background image

 

Page 1 - 8

 

INTRODUCTION

 

1.4

TECHNOLOGY OVERVIEW

1.4.1

100 Megabit/Second FDDI Over Copper

 

The migration of FDDI fiber optic technology to twisted pair 
copper wire began with the desire to utilize inexpensive, and 
previously installed twisted pair cable as a replacement for more 
expensive vendor-specific media. 

There are many benefits to be gained from operating FDDI 
technology on twisted pair cable: increased bandwidth, 
elimination of rewiring costs, reduced cost of new installations, 
and simpler and less expensive transceivers.

In pursuit of these goals, Cabletron Systems is participating in the 
standards process with the American National Standards Institute 
(ANSI), creating a draft standard for the transmission of 100 Mb/s 
FDDI data over twisted pair copper wire. The new standards, 
Twisted Pair - Physical Media Dependent (

 

TP-PMD

 

) and Shielded 

Twisted Pair - Physical Media Dependent (

 

STP-PMD

 

) define the 

minimum performance requirements for both shielded and 
unshielded twisted pair cable. The guidelines for the new standard 
are set forth below:

Transmit distance of 100 meters for both UTP and STP cable.

The same Bit Error Rate as FDDI over fiber cable (2 x 10

 

-1

 

).

FCC Class A (commercial) certification.

European EN55022 Class A (commercial) certification.

UTP - Category 5 cable (as specified in EIA/TIA TSB-36).

STP - Type 1, individually and overall shielded, 150 ohm cable.

Содержание F3019

Страница 1: ...C A B L E T R O N S Y S T E M S I N C Desktop Network Interface Products INSTALLATION GUIDE for F3019 F3059 F3069 F3079 F7019 F7059 F7069 and F7079 FDDI ADAPTERS ...

Страница 2: ...P N 9030826 01 December 1993 35 Industrial Way P O Box 5005 Rochester New Hampshire 03867 0505 ...

Страница 3: ... HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES VIRUS DISCLAIMER Cabletron has tested its software with current virus checking technologies However because no antivirus system is 100 reliable we strongly caution you to write protect and then verify that the Licensed Software prior to installing it is virus free with an anti virus system in which you have confidence ...

Страница 4: ...perator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority t...

Страница 5: ...ntenance checks or adjustments The output is factory set and does not allow any user adjustment Class 1 Laser transceivers comply with the following safety standards 21 CFR 1040 10 and 1040 11 U S Department of Health and Human Services FDA IEC Publication 825 International Electrotechnical Commission CENELEC EN 60825 European Committee for Electrotechnical Standardization When operating within th...

Страница 6: ...2 6 dBm or 55 x 10 6 watts Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port The maximum radiance from the optical port under worst case conditions is 0 8 W cm 2 or 8 x 103 W m2 sr 1 Do not use optical instruments to view the laser output The use of optical instruments to view laser output increases eye hazard When viewing the output ...

Страница 7: ...SE FOR A FULL REFUND CABLETRON SOFTWARE PROGRAM LICENSE 1 LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS...

Страница 8: ...MITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU UNITED STATES GOVERNMENT RESTRICTED RIGHTS The enclosed product a was developed solely at private expense b contains restricted computer software submitted with restricted rights in accordance with section 5...

Страница 9: ...Preparing the Adapters 2 2 2 4 Installing the Adapters 2 2 2 4 1 Installing the F30XX Model Adapters 2 3 2 4 2 Copying the ADF File 2 5 2 4 3 Installing the F70XX Model Adapters 2 6 2 5 LANVIEW LEDs 2 7 2 5 1 Using LANVIEW LEDs 2 8 2 6 Loading Network Software 2 9 2 7 Troubleshooting Checklist for Adapters 2 9 CHAPTER 3 NETWORK CONNECTIONS 3 1 Optical Fiber Connections 3 1 3 1 1 Twisted Pair FDDI ...

Страница 10: ...iii CONTENTS APPENDIX A FDDI MEDIA SPECIFICATIONS A 1 Multimode Fiber Optics A 1 A 2 Multimode Fiber Optic Interface A 2 A 3 Single Mode Fiber Optics A 3 A 3 1 Twisted Pair for FDDI Over Copper A 4 INDEX ...

Страница 11: ...ities of the Cabletron Systems FDDI network adapters 1 1 USING THIS MANUAL This manual is structured so that you can follow sequential chapters as you install and test the Cabletron FDDI network adapters Chapter 1 Introduction discusses the capabilities of the Cabletron Systems FDDI network adapters A Technology Overview explains briefly the technology of transmission of FDDI Over Copper twisted p...

Страница 12: ...The operating system and version number that you are using i e MS DOS Version 5 0 OS 2 Version 2 0 etc The make and model of any other add in cards in your system and the version number of any associated software You can contact Cabletron Systems Technical Support by Phone 603 332 9400 FAX 603 337 2444 Specify Document No 1101 listing of latest driver releases sample configurations and key words B...

Страница 13: ...100 Megabit unshielded twisted pair network F3059 The Cabletron Systems F3059 FDDI adapter has the same characteristics as the F3019 above except that it is configured for shielded twisted pair cable Table 1 1 Adapter Types and Media Adapter Type Bus Interface Media F3019 Micro Channel FDDI Over Copper unshielded twisted pair F3059 Micro Channel FDDI Over Copper shielded twisted pair F3069 Micro C...

Страница 14: ...to an ANSI Standard X3T9 5 Multimode Fiber Distributed Data Interface network F3079 The Cabletron Systems F3079 FDDI adapter connects your Micro Channel compatible computer to an ANSI Standard Single Mode Fiber Distributed Data Interface network F7079 The Cabletron Systems F7079 FDDI adapter connects your EISA Bus compatible computer to an ANSI Standard Single Mode Fiber Distributed Data Interface...

Страница 15: ...from another workstation utilizing Cabletron Systems Remote LANVIEW for Windows Remote LANVIEW for SunNet Manager or SPECTRUM Through this software you can gather statistics on the adapter s activity on the FDDI network For further information on gathering network adapter statistics from another workstation refer to the appropriate network management manual 1 3 4 LANVIEW LEDs The FDDI network adap...

Страница 16: ...hipset Data Transfer 32 bit bus master supports burst mode transfers on compatible machines Buffer Memory One megabyte LED Indicators Processor LED Red flash rate indicates processor status 1 flash sec for 30 sec Processor OK steady red Adapter Failure Transmit Green FDDI Output Receive Yellow FDDI Input Link Status Bicolor LED Red No Connection Green Link Valid Unlit Signal Detect No Link Diagnos...

Страница 17: ... 8 7 µm 125 µm graded index fiber cable FDDI Over Copper 100 meters using shielded or unshielded twisted pair cable Netwk Interface Multimode Single Mode Fiber Type S FDDI Media Interface Connector Connectors are keyed for Single Attached Station Dual Attach Station Dual Homing configuration implemented through a daughter board connection FDDI Over Copper uses industry standard RJ 45 twisted pair ...

Страница 18: ...rticipating in the standards process with the American National Standards Institute ANSI creating a draft standard for the transmission of 100 Mb s FDDI data over twisted pair copper wire The new standards Twisted Pair Physical Media Dependent TP PMD and Shielded Twisted Pair Physical Media Dependent STP PMD define the minimum performance requirements for both shielded and unshielded twisted pair ...

Страница 19: ...nces up to 100 meters and data rates up to 100 Mb s Two Technical System Bulletins TSB were issued by EIA TIA after ANSI EIA TIA 586 TSB 36 classifies UTP cables into categories 3 4 and 5 and provides characteristic and performance values at particular data rates TS8 40 classifies connector hardware punch down blocks patch panels wall jacks etc into categories 3 4 and 5 and also provides character...

Страница 20: ...Page 1 10 INTRODUCTION ...

Страница 21: ...ork adapters is simple and straightforward The network adapters are software configurable they have no jumpers or switches 2 2 UNPACKING THE ADAPTERS The FDDI network adapter and software are shipped separately The hardware package should contain one box with an FDDI network adapter and this manual The shrink wrapped software package contains a Network Software Installation Guide the software disk...

Страница 22: ...manual that came with your computer for more detailed information on installing adapters in Micro Channel and EISA Bus architectures Figure 2 1 Nomenclature F30XX and F70XX Model Adapters The network adapters are sensitive to static discharges Hold the adapter by the top of the metal bracket and the opposite top corner Avoid contact with the computer bus edge connector or any of the adapter s comp...

Страница 23: ... F30XX Model Adapters To install an F30XX model FDDI adapter in your computer follow these instructions Turn off the power to the PC and peripherals and disconnect all power cords and cables Remove the computer cover and select the slot your adapter will be installed in The F30XX adapter can occupy any unused Micro Channel style 32 bit expansion slot If you have not already done so remove the adap...

Страница 24: ...t faces out the back of the computer as shown Align the adapter so the computer bus edge connector is lined up with the expansion slot 4 Figure 2 3 Slide the adapter into the guide slots and firmly press but do not force the adapter into the expansion slot In most Micro Channel machines the plastic clips on the F30XX Micro Channel adapter 1 5 Figure 2 3 will snap into place as the adapter is inser...

Страница 25: ... of the Reference Diskette when you perform the following procedure To configure the ADF Copy the ADF file 0070 ADF from the Cabletron software diskette to the IBM Reference Diskette copy Follow the instructions in your computer user s manual to access the system Setup utility In your system Setup Menu find the entry that lets you update the system configuration files When asked insert the IBM Ref...

Страница 26: ...r computer use the procedure that follows From the Cabletron software diskette copy the EISA configuration file CSI06090 CFG onto a copy of your system configuration diskette Using your computer s EISA configuration program follow the instructions in your computer user s manual for installing a new adapter When prompted select the Bus Master slot that you wish to install the adapter in Follow the ...

Страница 27: ...EW LEDS The FDDI network adapters incorporate Cabletron Systems built in LANVIEW visual diagnostic and status monitoring LEDs The LANVIEW LEDs shown in Figure 2 4 are more effective than a network monitor because network troubleshooting personnel can quickly scan the LEDs to diagnose network problems and determine which network segment is faulty Figure 2 4 LANVIEW LEDs Processor red Receive Data y...

Страница 28: ...n the Processor LED is on continuously not flashing it indicates adapter failure Reload the network driver to cause the SMT code to be updated If the continuous indication persists contact Cabletron Technical Support Receive Data yellow The Receive Data LED illuminates to indicate that packets are being received from the FDDI network Transmit Data green The Transmit Data LED illuminates when packe...

Страница 29: ...accompanied the adapter The drivers are grouped in subdirectories that contain readme files to explain recent changes in procedure etc The Network Software Installation Guide included with the Cabletron software diskette s contains detailed instructions for installing network drivers 2 7 TROUBLESHOOTING CHECKLIST FOR ADAPTERS Make sure the adapter is installed and properly seated in the computer s...

Страница 30: ...onnection to a server or a host cannot be maintained check the cable first with a test set After verifying the cable check the device that you are trying to communicate with Verify that you can contact it or that other clients can contact it ...

Страница 31: ...on DAS as defined in the ANSI X3T9 5 specification Dual Attach Station configuration is implemented by the use of a daughter board Instructions for installing the daughter board are provided in this chapter The FDDI adapter connects to the FDDI ring via a type S FDDI connector located on the rear facing bracket of the adapter Remove the protective cover from the duplex shroud end of the FDDI cable...

Страница 32: ...The RJ 45 pinout configuration for Unshielded Twisted Pair UTP and Shielded Twisted Pair STP Physical Layer Medium Dependent PMD ports is shown below Figure 3 2 RJ 45 TP PMD Port Pinouts FDDI Cable Locking Latches both sides FDDI Connector FDDI Cable Insertion Key Bracket 1 Transmit Transmit Receive Receive ...

Страница 33: ... cannot establish a link to the FDDI network recheck your FDDI cable connections and observe the red Processor LED on the adapter If this LED is illuminated continuously there is a processor failure Reload the network driver which will automatically download the SMT management microcode If this condition persists call Cabletron Technical Support 3 2 1 Network Requirements Specifications When conne...

Страница 34: ...h Station DAS Dual Attach Station DAC Dual Attach Concentrator SAC Single Attach Concentrator FDDI devices are physically attached to the ring using fixed shroud duplex FSD media interface connectors Four connectors are defined in the X3T9 5 FDDI Standard Physical Layer the PMD Physical Media Dependent standard They provide proper alignment of the trunk fibers for each of the valid configurations ...

Страница 35: ...e The type S connector has a wide centrally located keyway and is considered a non precision connector for use at the station end of an SAS lobe cable Figure 3 3 FDDI Connector Types shows the configurations of the four types of media interface connectors For a more detailed description of FDDI network characteristics and configurations please read the ANSI X3T9 5 specification Type B FDDI RECEPTA...

Страница 36: ...r board provides the additional FDDI connectors and ancillary circuitry for Dual Attach Station operation The daughter board obtains its power from the bus slot it is plugged into Figures 3 4 and 3 5 provide instructions for installing the daughter board and connecting the daughter board to the FDDI adapter Figure 3 4 Installing a Daughter Board LANVIEW LEDs Connectors for Daughter Board Cables FD...

Страница 37: ...acket of the adapter If you have not done so remove the daughter board from its protective pouch and visually inspect it Refer to the installation procedures for the FDDI adapters in Chapter 2 Section 2 4 1 Installing the F30XX Model Adapters and Section 2 4 3 Installing the F70XX Model Adapters Install the daughter board as you would the respective model adapter in a slot adjacent to the adapter ...

Страница 38: ...DDI cables to adapter and daughter board according to the FDDI ring configuration Consult the ANSI X3T9 5 specification for a description of Dual Attach Station FDDI ring topology After connecting the adapter and daughter board to the FDDI ring observe the LANVIEW LEDs see Section 2 5 to determine the status of the adapter and the FDDI ring Alignment Keys Alignment Keys Ribbon Cables FDDI Adapter ...

Страница 39: ...ble segment 16 0 dB or less for a 62 5 125 µm fiber cable segment 19 0 dB or less for a 100 140 µm fiber cable segment Fiber Optic Budget The fiber optic budget and total network propagation delay should be calculated before fiber runs are incorporated in any network design Fiber optic budget is the combination of optical loss of the fiber optic cable in line splices and fiber optic connectors Pro...

Страница 40: ...Value Worst Case Worst Case Budget Typical Budget Receive Sensitivity 30 5 dBm 28 0 dBm Peak Input Power 7 6 dBm 8 2 dBm Transmitter Power 50 125 µm fiber 13 0 dBm 15 0 dBm 13 0 dB 17 5 dB 62 5 125 µm fiber 10 0 dBm 12 0 dBm 16 0 dB 20 5 dB 100 140 µm fiber 7 0 dBm 9 0 dBm 19 0 dB 23 5 dB Error Rate Better than 10 10 bit error rate ...

Страница 41: ...ngle Mode Fiber Optics Single Mode Fiber Specification Core Diameter 8 7 µm 0 5 µm Cladding Diameter 127 0 µm maximum 123 0 µm minimum Cable Attenuation 0 5 dB km typical Cable Length 40 km 24 miles station to station Max Total Length 100 km 62 miles Dual Ring 200 km 124 miles wrapped Optical Wavelength 1305 nanometers typical Spectral Width 15 nanometers maximum Optical Risetime 2 nanoseconds Opt...

Страница 42: ...ission is specified in EIA TIA TSB 36 TSB 40 Table A 3 below lists these cable specifications Table A 3 Twisted Pair Specifications for FDDI Over Copper Cable Connector Category 5 Maximum Total Cable Length 100 km 62 miles Dual Ring 200 km 124 miles wrapped Maximum Twisted Pair Length Between Adjacent Nodes 100 meters 328 1 feet ...

Страница 43: ...eatures 1 3 F7069 FDDI adapter connectivity 1 4 features 1 3 F7079 FDDI adapter connectivity 1 4 FDDI adapter features 1 3 LANVIEW LEDs 1 5 software 1 5 statistics 1 5 FDDI media specifications A 1 multimode fiber optic interface A 2 multimode fiber optics A 1 attenuation A 1 cable A 1 fiber optic budget A 1 length A 1 single mode fiber optics A 2 cable A 3 G Getting help 1 2 BBS 1 2 FAX 1 2 phone...

Страница 44: ...LEDs 2 8 transmit data 2 8 Loading network software 2 9 N Network connections 3 1 checking network connections 3 3 connecting the adapter to the FDDI ring 3 1 optical fiber 3 1 twisted pair FDDI 3 2 Network requirements specifications 3 3 FDDI station configurations 3 4 S Safety information iii laser iii Software 1 5 Statistics 1 5 T Technical specifications 1 6 Technology overview FDDI over coppe...

Отзывы: