9T125-24 Module Specific Information
Exiting the Port Configuration Screen
To exit the Token Ring Port Configuration Screen, use the arrow keys to highlight
RETURN
, then press the Return key.
Table 4. Token Ring Port Operational Codes
If the port is a...
And if the port is
administratively
turned...
Then, the operational status is:
Lobe Port
ON
INS
(Inserted - Phantom link is detected)
The station port is on and is inserted into the ring.
ENB
(Enabled - No phantom link is detected)
The station port is on, but it is not inserted into the
ring.
OFF
LNK
(Linked - Phantom link is detected)
The station port is off; the station is trying to gain
access to the ring.
BYP
(Bypassed - No phantom link is present)
The station port is off and the station is not attempting
to access to the ring.
ON or OFF
FLT
(Speed Fault)
The ring speed of the port is in conflict with the ring
speed of the designated token ring. The port will
remain in bypass.