2-18 SmartCell 6A000/ZX-250 Reference Manual
Console Commands
BUSStat
Use BUSStat (broadcast and unknown server statistics) to view statistics that the BUS maintains for each ELAN.
Operators
show, clear
Parameters
Input Parameter
Description
Value/Field Size
Default
[ELANNumber]
Number of the ELAN to which the BUS belongs.
0-127
ALL
Output Parameter
Description
[Out Octets]
Number of octets (bytes) the BUS has sent since its initialization.
[Out Unicast]
Number of unicast frames forwarded by the BUS.
[Out Multicast]
Number of multicast frames forwarded by the BUS.
[In Octets]
Number of octets (bytes) the BUS has received since its initialization.
[In Unicast]
Number of unicast frames received by the BUS.
[In Multicast]
Number of multicast frames received by the BUS.
[Frame Timeouts]
Number of frames dropped by the BUS due to timeout.
[VCC Rejects]
Number of frames rejected because VCC is not available.