ONNECTIVITY

Connecting a Workgroup Product to a CSX100 via PPP

c.

Under AppleTalk Port Information, configure a WAN UnNumbered port:

Select the WAN UnNumbered port type.

d. Under AppleTalk Static Routes, configure a static route to Central:

Enter Extended for Central’s network type (the default).

Enter 10-13 as the destination network range (Central’s network range).

Enter 0.0 as the next hop (it’s over an unnumbered link).

Enter Central as the next hop’s device name.

Enter 2 as the number of hops for this route.

Enter Engineering as Central’s default zone name.

Enter Marketing as Central’s second zone name.

4.

Under Security, select System Options and Information, then under System Information:
a.

Set your System Name (Remote). This matches up with Remote device information 
configured on Central.

b.

Set your System Secret (Remote_S). This matches up with Remote device information 
configured on Central.

C

ONNECTING

 

A

 W

ORKGROUP

 P

RODUCT

 

TO

 

A

 CSX100 

VIA

 PPP

In this section, we describe the configuration steps required for connecting a workgroup product 
to a CSX100 via PPP. Separate instructions are included for two router-to-router applications, 

IP

 

and 

IPX

, and two router-to-bridge applications, 

IPX

 and 

AppleTalk

.

The documentation assumes that you are able to run QuickSET and have it find your CSX100. If 
you are unable to run QuickSET, please refer to the Read Me First document on the CyberSWITCH 
100 Family with QuickSET CD-ROM.

IP R

OUTER

 

TO

 IP R

OUTER

 

WITH

 N

ETWORK

 A

DDRESS

 T

RANSLATION

 C

ONFIGURATION

With Network Address Translation (NAT), the CSX100 has one real IP address on the WAN and 
you can create your own IP addresses on the LAN. Using DHCP, you can create any range of 
addresses for the PC’s on the LAN to use. When a PC requests to access the WAN, the CSX100 
sends its own valid WAN IP address instead of the address on the PC. The outside world is 
unaware of the IP addresses used on the LAN. NAT reduces the number of IP addresses needed 
for a remote network by using only one address, instead of needing one address for the router, and 
one address for each PC on the remote network.

"Central"

LAN IP Address 199.2.2.1

Phone 13135551111

"Remote"
LAN IP Address 192.168.254.1
Phone 13135552222

ISDN

CSX1200

CSX100

199.2.2.2

192.168.254.2

192.168.254.3

WAN IP Address 199.2.2.3

DHCP Range
192.168.254.2
192.168.254.20

C A B L E T R O N   S Y S T E M S

POWER

SERVICE

TX

RX

10BASE - T

LAN                                                                                      B-CHANNELS                                                                          E1 ONLY 

B2 B4

B6 B8

B26 B28

B22 B24

B18 B20

B14 B16

B10 B12

B30 L1

B1 B3

B5 B7

B25 B27

B21 B23

B17 B19

B13 B15

B9 B11

B29 B31

E1

D

T1

D

Содержание CyberSWITCH CSX1000

Страница 1: ...WORKGROUP REMOTE ACCESS SWITCH QUICK START Release 7 2 Cabletron Systems 603 332 9400 phone 603 337 3075 fax support ctron com...

Страница 2: ...D TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Copyright 1998 by Cabletron Systems Inc All...

Страница 3: ...cs 1993 including one or more U S Patents No 4701745 5016009 5126739 and 5146221 and other pending patents Telenetworks Copyright 1991 92 93 by Telenetworks All rights reserved FCC NOTICE This device...

Страница 4: ...ontrol Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be requir...

Страница 5: ...e Configuration 17 Connectivity 19 Overview 19 Connecting a Workgroup Product to a Small Office Product via PPP 19 Bridge to Bridge Configuration 19 Configuration for Site Remote 20 IP Router to IP Ro...

Страница 6: ...QUICK START 6 CyberSWITCH AppleTalk Router to Bridge Configuration 32 Configuration for Site Central 32 Configuration for Site Remote 33 Index 34...

Страница 7: ...art is divided into two parts Basics This chapter gives detailed instructions on the initial installation steps that are required for all CyberSWITCH configurations Connectivity This chapter gives ins...

Страница 8: ...rminal or a workstation PC executing a terminal emulation program The second method is to Telnet to the system We describe each of these methods below CONNECTING AN ADMINISTRATION CONSOLE There are tw...

Страница 9: ...to your system To change the baud rate through CFGEDIT 1 Select Physical Resources from the main menu 2 Select Data Line from the physical resources menu 3 Follow the instructions to make changes to t...

Страница 10: ...l procedures are 1 Connect the system to the WAN ISDN line 2 From a remote device that supports UnNumbered IP connections dial in as a PPP CHAP device USER1 USER1 as secret The address on the CyberSWI...

Страница 11: ...following command at the system prompt manage While operating in Manage Mode only Dynamic Management commands are available All other system commands are ignored until you exit Manage Mode UPGRADING S...

Страница 12: ...ath directories LOCAL SOFTWARE UPGRADE To perform a local upgrade use any valid local administration console as defined in Connecting an Administration Console Update the SSB first if the Release Note...

Страница 13: ...er the name of the file that is to be downloaded using the complete pathname For example D CSX1204 US IPIPX UPGRADE OSW Note Your terminal program may display a character for the NAK control code typi...

Страница 14: ...le to issue restore command unless you have saved at least one set of changes If the upgrade still fails delete the nex bin and iop bin and again reclaim the space Your upgrade should now work IMPORTA...

Страница 15: ...D WRITE access to CONFIG files ADMIN has READ WRITE access to OTHER files Exit MANAGE MODE by typing exit RET 3 Using the TFTP client on the remote workstation TFTP the UPGRADE OSW file to the CyberSW...

Страница 16: ...guration changes are needed to provide this security 1 Either delete User1 and User2 or change their names and secrets Use Dynamic Management s manage mode to carry out either of these functions To en...

Страница 17: ...xt enter a password 2 Start up the configuration editor CFGEDIT at the system prompt type cfgedit Note If you are unsure of any configuration values use the defaults Use the displayed CFGEDIT menu to...

Страница 18: ...ng type chose common channel as the signaling type select the length of the line from the CSU to the CyberSWITCH as line build out 5 If you are using any accesses besides switched accesses such as ded...

Страница 19: ...nnecting a workgroup system to a small office system via PPP Separate instructions are included for bridging IP routing with an UnNumbered Interface IPX routing and AppleTalk routing configurations BR...

Страница 20: ...ill use determine how to make bridge dial out calls The two methods and how to configure them are listed below a Select Options from the main menu then the bridging menu and from the bridging menu sel...

Страница 21: ...is not on the same LAN as Remote Note that the bridge dial out configuration is slightly different for Remote than it was for Central IP ROUTER TO IP ROUTER CONFIGURATION CONFIGURATION FOR SITE CENTR...

Страница 22: ...outing to Central using PPP is as follows 1 Perform initial configuration steps 2 Under Options select Bridging then disable bridging Select IP Routing then a Enable IP Routing b Under IP Interfaces c...

Страница 23: ...hexadecimal IPX Network Number 11111111 3 Under Security select System Options and Information then under System Information a Set your System Name Central This matches up with Central device informat...

Страница 24: ...then under System Information a Set your System Name Remote This matches up with Remote device information configured on Central b Set your System Secret Remote_S This matches up with Remote device in...

Страница 25: ...ds if Calling Line Id security was enabled d Under AppleTalk Information you must Enter 0 0 for the AppleTalk address Enable AppleTalk Routing Enable making calls for AppleTalk data 3 Under Options se...

Страница 26: ...nder Security select Device Level Databases select On node Device Entries then add a device where the Device Name Central must match the system name on Central When you add the device you must then en...

Страница 27: ...and two router to bridge applications IPX and AppleTalk The documentation assumes that you are able to run QuickSET and have it find your CSX100 If you are unable to run QuickSET please refer to the...

Страница 28: ...otocol then select PPP b Under Authentication you must Change CHAP Secret so that it matches Remote s System secret Remote_S Optional Configure Calling Line Ids if Calling Line Id security was enabled...

Страница 29: ...erface and a hexadecimal IPX Network Number 0000BABE 3 Under Security select System Options and Information then under System Information a Set your System Name Central This matches up with Central de...

Страница 30: ...WITCH Name Remote and System Password Remote_S c Select your switch type d Enter the directory number for the CSX100 13135552222 Click Next e Enable IPX Routing by clicking in the box f Set the Extern...

Страница 31: ...r Security select Device Level Databases select On node Device Entries then add a device where the Device Name Remote must match the system name on Remote When you add the device you must then enter t...

Страница 32: ...ONFIGURATION CONFIGURATION FOR SITE CENTRAL The configuration on Central to allow AppleTalk Routing to Remote is as follows 1 Perform initial configuration steps 2 Under Options select AppleTalk Routi...

Страница 33: ...Remote When you add the device you must then enter the following information a Under ISDN Information select ISDN Line Protocol then select PPP b Under Authentication you must Change CHAP Secret so th...

Страница 34: ...DOC notice 4 dynamic management access to 11 defined 11 features described 11 E ESF 18 expansion resources adding 17 F factory defaults 17 FCC notice 3 framing type ESF 18 L line build out 18 line co...

Отзывы: