background image

Chapter 3: DLM6C-AA Setup

3-6

DLM6C-AA Overview and Setup Guide

3.2.5

Installing a Power Supply Module

You must install at least one power supply in the DLM6C-AA chassis. 
One power supply provides sufficient power for most module 
configurations but a second power supply can be installed to provide a 
redundant, load-sharing power source. When two power supplies are 
installed, the load is evenly distributed. If one power supply fails for any 
reason, the second power supply assumes the load.

The DLM6C-AA power supplies must be installed in the two slots labeled 
PS1 and PS2 on the far right side of the chassis (

Figure 3-4

). If you intend 

to install a single power supply it must be installed in the slot labeled PS1 
in the chassis. A flat blade screwdriver is needed to install the power 
supply modules.

To install the power supplies into the DLM6C-AA chassis, refer to 

Figure 3-4

 and proceed as follows:

1.

Unpack the power supply by removing it from the shipping box and 
sliding the two foam end caps off the unit. (Save the shipping box and 
materials in the event the unit must be reshipped.)

2.

Remove the power supply from its protective plastic bag. (Save the 
shipping box and materials in the event the unit must be reshipped.)

3.

Examine the power supply carefully, checking for damage. If any 
damage is noted, DO NOT install the power supply. Contact your 
DIGITAL representative immediately.

!

If the DLM6C-AA is configured with a single power supply 
module, it must be located in slot PS1.

Содержание DLM6C-AA

Страница 1: ...DIGITAL MultiSwitch 700 DLM6C AA Overview and Setup Guide...

Страница 2: ......

Страница 3: ...700 DLM6C AA Overview and Setup Guide Part Number 9032610 September1998 This guide describes how to install and configure the DIGITAL MultiSwitch 700 DLM6C AA chassis Revision Update Information This...

Страница 4: ...es United States Government Restricted RightsUnited States Government Restricted Rights The enclosed product a was developed solely at private expense b contains restricted computer software submitted...

Страница 5: ...io Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques d...

Страница 6: ...terpreted and governed under the laws and in the state and federal courts of New Hampshire You accept the personal jurisdiction and venue of the New Hampshire courts EXCLUSION OF WARRANTY AND DISCLAIM...

Страница 7: ...60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packag...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...EQUIREMENTS AND SPECIFICATIONS 2 1 Site Guidelines 2 1 2 2 Configuration Guidelines 2 2 2 3 Operating Specifications 2 2 2 3 1 Physical Specifications 2 3 2 3 2 Power Supply Requirements 2 4 2 4 LEDs...

Страница 12: ...LM6C AA with an AC Power Supply 3 11 3 4 Powering Up a DLM6C AA with a DC Power Supply 3 11 3 4 1 Connecting an HA205 MD to 48 60 Vdc Source 3 13 3 5 Removing and Reinstalling the Fan Tray 3 14 3 5 1...

Страница 13: ...elpful when setting up the DLM6C AA chassis STRUCTURE OF THIS GUIDE This guide is organized as follows Chapter 1 Introduction discusses the features and capabilities of the DLM6C AA Chapter 2 Installa...

Страница 14: ...configure the modules using Local Management after installation is complete Specifications for all modules are included in each manual Each manual in this set assumes that the qualified personnel ins...

Страница 15: ...g have the following information ready A description of the failure A description of any action s already taken to resolve the problem e g changing mode switches rebooting the unit etc A description o...

Страница 16: ......

Страница 17: ...en k nnten DANGER D conseille l utilisateur d ex cuter une action pouvant entra ner des dommages mat riels corporels voire m me la mort AVISO Previene contra una acci n que podr a da ar el equipo prov...

Страница 18: ...appar eil sont r serv es un personnel qualifi AVISO S lo el personal cualificado debe instalar o dar mantenimiento a esta unidad WARNING If theDLM6C AA is to be placed on a shelving unit the shelf mus...

Страница 19: ...epter un poids de 34 kg Si l appareil doit tre mont sur un rack assurez vous que celui ci est pr vu pour cela et qu il restera stable une fois l appareil install Si le rack n est pas fix au sol il est...

Страница 20: ...tung des Verzweigungsstromkreises auf mindestens 25 A eingestellt ist Verwenden Sie nur 10 AWG Kupferhalbleiter Ein genehmigtes leicht zug ngliches Trennger t mit angemessener Strom und Spannungsleist...

Страница 21: ...o las autoridades competentes WARNING To prevent injury or damage to the equipment remove power from a 48 60 Vdc power source before connecting to an HA205 MD dc power supply VORSICHT Um Verletzungsg...

Страница 22: ...ht zu besch digen stellen Sie sicher da das Modul gerade eingeschoben und vorsichtig eingesetzt wird ATTENTION Pour viter d endommager les connecteurs du backplane lors de l tape suivante veillez ce q...

Страница 23: ...rens alle diesbez glichen Vorsichtsma nahmen Bei Nichtbeachtung k nnte das Ger t besch digt werden ATTENTION L appareil DLM6C AA ou le module h te sont sensibles l lectricit statique Au cours de cette...

Страница 24: ......

Страница 25: ...s power supplies fan tray and modules are installed from the front of the chassis for ease of maintenance All LED indicators are observable from the front of the chassis to aid in monitoring network o...

Страница 26: ...s without interruption to network traffic Power Supply LANVIEW LEDs Each power supply module comes equipped with LEDs for at a glance diagnostics that indicate individual power supply status and overa...

