background image

Using LANVIEW

4-2

Troubleshooting

4.1.1

The LED Mode Switch

The SmartSwitches have an LED mode switch, located on the front panel, that allows the user to 
change the function of the LEDs. Refer to 

Figure 4-1

. The 6H202-24 and the 6H262-18 have the 

switch positioned near the bottom of the board. The 6H252-17 has the switch positioned near the 
top of the board. The switch functionality applies no matter where on the modules the switch is 
positioned. When the switch is in the UP position, the LEDs indicate the receive (RX) and transmit 
(TX) status of the fixed ports. When the mode switch is in the DOWN position, the LEDs indicate 
at what speed the applicable port is currently operating (10 Mbps or 100 Mbps) and if the 
applicable port is operating in standard or full duplex mode. 

Table 4-1

 provides the definitions of the LED states that occur when the LED mode switch is in the 

UP position. 

Table 4-2

 provides the definitions of the LED states that occur when the LED mode 

switch is in the DOWN position.

NOTE

The LED mode switch does not change the function of any LEDs on an HSIM or VHSIM 
installed in the 6H252-17. The GPIMs installed in the 6H262-18 will have the indications 
as listed starting in 

Table 4-4

.

Содержание SmartSwitch 6000

Страница 1: ...16X 10X 12X 9 10 11 12 14 13 15 16 17 18 19 20 21 22 23 24 18X 20X 22X 24X 2X 4X 6X 8X 1 2 3 4 5 6 7 8 6H262 18 FAST ENET DPX SPD RX TX LED MODE 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 16X 10X 12X 9 10 11 12...

Страница 2: ......

Страница 3: ...LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Cable...

Страница 4: ...case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for complia...

Страница 5: ...of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyrigh...

Страница 6: ...submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietar...

Страница 7: ...to regulation by agencies of the U S Government including the U S Department of Commerce which prohibit export or diversion of certain technical products to certain countries unless a license to expo...

Страница 8: ...cumentation and media CABLETRON DISCLAIMS ALL WARRANTIES OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTA...

Страница 9: ...he right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program...

Страница 10: ...e submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprieta...

Страница 11: ...andardization When operating within their performance limitations laser transceiver output meets the Class 1 accessible emission limit of all three standards Class 1 levels of laser radiation are not...

Страница 12: ...60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packag...

Страница 13: ...5 SmartTrunk 1 4 1 1 6 Remote Monitoring RMON 1 4 1 1 7 Broadcast Suppression 1 5 1 1 8 Port VLAN Redirect Functions 1 5 1 1 9 Rate Limiting 1 5 1 1 10 GARP Switch Operation 1 6 1 1 11 Flow Control 1...

Страница 14: ...3 5 3 6 Installing GPIMs 3 8 3 7 GPIM Network Connections 3 10 3 7 1 GPIM 09 Connection Using Multimode Cable 3 11 3 7 2 Connecting the GPIM 3 12 3 8 Completing the Installation 3 14 4 TROUBLESHOOTIN...

Страница 15: ...ifications 1000Base LX B 2 B 2 Physical and Environmental Specifications B 2 B 3 Regulatory Compliance B 3 C SWITCH SETTINGS UPGRADES AND INSTALLATIONS C 1 Setting the Mode Switches C 1 C 2 SIMM Upgra...

Страница 16: ...onnector 3 8 3 6 Installing a GPIM into the 6H262 18 3 9 3 7 Fiber Optic Port Designations 3 10 3 8 GPIM 09 Launch Mode Conditioning Cable Connection 3 11 3 9 Fiber Optic GPIM Connections 3 13 3 10 6H...

Страница 17: ...System Troubleshooting 4 9 4 6 Firmware Troubleshooting 4 10 4 7 Management System Troubleshooting 4 10 4 8 Device Setup Troubleshooting 4 11 A 1 COM Port Pin Assignments A 3 B 2 GPIM 01 Operating Ra...

