FE-100F3
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
B-3
B.3
FE-100F3
The FE-100F3 shown in
Figure B-3
uses an SC style connector that
supports single mode fiber optic cabling. Specifications for the FE-100F3
are listed in
Table B-2
below.
Figure B-3
FE-100F3
Table B-2
Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
8/125 µm fiber
>10.0 dB
<10.0 dB
12/125 µm fiber
>10.0 dB
<10.0 dB
NOTE
The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
FE-100F3
26
25
2076_8
Содержание 6E122-26
Страница 2: ...9032076 05...
Страница 12: ...Contents x 6E122 26 6E132 25 6E123 26 and 6E133 25 User s Guide...
Страница 24: ...Chapter 1 Introduction 1 12 6E122 26 6E132 25 6E123 26 and 6E133 25 User s Guide...
Страница 48: ...Chapter 4 Troubleshooting 4 8 6E122 26 6E132 25 6E123 26 and 6E133 25 User s Guide...
Страница 164: ...Chapter 5 Local Management 5 116 6E122 26 6E132 25 6E123 26 and 6E133 25 User s Guide...
Страница 168: ...Appendix A Specifications A 4 6E122 26 6E132 25 6E123 26 and 6E133 25 User s Guide...
Страница 172: ...Appendix B FE 100TX FE 100FX and FE 100F3 Specifications B 4 6E128 26 6E138 25 6E129 26 and 6E139 25 User s Guide...
Страница 180: ...Appendix C Mode Switch Bank Settings and Optional Installations C 8 6E122 26 6E132 25 6E123 26 and 6E133 25 User s Guide...