Chapter 5: Local Management
5-88
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
7.
Use the arrow keys to highlight the Errors field.
8.
Use the SPACE bar to select either the ON or OFF option and press
ENTER. ON forces the source module and port to forward errored
frames to the destination module(s) and port(s). OFF forces the
errored frames to be dropped before forwarding traffic.
9.
Use the arrow keys to highlight SAVE at the bottom of the screen.
Press ENTER. The message “SAVED OK” is displayed. This saves
the new settings and updates the Source Interface and Destination
Interface read-only fields.
NOTE
If more than one port is to be redirected, repeat steps 1 through
8 for each additional setting, then go to step 9 to save all the
new settings at once.