Страница 18: ...xvi...

Страница 19: ...DE Read through this guide completely to understand the SmartSwitch module features capabilities and Local Management functions A general working knowledge of Fast Ethernet and IEEE 802 3 type data co...

Страница 20: ...artSwitches into the 6C105 SmartSwitch 6000 chassis Chapter 3 Installation provides instructions on how to install a module in the chassis and connect segments Chapter 4 Troubleshooting describes the...

Страница 21: ...F6 User s Guide HSIM FE6 User s Guide HSIM W6 User s Guide HSIM W84 User s Guide HSIM W87 User s Guide HSIM G01 G09 User s Guide VHSIM G6 User s Guide VHSIM A6DP User s Guide WAN Series Local Managem...

Страница 22: ...to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damag...

Страница 23: ...nks to networking technologies such as Gigabit Ethernet Fast Ethernet Fiber Distributed Data Interface FDDI Wide Area Network WAN and Asynchronous Transfer Mode ATM Some HSIMs can provide additional F...

Страница 24: ...SPD RX TX LED MODE 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 16X 10X 12X 9 10 11 12 14 13 15 16 G P I M 1 G P I M 2 COM CPU RESET 6H252 17 FAST ENET DPX SPD RX TX COM RESET CPU 2X 4X 6X 8X 1 2 3 4 5 6 7 8 14X 1...

Страница 25: ...lities are The Auto Negotiation feature targets the maximum capabilities that can be reached between the two devices For example the SmartSwitches adjust to 100 Mbps when the device on the other end o...

Страница 26: ...echnology together to scale the backbone bandwidth beyond the limitations of a single link All links are user configurable so administrators can scale the backbone bandwidth by adding SmartTrunk links...

Страница 27: ...ating as an 802 1Q switch Multiple VLANs can be directed to the same ports 1 1 9 Rate Limiting The Rate Limiting feature enables the SmartSwitch device to have control of traffic rates on a per port p...

Страница 28: ...flow of frames between two devices It ensures that a transmitting device does not overwhelm a receiving device with data This enables the receiving device to communicate with the transmitting device a...

Страница 29: ...ing any optional HSIM VHSIM or GPIM In the 802 1Q mode the default mode of operation the switch functions as an 802 1D switch until VLANs are configured SecureFast switching and IEEE 802 1Q switching...

Страница 30: ...6H262 18 are Gigabit Ethernet modules and are compliant with IEEE 802 3z The modules provide IEEE 802 1D Spanning Tree Algorithm STA support to enhance the overall reliability of the network and prote...

Страница 31: ...on of any action s already taken to resolve the problem e g changing mode switches rebooting the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A de...

Страница 32: ......

Страница 33: ...etwork performance 2 1 SmartTrunk To connect the SmartSwitch modules to a network so they can take advantage of the SmartTrunk feature there are certain rules concerning port connections and configura...

Страница 34: ...device at the other end of the fiber optic connection must meet the necessary 1000BASE SX or LX specification requirements for the devices to operate at 1 Gbps Refer to for cable specifications and Se...

Страница 35: ...Chassis Section 3 4 Connecting to the Network Section 3 5 Installing GPIMs Section 3 6 GPIM Network Connections Section 3 7 Completing the Installation Section 3 8 Only qualified personnel should inst...

Страница 36: ...or after the 6H262 18 is installed in the 6C105 chassis The GPIMs are hot swappable and therefore may also be installed even when the module has power applied Refer to Section 3 6 for installation and...

Страница 37: ...from the shipping box Save the box and packing materials in the event the module must be reshipped 3 Locate the antistatic wrist strap shipped with the 6C105 chassis Attach the antistatic wrist strap...

Страница 38: ...NOT install the module Immediately contact the Cabletron Systems Refer to Section 1 2 for details 1 2 3 4 5 PS1 PS2 Plastic Locking Tab Slot Number 2361 02 2159 01 Circuit Card Card Guides Metal Back...

Страница 39: ...100 ports with internal crossovers When connecting a workstation use a straight through cable When connecting networking devices such as another bridge repeater or router use a crossover cable Connect...

Страница 40: ...d green If the RX LED is OFF and the TX Transmit LED is not blinking amber perform the following steps until it is on a Verify that the LED mode switch located near the COM port of the module is in th...

Страница 41: ...onnection meets the dB loss and cable specifications outlined in the Cabletron Systems Cabling Guide Refer to the About This Guide preface for information on obtaining this document If a link is not e...

Страница 42: ...packaging 3 Hold the GPIM with the network connection port facing away from the 6H262 18 The 20 pin connector should be facing towards the empty GPIM slot with the wide part of the connector oriented...

Страница 43: ...the orientation against Figure 3 5 Push the GPIM back until the 20 pin port engages the GPIM The latch mechanism engages when the GPIM connector seats properly in the port Figure 3 6 Installing a GPI...

Страница 44: ...GPIM 01 and GPIM 09 both have the same type of SC fiber optic connector the directions for connectivity are the same except for when the GPIM 09 is connected to multimode fiber Refer to Section 3 7 1...

Страница 45: ...between like devices so that the transmit port of one device is connected to the receive port of the other device and vice versa If the fiber optic cable being used has SC style connectors that do no...

Страница 46: ...ber optic cable refer to Section 3 7 1 before following this procedure CAUTION The GPIM 01 and GPIM 09 use Class 1 lasers Do not use optical instruments to view the laser output The use of optical ins...

Страница 47: ...FF and the Transmit LED is not blinking amber perform the following steps until it is ON a Check that the device at the other end of the link is Gigabit Ethernet compatible and has power turned on b V...

Страница 48: ...s for troubleshooting before contacting Cabletron Systems Refer to Refer to Section 1 2 for details if the problem persists 3 8 COMPLETING THE INSTALLATION After installing the SmartSwitch and any opt...

Страница 49: ...stem called LANVIEW The LANVIEW LEDs Figure 4 1 allow quick observation of the network status to aid in diagnosing network problems Refer to Table 4 1 for a description of the LEDs Refer to the HSIM o...

Страница 50: ...the receive RX and transmit TX status of the fixed ports When the mode switch is in the DOWN position the LEDs indicate at what speed the applicable port is currently operating 10 Mbps or 100 Mbps an...

Страница 51: ...X 14X 16X DPX SPD RX TX LED Mode Switch DPX SPD RX TX DPX SPD RX TX LED MODE Mode Switch in UP Position Mode Switch in DOWN Position RESET A B B A LED functions when LED MODE switch is in the RX TX po...

Страница 52: ...tems Solid Testing If the LED remains amber for several minutes contact Cabletron Systems Green Solid Functional None Amber and Green Booting Blinks amber and green while booting None The following po...

Страница 53: ...nt User s Guide for information on enabling disabling ports 2 Contact Cabletron Systems Red Flashing Indicates collision rate None unless there is a high rate of activity If so check for network confi...

Страница 54: ...ED Descriptions for the 6H262 18 4 6 Troubleshooting 4 2 GPIM LED DESCRIPTIONS FOR THE 6H262 18 Figure 4 2 LANVIEW LEDs for the GPIM 2549_02 Receive RX G P I M 1 G P I M 2 Transmit TX Receive RX Trans...

Страница 55: ...lor Definition The following port RX and TX LED indications are only valid when the LED MODE switch is in the RX TX position Transmit Green Flashing Activity port enabled Amber Blinking Port in standb...

Страница 56: ...tP server on the network Press the RESET button on the front panel to attempt to use the firmware image in FLASH memory 2 If the problem continues after pressing the RESET button refer to Section C 1...

Страница 57: ...her free slot in the chassis 2 If the module functions in the selected slot the module s onboard power converter is operational The 6C105 chassis power bus may have a localized fault Install the modul...

Страница 58: ...ructions on how to force a download of a new firmware image 2 Contact Cabletron Systems if the problem continues Table 4 7 Management System Troubleshooting Possible Causes Instruction ImproperCommuni...

Страница 59: ...ered parameters to reset to factory default settings 1 Reenter the lost parameters as necessary Refer to your Local Management User s Guide for instructions on configuring the device through Local Man...

Страница 60: ...cessor goes through a reset process of approximately 60 seconds Additional downtime may be added as the module reenters the network CAUTION Pressing the RESET button resets the device and all current...

Страница 61: ...NS A 2 PHYSICAL PROPERTIES A 3 ENVIRONMENTAL REQUIREMENTS Processors Intel i960 RISC processor control Power PC Dynamic Random Access Memory DRAM 20 MB FLASH Memory 8 MB Shared Memory 4MB Dimensions 4...

Страница 62: ...ce Module HSIM or Very High Speed Interface Module VHSIM Slot accepts optional HSIMs or VHSIMs that provide a variety of physical cabling types Ports 1 through 24 Fast Ethernet 10 100 Mbps 100BASE TX...

Страница 63: ...c compatibility EMC requirements Table A 1 COM Port Pin Assignments Pin Signal Name Input Output 1 Transmit Data XMT Output 2 Data Carrier Detect DCD Output 3 Data Set Ready DSR Input 4 Receive Data R...

Страница 64: ......

Страница 65: ...and the GPIM 09 supports both multimode and single mode SMF fiber optic cable B 1 GIGABIT ETHERNET SPECIFICATIONS The following specifications for the Gigabit Ethernet GPIMs meet or exceed the IEEE 80...

Страница 66: ...inimum 11 5 dBm 11 5 dBm 9 5 dBm Receive Sensitivity 20 dBm 20 dBm 20 dBm Link Power Budget 8 5 dBm 8 5 dBm 10 5 dBm Table B 4 GPIM 09 Operating Range Modal Bandwidth 1300 nm Range 62 5 m MMF 500 MHz...

Страница 67: ...COMPLIANCE The GPIMs meet the following safety and electromagnetic compatibility EMC requirements Table B 7 GPIM Safety and EMC Requirements Eye Safety fiber optic GPIMs only FDA CDRH 21 CFR 1040 Clas...

Страница 68: ......

Страница 69: ...ered parameters such as the IP address and Subnet Masks to the SmartSwitch Default configuration settings Clear user entered passwords stored in NVRAM and restore the default passwords Figure C 1 show...

Страница 70: ...P server after power to the chassis is restored After changing the position of switch 6 and restarting the module the SmartSwitch requests a new image download until they either receive a new image or...

Страница 71: ...rade is available for the SmartSwitch modules to expand the DRAM to 32 MB This section explains how to locate and add replace a Single In line Memory Module SIMM For information on the available SIMM...

Страница 72: ...igure C 3 insert the SIMM down between the connector teeth 2 Pivot the SIMM downward so the connector clips align with the two side notches of the SIMM and the connector clips lock the SIMM into place...

Страница 73: ...ows the location of the two connectors for an optional High HSIM or VHSIM Depending on if an HSIM or VHSIM is installed one or both connectors are used Figure C 4 HSIM and VHSIM Connector Locations NO...

Страница 74: ......

Страница 75: ...Chassis Management 1 7 Document Conventions xx E Environmental requirements A 1 H Help 1 9 related manuals xix I Installation connecting to the Network 3 5 High Speed Interface Module C 5 Module 3 1 V...

Страница 76: ...utton 4 12 Runtime IP Address Discovery 1 3 S Safety A 3 Safety information laser ix SDRAM installation C 4 SIMMs installing LDRAM C 4 location C 3 SmartTrunk introduction 1 4 Specifications A 1 Stand...

Отзывы: