3-5
9C214-2 Power Supply Operation
The Power Supply Level Indicator LED indicates, by segment number, the
percentage of the power supply’s capacity being used. The possible states and
descriptions of the Power Supply Level Indicator LED are listed in Table 3-3.
Load Sharing
Each 9C214-2 Power Supply uses a current sharing design. This design allows
multiple power supplies to equally (within ± 5%) share the output load. For
example, if two power supplies are used, each power supply provides 50% ± 5%
of the output load. This feature increases the life of each power supply.
Table 3-3. Power Supply Level Indicator LED
Segment
Number(s)
LED
Color
State
Description
1 - 5
Green
0–49% of power load being
used.
No action necessary.
6 - 9
Green
50-89% of power load being
used. No parallel power supply
operational.
No action necessary.
6 - 9
Green/
Yellow
50-89% of power load being
used. Parallel supply(ies)
installed; however, yellow
indicates loss of redundancy.
Add an additional
power supply if
redundancy is
desired.
10
Yellow
Greater than 90% of power
supply being used.
Add an additional
power supply for
redundancy.
11
Red
Overload condition exists.
Add an additional
power supply or
reduce number of
modules in the
chassis.
Содержание 9C214-2
Страница 1: ...SmartSwitch 9000 9C214 2 DC Power Supply Installation Guide 9031305 05 ...
Страница 2: ......
Страница 6: ...Notice iv ...
Страница 8: ...Contents vi ...
Страница 14: ...Introduction 1 6 ...
Страница 26: ...9C214 2 Power Supply Operation 3 6 ...
Страница 30: ...Specifications 4 4 ...