CAC / BDP 38GRQ Скачать руководство пользователя страница 8

8

CLEANING, MAINTENANCE AND TROUBLESHOOTING

ELECTRICAL SHOCK HAZARD

Failure to follow this caution may result in personal injury

or death.

Always turn off power to the system before performing any

cleaning or maintenance to the system. Turn off the outdoor

disconnect switch located near outdoor unit. Be sure to

disconnect indoor unit if on a separate switch

CAUTION

!

EQUIPMENT DAMAGE/OPERATION HAZARD

Failure to follow this caution may result in equipment

damage or improper unit operation.

Operating the system with dirty air filters may damage the

indoor unit and could cause reduced cooling performance,

intermittent system operation, frost build- up on indoor coil

or blown fuses.

CAUTION

!

Periodic Maintenance

Periodic maintenance is recommended to ensure proper operation

of the unit. Recommended maintenance intervals may vary

depending on the installation environment, e.g., dusty zones, etc.

Refer to Table 1.

CUT HAZARD

Failure to follow this caution may result in personal injury.
The coil fins are very sharp. Use caution when cleaning.
Always wear safety protection.

CAUTION

!

Cleaning the Coil

Clean the coil at the beginning of each cooling season, or when

necessary. Use a vacuum cleaner or a long- bristle brush to avoid

damage to the coil fins.

Air Filters

Remove and clean the air filters once a month.

NOTE:

If air filters show signs of excessive wear or are torn, they

must be replaced. Contact your local dealer for replacement filters.

1. Open front panel on unit.
2. Pull filters down to remove.
3. Vacuum filters.
4. Clean with warm water.
5. Shake filter to remove excess water and dry thoroughly.
6. Replace filter by sliding into rack until filter snaps in place.
7. Close front panel on unit.

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment

damage.

When cleaning the front panel, do not use water hotter than

105

_

F (40.56

_

C) and do not pour water onto the fan coil.

Do not use abrasive or petroleum based cleaners as they

may damage the front panel.

CAUTION

!

Indoor Unit Front Panel

To clean the front panel on the indoor unit, wipe the outside with

a soft, dry cloth. If necessary, a mild liquid detergent can be applied

and wiped off with a dry cloth.

Preparing for Extended Shutdown Period

Clean the filters and reposition them in the unit. Operate the unit

in Fan only mode for 12 hours to dry all internal parts.
Turn main power supply off and remove batteries from the remote

control.

System Operation Recommendations

The items outlined in the following list helps to assure proper

system operation:

S

Replace both remote control batteries at the same time.

S

Point the remote control toward the unit display panel when
transmitting a command.

S

Keep doors and windows closed while unit is operating.

S

Contact an authorized service representative if a problem arises
that cannot be easily resolved.

S

Do not perform cleaning or maintenance activities while unit
is on.

S

Keep display panel on unit away from direct sunlight and heat
as this may interfere with remote control transmissions.

S

Do not block air intakes and outlets on the indoor or outdoor

units.

Energy Saving Recommendations

The following recommendations add greater efficiency to the

ductfree system:

S

Select a comfortable thermostat setting and leave it at chosen
setting. Avoid continually raising and lowering the setting.

S

Keep unit filter clean. Frequent cleaning may be necessary
depending on indoor air quality.

S

Use drapes, curtains or shades to keep direct sunlight from

heating room on very hot days.

S

Do not obstruct air intake on front panel.

S

Turn on air conditioning before indoor air becomes too
uncomfortable.

Troubleshooting

Refer to Table 2 before contacting your local dealer.

Содержание 38GRQ

Страница 1: ...nd serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ___________________________________ Serial ___________________________________ INSTALLATION INFORMATION Date Installed _____________________________ DEALERSHIP CONTACT...

Страница 2: ...ries when modifying this product WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only using approved tubing and...

Страница 3: ...inHose 7 Refrigerant Lines Outdoor unit 4 Air outlet Air inlet Air inlet Air outlet 3 1 2 5 6 7 Fig 1 Indoor Outdoor Unit DISPLAY PANELS NOTE The display panel on the indoor unit can be turned on or off using the LIGHT button on the remote control The temperature readout will be replaced by an error code if there is a malfunction ...

Страница 4: ...ton 4 Heat button 6 I Feel button 7 Up down swing button 9 Left right swing button 14 Temp button 15 Sleep button Light button 16 17 Wifi button 11 Clock button 12 13 X Fan button 10 T ON T OFF button 8 Mode button 5 Fan button Blank Fig 2 Remote Control Remote Control Display Fig 3 Remote Control Display ...

Страница 5: ...o 6 feet from the indoor high wall unit 3 Point the remote controller at the indoor wall unit and press the Blank button for 3 seconds 4 The indoor high wall unit provides 3 beeps to signal a successful match 5 Press the Power ON button on the remote controller The green indicator light displays on the indoor high wall unit 6 The remote controller is matched and ready for use If the indoor unit an...

Страница 6: ...arge directions including Continuous Sweep The Horizontal Swing Louver icon appears Press this button to set swing angle which changes in direction as shown in the following figure no display stops at current position Fig 9 Horizontal Swing Louver Angles I FEEL Press this button to use the I FEEL function and the icon appears The unit senses room temperature at the remote controller instead of at ...

Страница 7: ...ons to cancel the Sleep 3 Mode NOTE During this procedure if no button is pressed within 10 seconds the remote controller automatically exits the sleep curve setting and resumes the original display If the ON OFF MODE TIMER SLEEP COOLING or HEATING button is pressed during the setting or inquiry procedure the remote controller exits the sleep curve setting SIESTA MODE 4 In Siesta Mode the unit aut...

Страница 8: ...tion may result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If necessary a mild liquid detergent can be applied a...

Страница 9: ...sert plug Restart unit Water leaks into room from Indoor unit Condensing water has overflowed Check indoor condensing drain or call your representative Unit System Does Not Work To protect the unit upon an immediate restart after a stop the system controller delays the unit for 3 minutes before allowing the unit to start back up The circuit breaker has tripped or a fuse has blown Power failure Err...

Страница 10: ...S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No OM38 40GR 03 Replaces OM38 40GR 02 Edition Date 06 15 ...

Отзывы: