Chapter 1: Installation
1-4
SWPIM-T1 Installation Guide
1.3
LANVIEW LED INDICATIONS
Refer to
Table 1-1
for the link LED indications for the SWPIM-T1.
Refer to
Table 1-2
for the status LED indications for the SWPIM-T1.
Red Alarm
Declared because of loss of signal, loss of framing, Alarm Indication
Signal. After a Red Alarm is declared, a Yellow Signal is sent to the
far-end.
Yellow Alarm
Declared because of an incoming Yellow Signal from the far-end.
Blue Alarm
T1 Multiplexer failed or is disconnected. CSU must send continuous
unframed “1”s to the network.
Table 1-1
Link LED
Color
Indication
Off
Disabled or Not Configured
Red
Port is Active, No Link
Amber
Transmit or Receive Traffic
Green
Port is Active, Linked
Blinking Green
Port is in Test Mode
Table 1-2
Status LED
Color
Indication
Off
Normal or Disabled
Red
Red Alarm
Amber
Yellow Alarm (RAI)
Blinking Amber
Loopback Test Mode
Blinking Green
Blue Alarm (AIS)
Содержание SWPIM-T1
Страница 1: ...SWPIM T1 LNK STS Title Page SWPIM T1 Installation Guide 9033058 01 ...
Страница 2: ......
Страница 12: ...Notice x SWPIM T1 Installation Guide ...
Страница 14: ...Contents xii SWPIM T1 Installation Guide ...
Страница 20: ...Introduction xviii SWPIM T1 Installation Guide ...
Страница 26: ...Chapter 1 Installation 1 6 SWPIM T1 Installation Guide ...
Страница 30: ...Appendix A Specifications A 4 SWPIM T1 Installation Guide ...