Chapter 2: Local Management
2-14
WPIM-DI Local Management Guide
9. Use the arrow keys to highlight DI Enabled. Press the SPACE bar to
select On (Drop and Insert function enabled), or Off (Drop and Insert
function disabled), or diDataEnable (Drop and Insert is enabled and
the data that comes to the host goes to the DI port), then press ENTER.
10. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message “Save Done!” appears and Local Management
saves the changes to memory.
11. Access the WAN Interface Configuration screen by using the arrow
keys to highlight the WAN INT CONFIG option, then press ENTER.
2.3.2
WPIM-DI Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Refer to Figure 2-6 and proceed with the following steps to configure the
WAN Interface through Local Management.
1. Set the WAN connection Interface Number by typing the same
number into the Interface Number field that was input into the
Timeslots in the WAN Physical Configuration screen, then press
ENTER.
2. Unless the user sets the Max Xmit Unit, the WPIM-DI automatically
sets the Max Xmit Unit to the default after the active protocol (PPP or
FR) is selected.
3. Use the arrow keys to highlight Line Coding.
a.
If the WPIM-DI is being configured for Frame Relay or if the
NI/DI Line Coding is B8ZS on the previous screen, press the
SPACE bar to select NONE, then press ENTER.
b. If the WPIM-DI is being configured for PPP and the NI/DI Line
Coding is AMI on the previous screen, press the SPACE bar to
select INV-HDLC, then press ENTER.
Содержание WPIM-DI
Страница 1: ...WPIM DI Local Management Guide 9031709 01 ...
Страница 2: ......
Страница 8: ...Contents vi WPIM DI Local Management Guide ...
Страница 28: ...Chapter 2 Local Management 2 16 WPIM DI Local Management Guide ...
Страница 32: ...Appendix A WPIM DI Specifications A 4 WPIM DI Local Management Guide ...