The Signalling Screen
HSIM-A6DP User’s Guide
3-49
3.15.7
Setting the UNI Version
To set the UNI Version manually, perform the following steps:
1.
Use the arrow keys to highlight the ILMI Status field.
2.
Press the SPACE bar until the option [Enabled] displays.
3.
Use the arrow keys to highlight the UNI Version field.
4.
Press the SPACE bar to toggle between the selections [UNI3.0] and
[UNI3.1].
5.
With the desired UNI version displayed, use the arrow keys to
highlight the SAVE command and press ENTER.
6.
Use the arrow keys to highlight the RESTART UNI command at the
bottom of the screen and press ENTER.
7.
The new version of UNI is now operational.
!
CAUTION
Before completing the following step, ensure that this caution is
fully understood. By restarting UNI, ALL SVCs currently
operating on the HSIM-A6DP will be lost.