if used It may be in closed position Circulating pump not running Check over current protection Check re...

Страница 31: ...31 IM BW4 5 02 240013014 Rev B 12 15 2020 Taco 007 Pump Curve PUMP CURVE 007...

Страница 32: ...l energy management system that serves the same function THIS OVERRIDE MUST NOT BE USED UNLESS AT LEAST ONE OF THE FOLLOWING CONDITIONS IS TRUE An external energy management system is installed that r...