background image

Connecting to the Network

SWPIM-T1 Installation Guide

1-5

1.4

CONNECTING TO THE NETWORK

Figure 1-2

 depicts a typical configuration for the SWPIM-T1.

Figure 1-2

SWPIM-T1 Typical Configuration

1.5

COMPLETING THE INSTALLATION

After installation, the SWPIM-T1 will need to be configured for the 
network. Refer to the host platform software documentation in order to 
set up and manage the SWPIM-T1.

SSR-600

SWPIM-T1

Site 1

SSR-600

SWPIM-T1

Site 2

WAN Cloud

Содержание SWPIM-T1

Страница 1: ...SWPIM T1 LNK STS Title Page SWPIM T1 Installation Guide 9033058 01 ...

Страница 2: ......

Страница 3: ...tioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has bee...

Страница 4: ...f service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of th...

Страница 5: ...ly the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLICABLE LAW This Licen...

Страница 6: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3...

Страница 7: ...the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLIC...

Страница 8: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3...

Страница 9: ...LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the...

Страница 10: ...ed computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 ...

Страница 11: ...55022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ___________________________________ ___________________...

Страница 12: ...Notice x SWPIM T1 Installation Guide ...

Страница 13: ...packing the SWPIM T1 1 1 1 2 Installing the SWPIM T1 1 2 1 3 LANVIEW LED Indications 1 4 1 4 Connecting to the Network 1 5 1 5 Completing the Installation 1 5 APPENDIX A SPECIFICATIONS A 1 Physical Properties A 1 A 2 Network Interface A 1 A 2 1 Pinout for the T1 Interface Connector A 2 A 3 T1 Cable Assembly A 2 A 4 Environmental Requirements A 3 A 5 Regulatory Compliance A 3 APPENDIX B FCC PART 68...

Страница 14: ...Contents xii SWPIM T1 Installation Guide ...

Страница 15: ...2 3 data communications networks and their physical layer components is helpful before using the SWPIM T1 STRUCTURE OF THIS GUIDE This guide is organized as follows This Introduction provides preliminary information that will aid in using this manual lists technology and user s guides that may help the user to set up and manage the SWPIM T1 gives an overview of the SWPIM T1 and its features and in...

Страница 16: ...e SWPIM T1 using software The SWPIM T1 uses a single RJ48 connector supporting the T1 interface Refer to Appendix A for the Cabletron Systems part number and pin assignments for the T1 interface cable Internal CSU DSU The SWPIM T1 provides a T 1 interface that includes a built in Channel Service Unit Digital Service Unit CSU DSU for direct connection to a T 1 line This SWPIM supports both full T1 ...

Страница 17: ... SSR 600 Installation Guide HSIM SSR 600 Installation Guide 6C105 SmartSwitch 6000 Overview and Setup Guide Ethernet Technology Guide Cabling Guide The manuals referenced above can be obtained on the World Wide Web in Adobe Acrobat Portable Document Format PDF at the following site http www cabletron com Cabletron Systems applicable software manuals for the SSR 600 and the HSIM SSR 600 host platfo...

Страница 18: ...ns may be used in this document NOTE Note symbol Calls the reader s attention to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damage to the equipment Electrical Hazard Warning symbol Warns against an action that could result in personal injury or death d...

Страница 19: ...stems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers World Wide Web http www cabletron com Phone 603 332 9400 Internet mail support cabletron com FTP ftp...

Страница 20: ...Introduction xviii SWPIM T1 Installation Guide ...

Страница 21: ...IM T1 2 Attach the antistatic strap refer to the instructions in the antistatic wrist strap package before removing the SWPIM T1 from the antistatic packaging 3 Verify that the SWPIM T1 is undamaged Refer to Getting Help if there is any damage to the device Do not attempt to install the SWPIM T1 if it is damaged Only qualified personnel should install the SWPIM T1 CAUTION Failure to observe static...

Страница 22: ... the SWPIM T1 from the plastic bag Save the bag in the event the device must be removed from the host platform 5 Hold the SWPIM T1 with the faceplate facing away right side up from the host platform The 40 pin connector should be facing towards the empty slot with the wide part of the connector oriented down as shown in Figure 1 1 6 Locate the rail guides inside the slot in which the SWPIM T1 will...

Страница 23: ...1 must be configured before the WAN connection is made Once the SWPIM T1 has been configured the host platform must undergo a soft or hard restart in order for the SWPIM T1 to be recognized and for traffic to pass Refer to the appropriate software manual to configure the SWPIM T1 CAUTION Do not connect any WAN cables until the SWPIM T1 has been configured in software The phone company can shut dow...

Страница 24: ...nt to the far end Yellow Alarm Declared because of an incoming Yellow Signal from the far end Blue Alarm T1 Multiplexer failed or is disconnected CSU must send continuous unframed 1 s to the network Table 1 1 Link LED Color Indication Off Disabled or Not Configured Red Port is Active No Link Amber Transmit or Receive Traffic Green Port is Active Linked Blinking Green Port is in Test Mode Table 1 2...

Страница 25: ...uration for the SWPIM T1 Figure 1 2 SWPIM T1 Typical Configuration 1 5 COMPLETING THE INSTALLATION After installation the SWPIM T1 will need to be configured for the network Refer to the host platform software documentation in order to set up and manage the SWPIM T1 SSR 600 SWPIM T1 Site 1 SSR 600 SWPIM T1 Site 2 WAN Cloud ...

Страница 26: ...Chapter 1 Installation 1 6 SWPIM T1 Installation Guide ...

Страница 27: ...ns at any time without notice Pinouts and the T1 cable are also listed in this appendix A 1 PHYSICAL PROPERTIES A 2 NETWORK INTERFACE The connector for the RJ48 network port can be seen in Figure A 1 Figure A 1 RJ48 Pinout Dimensions 1 91 H x 5 40 W x 19 05 D cm 0 75 H x 2 125 W x 7 50 D in Weight Unit 0 068 kg 0 15 lb Nominal current draw on 5V supply from host platform 150 mA MTBF Predicted 10 1...

Страница 28: ...omer may specify the length of cable when ordering Table A 1 Pinouts for the T1 Interface Connection Pin Signal 1 Receive Ring 2 Receive Tip 3 Shield Ground 4 Transmit Ring 5 Transmit Tip 6 Shield Ground 7 Shield Ground 8 Shield Ground Table A 2 SWPIM T1 Cable Part Numbers Interface Cable Cabletron Part Number T1 Line Interface Cable 9372094 201 1 Standard 20 foot T1 Line Interface Cable T1 Line I...

Страница 29: ...to 40 C 41 to 104 F Non operating Temperature 30 to 90 C 22 to 194 F Operating Humidity 5 to 90 Non condensing Safety UL 1950 without D3 deviations CSA C22 2 No 950 and EN 60950 EMI FCC Part 15 Class A Electromagnetic Compatibility EMC Meets the EMC requirements of EN 50082 1 including IEC 801 2 ESD IEC 801 3 Radiated Susceptibility and IEC 801 4 EFT B NEBS TR NWT 000063 Network Equipment Building...

Страница 30: ...Appendix A Specifications A 4 SWPIM T1 Installation Guide ...

Страница 31: ...cted until it is repaired 4 The CSU DSU has been designed to prevent harm to the T1 network If the telephone company finds that the equipment is exceeding tolerable parameters the telephone company can temporarily disconnect service although they will attempt to give advance notice if possible 5 Under the FCC Rules no customer is authorized to repair this equipment This restriction applies regardl...

Страница 32: ...irs should be performed by our Company or an authorized agent It is the responsibility of the users requiring service to report the need for service to our Company or to one of our authorized agents Service can be obtained at Cabletron Systems Technical Support Address Cabletron Systems Inc 35 Industrial Way Rochester NH 03867 0505 Phone 603 332 9400 Internet mail support ctron com ...

Страница 33: ... equipment to be connected complies with Part 68 of the Commission s rules except for the encoded analog content and billing protection specifications With respect to encoded analog content and billing protection I attest that all operations associated with the establishment maintenance and adjustment of the digital CPE with respect to encoded analog content and encoded billing information continu...

Страница 34: ...uthorized representative using training materials and instructions provided by the manufacturer grantee of the equipment used to encode analog signals or c An independent training course e g trade school or technical institution recognized by the manufacturer grantee of the equipment used to encode analog signals or d In lieu of the proceeding training requirements the operator s maintainer s is a...

Отзывы: