SmartSwitch ATM Switch Reference Manual 2-313
SSCOPConfig
SSCOPConfig
Use SSCOPConfig to set or display switch Service-Specific Connection-Oriented Protocol parameters. SSCOP
parameters control how the switch interoperates with other switches.
Note
The following applies to SmartSwitch 6500 only: You can hot-swap TSMs.
Hot-swapping is replacing a module when the chassis is powered up. If you
replace a TSM with another TSM of the same type (same I/O ports), existing
configuration of port parameters is not affected. This includes parameters set
using any of the following attributes: ATMRoute, CACServiceClassBw,
IlmiConfig, NetPrefix, Port, PortConfig, PVC, PVP, ServiceRegistry, SigTimer,
SigStatistics, SSCOPConfig, and SSCOPStatistics. If you replace a TSM with
another TSM of a different type, existing configuration of port parameters is
deleted. The deletion occurs when the new module is plugged into the chassis
backplane.
Operators
modify, show
Parameters
Input Parameter
Description
Value/Field Size
Default
[PortNumber]
Port number on the switch.
You can specify a physical
or virtual port.
A1 to B4 (physical-2500 family),
A1.n to B4.n (virtual-2500 family),
1A1 to 8B4 (physical-6500),
1A1.n to 8B4.n (virtual-6500),
or All
[MaxPD]
Number of SD PDUs after
which a Poll PDU is
generated.
5-20
20
[MaxCC]
Number of BEGIN PDUs
sent during line
establishment.
4-10
4
[PollTime]
Time (in milliseconds)
between generation of Poll
PDUs.
100-1000
750
Содержание SmartSwitch 2500
Страница 28: ...1 14 SmartSwitch ATM Switch Reference Manual List of Operators and Switch Attributes Introduction...
Страница 376: ...3 8 SmartSwitch ATM Switch Reference Manual swms Command Boot Load Commands...
Страница 388: ...A 12 SmartSwitch ATM Switch Reference Manual Acronyms...
Страница 392: ...B 4 SmartSwitch ATM Switch Reference Manual Event Alarm Messages...