Страница 27: ...ut powering down the chassis and interrupting network traffic The DLM6C AA Cooling System The DLM6C AA features a removable fan tray that is accessible from the front of the unit This unit is hot swap...

Страница 28: ......

Страница 29: ...ithin the rack there must be 3 inches of clearance above the unit and 2 inches of clearance on either side of the unit If the DLM6C AA is to be placed on a shelving unit the shelf must be able to supp...

Страница 30: ...the capability to configure the module and access chassis power supply and fan tray information These modules are also SNMP compliant to allow remote management through SNMP software such as the Cable...

Страница 31: ...D Power Supply HA205 AA Power Supply H3105 AA Fan Tray Dimensions 62 23 H x 44 04 W x 35 56 D cm 24 5 H x 17 34 W x 14 D in Weight with factory installed fan tray 11 7 kg 26 lb Dimensions 44 63 H x 6...

Страница 32: ...d definitions of the LEDs for the DLM6C AA power supply modules and fan tray unit 2 4 1 Power Supply LEDs There are two LEDs on the power supply Table 2 1 describes the different states of the power s...

Страница 33: ...Power Green All outputs and input of the power supply are within regulation Red Any output or input of the specific power supply is out of regulation REDUNDANCY Green Redundancy is available Amber Red...

Страница 34: ...ED and their definitions Refer to Figure 2 2 for the location of the fan tray LED Figure 2 2 Fan Tray LED Table 2 2 Fan Tray LED States and Their Definitions LED Color Status Green All fans are operat...

Страница 35: ...from the shipping box Save the shipping box and materials in the event the chassis has to be reshipped 2 Remove the chassis from the protective plastic bag Save the bag in the event the unit must be...

Страница 36: ...hat must be followed to complete the installation of the DLM6C AA 3 2 1 Installation Order Once a suitable site has been chosen the DLM6C AA can be installed The chassis can be freestanding or rack mo...

Страница 37: ...there are four screws inside the bag with the cable management bar 2 Refer to Figure 3 1 Line up the two holes on each side of the cable management bar with the two holes located underneath the DLM6C...

Страница 38: ...e the DLM6C AA to the rack starting with the bottom holes and working up as shown in Figure 3 2 Figure 3 2 Rack Mounting the DLM6C AA If the rack is not secured to the floor it is recommended that the...

Страница 39: ...r modules In addition observe all precautions when handling these modules to prevent damage from ESD Place the wrist strap on your wrist and plug the other end into the grounding receptacle at the top...

Страница 40: ...install a single power supply it must be installed in the slot labeled PS1 in the chassis A flat blade screwdriver is needed to install the power supply modules To install the power supplies into the...

Страница 41: ...ntil it is connected to the backplane with the front panel flush with the face of the DLM6C AA Do not force the module into place If significant resistance is encountered before the front panel is flu...

Страница 42: ...up however DIGITAL recommends that installation of all modules for the DLM6C AA be completed before powerup Refer to the following sections to complete the installation 1 2 3 4 5 PS1 PS2 Slotted Screw...

Страница 43: ...e plastic bag Save the bag in the event the module must be reshipped Observe all precautions to prevent damage from ESD 5 Examine the module for damage If any damage exists DO NOT install the module C...

Страница 44: ...4 5 PS1 PS2 Plastic Locking Tab Slot Number LKG 10803 98F Circuit Card Card Guides Metal Back Panel Plastic Locking Tab Backplane Connector MultiSwitch 700 TM TM DLM6C AA TM HA205 AA TM HA205 AA H310...

Страница 45: ...eceived from the power supply modules fan tray LED will be green If you experience any problems during the installation of the DLM6C AA contact your DIGITAL representative for assistance 3 4 POWERING...

Страница 46: ...ARDS CONNECT TO A RELIABLY GROUNDED 48 60 VDC SELV SOURCE ENSURE THE BRANCH CIRCUIT OVERCURRENT PROTECTION IS RATED AT A MINIMUM OF 25 A USE 10 AWG SOLID COPPER CONDUCTORS ONLY ENSURE THAT A READILY A...

Страница 47: ...Source To connect the HA205 MD to a 48 60 Vdc power source face the front of the power supply then refer to Figure 3 7 and proceed as follows Figure 3 7 48 60 Vdc Power Supply Connections 1 Connect th...

Страница 48: ...1 Removing the Fan Tray To remove the fan tray refer to Figure 3 8 and proceed as follows 1 Locate the ESD wrist strap shipped with the DLM6C AA Attach the wrist strap to your wrist and plug the cabl...

Страница 49: ...to Figure 3 9 and proceed as follows 1 Locate the ESD wrist strap shipped with the DLM6C AA Attach the ESD wrist strap to your wrist and plug the cable from the ESD wrist strap into the ESD grounding...

Страница 50: ...red for a moment after the power switch is turned on and then change to green to indicate that all fans are operating properly If this LED remains red it indicates that one or more of the fans are no...

Страница 51: ...and Reinstalling the Fan Tray DLM6C AA Overview and Setup Guide 3 17 Figure 3 9 Reinstalling the Fan Tray Slot Guides Slotted Screws 2 1 2 3 4 5 PS1 PS2 LKG 10807 98F MultiSwitch 700 TM TM DLM6C AA H...

Страница 52: ......

Страница 53: ......

Страница 54: ...9032610 Printed in U S A...

Отзывы: