Interface Device View

Interface Icons

Device Views

Cisco Catalyst 5000/5500 Hub

2-4

Management Module Guide

Interface Label 

This label displays the interface (port) number.

Administrative Status Label 

This label displays the status of this interface. Double-click this label to open 
the Interface Status view which allows you to view the operational state of 
that interface, and select the administrative status (enable or disable the 
port). 

Table 2-1

 lists the possible states and their descriptions. 

Interface Type Label

This label displays the interface type. Some of the possible interface types are 
Ethernet, FDDI, T1, PPP, and Reg1822. 

MAC Address Label

This label displays the MAC address of this device. Double-click this label to 
open the Interface Address Translation table. 

Interface Address Translation Table

This table cross-references device IP addresses to device MAC (Physical) 
addresses for selected nodes between networks. Double-click any column 
entry to open an address-speciÞc Address Translation Table Information view. 
The Interface Address Translation Table provides the following information:

Interface Index

A list of interfaces held by the device. 

Physical Address

Displays the physical (MAC) address of the interface.

Table 2-1.

Administrative Status Label Descriptions

Color

Status

Description

Green

ON 

Port is operational.

Blue

OFF

Port is off.

Yellow

TESTING

Port is in the test mode.

Содержание 5000, 5500

Страница 1: ... Cisco Catalyst 5000 5500 Hub Management Module Guide ...

Страница 2: ...ti virus system is 100 reliable we strongly caution you to write protect and then verify that the Licensed Software prior to installing it is virus free with an anti virus system in which you have conÞdence Cabletron Systems makes no representations or warranties to the effect that the Licensed Software is virus free Copyright April 1998 by Cabletron Systems Inc All rights reserved Printed in the ...

Страница 3: ... which it was acquired is inoperative 3 Reproduced for safekeeping archives or backup purposes 4 Modified adapted or combined with other computer software provided that the modified combined or adapted portions of the derivative software incorporating restricted computer software are made subject to the same restricted rights 5 Disclosed to and reproduced for use by support service contractors in ...

Страница 4: ...What Is in This Chapter 2 1 Interface Device View 2 1 Interface Icons 2 3 Interface Label 2 4 Administrative Status Label 2 4 Interface Type Label 2 4 MAC Address Label 2 4 Interface Address Translation Table 2 4 Network Information Label 2 5 Gauge Label 2 5 Interface Options Panel 2 6 Gauge Control Panel 2 6 Chassis Device View 2 10 Module Icons 2 11 Module Number Label 2 12 Module Status Label 2...

Страница 5: ... Device Events and Alarms 4 1 Chapter 5 Application View What Is in This Chapter 5 1 Common Applications 5 1 Device Application View 5 2 Catalyst Stack Application 5 5 Community Strings 5 8 FDDI Ring Table 5 9 Catalyst Filter Tables 5 10 MAC Table 5 10 Vendor Table 5 11 Protocol Table 5 11 Test Table 5 12 Port Table 5 12 Monitor Information View 5 13 Catalyst TFTP Information View 5 14 Catalyst Tr...

Страница 6: ...9032208 E4 v Index ...

Страница 7: ...Cisco Catalyst 5000 5500 Hub vi Management Module Guide ...

Страница 8: ... 2 Device Views Figure 2 1 Interface Device View 2 2 Figure 2 2 Interface Icon 2 3 Figure 2 3 Gauge Control Panel 2 7 Figure 2 4 Cisco Catalyst 5000 Chassis Device View 2 11 Figure 2 5 Module Icon 2 12 Figure 2 6 Module IdentiÞcation Labels and Click Zones 2 12 Figure 2 7 Port Label 2 15 Chapter 5 Application View Figure 5 1 Device Application View Icon Mode 5 3 Figure 5 2 Device Application View ...

Страница 9: ...Cisco Catalyst 5000 5500 Hub viii Management Module Guide ...

Страница 10: ...Types 3 5 Table 3 2 Possible System Types for the Cisco Catalyst 5000 5500 3 6 Table 3 3 Module Status Descriptions 3 9 Table 3 4 Possible Port Types 3 10 Table 3 5 Additional Status Definitions 3 11 Chapter 4 Event and Alarm Messages Table 4 1 Catalyst Switch Events and Alarms 4 1 Chapter 5 Application View Table 5 1 Catalyst Stack Application Specific Icon Subviews Menu Selections 5 5 Table 5 2 ...

Страница 11: ...Cisco Catalyst 5000 5500 Hub x Management Module Guide ...

Страница 12: ... 1 Introduction Describes the device the management module and model types This chapter also provides information on accessing device speciÞc views Chapter 2 Device Views Describes the Device views representing the device Chapter 3 ConÞguration Views Describes the ConÞguration views for the device and the network management information provided by the views Chapter 4 Event and Alarm Messages Lists...

Страница 13: ...tion Referenced chapter titles and section headings appear in italics Referenced documents appear in bold italics References in blue are hypertext links for online documents Cisco Catalyst 5000 Hubs are referred to as Òdevices Ó Related SPECTRUM Documentation When using this guide you should have a clear understanding of SPECTRUM functionality and navigation techniques as described in the Administ...

Страница 14: ... Leben Local Area Networks Architectures and Implementations 2d ed Englewood Cliffs NJ Prentice Hall 1994 Rose Marshall T The Simple Book An Introduction to Management of TCP IP based Internets Englewood Cliffs NJ Prentice Hall 1991 Stallings William Data and Computer Communications 4th ed New York Macmillan Publishing Company 1994 Tanenbaum Andrew S Computer Networks 3d ed Englewood Cliffs NJ Pre...

Страница 15: ...Other Related Documentation Preface Cisco Catalyst 5000 5500 Hub xiv Management Module Guide ...

Страница 16: ...es Copper Distributed Data Interface multilevel transmission CDDI MLT 3 and single multimode Fiber Distributed Data Interface FDDI connectivity The Cisco Catalyst provides bridging and routing capabilities in a Virtual Local Area Networking VLAN environment Its architecture supports switched connections to the following media 10BaseT and 100BaseT Fast Ethernet 4 16 Mbps Token Ring Copper Distribut...

Страница 17: ...ns that appear in various views in SpectroGRAPH Icons representing devices provide at a glance color coded status information Both device icons and application icons also provide mouse click access to other views that contain detailed conÞguration and performance information SPECTRUM management modules are software packages that provide templates for creating software models of particular devices ...

Страница 18: ...ormation on conÞguring your mouse Figure 1 1 Using Double Click Zones to Access SPECTRUM Views Model Name HubCat5000 Accesses the Device Topology view refer to the SPECTRUM Views guide Accesses the Device view see Chapter 2 Device Views Accesses the Device Topology view refer to the SPECTRUM Views guide Accesses the ConÞguration view see Chapter 3 ConÞguration Views Accesses the Performance view r...

Страница 19: ...ierarchy File View Help Close ctrl c Navigate Alarms Performance Notes Utilities Zoom Application Chassis Information Device DevTop Acknowledge Flash Green Enabled Configuration Model Information Primary Application Primary Landscape 0x00400000 VNM Host LAN of type Landscape Interface Chassis Close Ctrl C Navigate Alarms Performance Notes Utilities Module Notes Module Configuration Module SpeciÞc ...

Страница 20: ...iews guide DevTop view refer to the SPECTRUM Views reference Device views see Chapter 2 Device Views Interface Device view Chassis Device view Device ConÞguration view System ConÞguration view Bridging Application refer to the Bridging Applications Reference MIB II Application refer to the MIB II Applications Reference ConÞguration view see Chapter 3 ConÞguration Views Application view see Chapter...

Страница 21: ...SPECTRUM Views Roadmap Introduction Cisco Catalyst 5000 5500 Hub 1 6 Management Module Guide ...

Страница 22: ...section describes the Interface Options panel and the Interface icons displayed in the Interface Device view This view provides dynamic conÞguration and performance information for each interface on this device If the conÞguration changes SPECTRUM modiÞes the Device view after the next polling cycle to reßect the new conÞguration This view also provides a Device icon which allows you to monitor th...

Страница 23: ...cation Interface Options Panel Device Icon Interface Icons 1 ON Ethernet 0 01D 17 2F 3C 0 5 OFF ETHERNET 0 01D 17 2F 3C 0 9 OFF ETHERNET 0 01D 17 2F 3C 0 13 OFF ETHERNET 0 01D 17 2F 3C 0 2 ON SLIP 0 01D 17 2F 3C 0 6 OFF ETHERNET 0 01D 17 2F 3C 0 10 OFF ETHERNET 0 01D 17 2F 3C 0 14 OFF ETHERNET 0 01D 17 2F 3C 0 3 OFF ETHERNET 0 01D 17 2F 3C 0 7 OFF ETHERNET 0 01D 17 2F 3C 0 11 OFF ETHERNET 0 01D 17...

Страница 24: ...dress Translation Table e Network Information Label Network Information Panel f Gauge Label Performance View NOTES The callouts a through f displayed in the illustration below identify the label and the view to which it provides double click access Example Administrative Status Label IF Status view displays the administrative status and provides double click access to the IF Status view The menu d...

Страница 25: ...e Ethernet FDDI T1 PPP and Reg1822 MAC Address Label This label displays the MAC address of this device Double click this label to open the Interface Address Translation table Interface Address Translation Table This table cross references device IP addresses to device MAC Physical addresses for selected nodes between networks Double click any column entry to open an address speciÞc Address Transl...

Страница 26: ... the Interface Options Panel described later in this chapter or do the following 1 Double click the label to open the Network Information Panel 2 Click the network information entry you wish to display 3 Click OK Gauge Label This label displays the performance statistic determined by the Gauge Control Panel for this interface See the Gauge Control Panel later in this chapter for more information D...

Страница 27: ...earch for Not all column headings will activate the Find button Network Information This menu button allows you to select the type of information displayed in the Network Information label of the highlighted icon Possible selections are ADDRESS NAME or MASK Interface Description This Þeld provides a description of the highlighted interface If no interface is highlighted this Þeld is empty Gauge Co...

Страница 28: ...n displays the percentage of the selected interface compared to the rest of the interfaces The color displayed on the Gauge Label depends upon the particular mode and statistical attribute selected Table 2 2 and Table 2 3 provide a list of attributes and their corresponding colors for the Totals mode and Rates mode respectively Gauge Buttons Gauge Mode Selected Attribute Rates Load Totals Load In ...

Страница 29: ... Gauge Mode Attributes and Corresponding Color Selected Attribute Color In Errors Orange Out Errors Orange In Packets Blue Out Packets Blue Unknown Protocols Yellow In No Resource Tan Out No Resource Tan In Octets Green Out Octets Green Table 2 3 Rates Gauge Mode Attributes and Corresponding Color Selected Attribute Color Load Green Load In Green Load Out Green Packet Rate Blue Packet In Rate Blue...

Страница 30: ...trol Panel provides the following buttons Applies the current settings to the Gauge label temporarily but does not save the settings Returns the settings to the previously saved values Saves the current settings while SpectroGRAPH is running Settings return to default when you restart SpectroGRAPH Closes the Gauge Control Panel Returns the settings to the SPECTRUM default Apply Reset Keep Settings...

Страница 31: ...out the device and the modules it manages The Chassis Device view is divided into two sections The top section provides information about the Cisco Catalyst 5000 5500 Hub as a whole The bottom section provides information about the individual modules installed in the chassis Figure 2 4 shows an example of the Chassis Device view for this device ...

Страница 32: ...e 2 5 shows an example of a Module icon File View Help Primary Landscape 0x00400000 VNM Host Machine Model Name Contact Description Location Net Addr Prime App Sys UpTime Manufacturer DeviceType Serial Number 1 On wsx5009 OK 1 Other 9 Other 2 10 Other Other 3 11 Other Other 4 12 Other Other 5 13 Other Other 6 14 Other Other 7 15 Other Other 8 16 Other 1 On wsx5010 OK 1 Other 2 Other 3 Other 4 Othe...

Страница 33: ...notes or 1 Within the Chassis Device view Figure 2 4 highlight the Module icon 1 On wsx5010 Port Icons OK 1 Other 9 Other 2 10 Other Other 3 11 Other Other 4 12 Other Other 5 13 Other Other 6 14 Other Other 7 15 Other Other 8 16 Other Module IdentiÞcation Label NOTES The callouts displayed in the illustration below identify the label and the view to which it provides double click access Example Mo...

Страница 34: ...ion information It is divided into the two sections described below Module This area of the Module Table view provides the following information Index Displays the slot number in which this module is inserted in the chassis Valid entries are 1 to the maximum number of slots in this chassis Type Displays the type of module Serial Nbr Displays the serial number for this module Name Displays the user...

Страница 35: ...l Þelds appear in this view Sub Type Shows the type of daughterboard attached to this module Possible types are Other and Empty Test Results Displays the test results from the last completed self test of this module A zero indicates that the module passed all tests Bits set in the result indicate error conditions Refer to the hardware documentation for deÞnitions of the error conditions Versions T...

Страница 36: ...for recording port speciÞc notes or 1 Within the Chassis Device view Figure 2 4 highlight the Port icon 2 From the Icon Subviews menu select Port Notes Port Status Label This label displays the status of the port This label also displays the device port types Some of the possible types are Other CDDI FDDI etc Double click the Port Status label of the Port Icon to access the Port Table view or do t...

Страница 37: ...number Status Displays the current status of this module Table 2 5 shows the possible states Additional Status Displays an integer representing additional information on the status of this port Table 2 6 provides deÞnitions of the additional status values Table 2 5 Port Status DeÞnitions Operational Status Administrative Status Text Display Color ON ON ON Green OFF OFF OFF Blue OFF ON OFF Yellow T...

Страница 38: ...s detected on the port in the last polling period No packets were transmitted and no packets were received 5 At least one packet was transmitted and at least one collision was detected in the last polling period No packets were received 6 At least one packet was received and at least one collision was detected in the last polling period No packets were transmitted 7 At least one packet was transmi...

Страница 39: ...Chassis Device View Port Icons Device Views Cisco Catalyst 5000 5500 Hub 2 18 Management Module Guide ...

Страница 40: ...e Chapter 1 Introduction for information on Accessing SPECTRUM Views Device ConÞguration View This view provides two areas of information on the conÞguration and operating status of this device They are described in the following sections Device ConÞguration Information This section of the Device ConÞguration view displays the following device speciÞc information Device Name Displays the user deÞn...

Страница 41: ...the devices in the chassis Interface ConÞguration Table This table within the Device ConÞguration view provides the following conÞguration information for the device and each port Index Displays the interface or port number Description Provides a description of the interface or port Type Displays the type of hardware interface or port Some of the possible types are Ethernet FDDI T1 PPP and Reg1822...

Страница 42: ... select IF ConÞguration This view provides the following information Operation Status Displays the current operating status of the interface or port Possible values are On Off and Testing Admin Status Displays the current administrative state of the interface or port Possible values are On Off and Testing Last Change Displays the value of sysUpTime at the time the interface entered its current ope...

Страница 43: ...information Mgmt Type Displays the type of network management running on the device Possible management types include ÒOtherÓ none of the following ÒsnmpV1Ó ÒsmuxÓ SNMP MUX sub agent and ÒsnmpV2V1Ó bi lingual SNMP Net Mask Displays the subnet mask for the device Broadcast Displays the broadcast address of the device Baud Rate Displays the baud rate of the deviceÕs RS 232 port in bits per second Cl...

Страница 44: ... in the device The default is Other TrafÞc Displays the value of the trafÞc meter shown as a percentage of bandwidth utilization on the network for the previous polling interval Enable Redirects Allows you to select whether the device is able to send or receive ICMP redirect messages Enable Modem Allows you to select whether this deviceÕs RS 232 port modem control lines are enabled or disabled Ena...

Страница 45: ...evice To access this view click the Chassis button in the Catalyst Stack System ConÞguration view The Chassis Information view provides the following information Chassis This section of the Chassis Information view provides the following hardware information about the device Model Displays the manufacturerÕs model number for the chassis System Type Displays the type of chassis system Table 3 2 lis...

Страница 46: ... 10 100BaseTX wsx5020 48 Port 4 Segment 10BaseT wsx5006 Supervisor Module 2 100BaseFX Multi Mode wsx5005 Supervisor Module 2 100BaseFX Single Mode wsx5509 Supervisor Module II 2 100BaseTX wsx5506 Supervisor Module II 2 100BaseFX Multi Mode wsx5505 Supervisor Module II 2 100BaseFX Single Mode wsx5156 1 Dual Phy UTP OC 3 ATM wsx5157 1 Dual Phy Single Mode OC 3 ATM wsx5158 1 Dual Phy Multi Mode OC 3 ...

Страница 47: ...y installed as the Þrst power supply A zero indicates that the power supply passed all tests 2 Type Displays the type of power supply installed as the second power supply for the device Possible power supply types are Other None 50w 200w 600w 80w and 130w 2 Status Displays the current status of the power supply installed as the second power supply Possible statuses are Other OK MinorFault and Majo...

Страница 48: ...Stack Modules table click the Modules button in the Catalyst Stack System ConÞguration view Double click any table entry to access the Catalyst Stack Module Table view for that entry The Catalyst Stack Modules table provides the following information for each module Index Displays the slot number in which this module is inserted in the chassis Valid entries are 1 to the maximum number of slots in ...

Страница 49: ...ble click the Ports button in the Catalyst Stack System ConÞguration view Double click any table entry to access the entry speciÞc Port Table view described in Chapter 2 Device Views The Catalyst Stack Ports table provides the following information Module Displays the unique integer identiÞer of the module where this port is located This number is the same as the slot number in which the module is...

Страница 50: ...eriod 1 At least one packet was transmitted by the port in the last polling period No packets were received and no collisions were detected 2 At least one packet was received by the port in the last polling period No packets were transmitted and no collisions were detected 3 At least one packet was transmitted and at least one packet was received in the last polling period No collisions were detec...

Страница 51: ...ration Views Cisco Catalyst 5000 5500 Hub 3 12 Management Module Guide Sort On This button allows you to select one of the table column headings as a sort key Order This button allows you to sort the table in ascending or descending order within the selected Sort On category ...

Страница 52: ...lists the SPECTRUM database directory paths in bold and the messages displayed for the Event Log and Alarm Manager when applicable Table 4 1 Catalyst Switch Events and Alarms Message in the Event Log Alarm View Probable Cause Message CsEvFormat Event00010306 d Ò w d m Y TÓ A n t device named m has been cold started event e No probable cause message CsEvFormat Event00010307 d Ò w d m Y TÓ A n t dev...

Страница 53: ... named m has detected an EGP Neighbor Loss EGP Neighbor IP address is 0 1 event e CsPCause Prob0001030b Lost contact with EGP neighbor CsEvFormat Event00010401 d Ò w d m Y TÓ Device m of type t is created with an IP address already used by another model event e CsPCause Prob00010401 DUPLICATE IP ADDRESS The model has the same IP address as that of some other model CsEvFormat Event00010402 d Ò w d ...

Страница 54: ... Ok state event e No probable cause message CsEvFormat Event011c0004 d w d m Y T Module I 1 has transitioned out of the Ok state event e No probable cause message CsEvFormat Event011c0005 d w d m Y T The chassis temp alarm is T CatChasAlrm 1 the chassis Minor alarm is T CatChasAlrm 2 and the chassis Major alarm is T CatChasAlrm 3 event e No probable cause message Table 4 1 Catalyst Switch Events a...

Страница 55: ...sending to all conÞgured recipients managementDomainConÞgRevNumb er I 1 Event e No probable cause message CsEvFormat Event011c0007 d Ò w d m Y TÓ Device m of Type t reported A conÞguration digest error notiÞcation which signiÞes that a device has incremented its vtpConÞgDigestErrors counter Generation of this notiÞcation is suppressed if the vtp NotiÞcationsEnabled has the value ÔfalseÕ The device...

Страница 56: ... m Y TÓ Device m of Type t reported A VTP MTU tooBig notiÞcation This trap is generated when a VLANÕs MTU size is larger than can be supported either by one or more of its trunk ports the included vtpVlanState has the value ÔmtuTooBigForTrunkÕ and the included vlanTrunkPortManagementDomain is for the Þrst or only trunk port or by the device itself vtpVlanState has the value ÔmtuTooBigForDeviceÕ an...

Страница 57: ...Device Events and Alarms Event and Alarm Messages Cisco Catalyst 5000 5500 Hub 4 6 Management Module Guide ...

Страница 58: ...p Ethernet Application EthernetApp The Application view allows you to access increasingly detailed views of network information for the applications supported by this device Common Applications This device supports the following common applications described in the MIB II Applications Bridging Applications and Miscellaneous Applications references MIB II SNMP2_Agent IP IP2_App System System2_App I...

Страница 59: ...App Device Application View This view shows the common and device speciÞc applications supported by this device and provides access to application speciÞc information See Chapter 1 Introduction for information on Accessing SPECTRUM Views Figure 5 1 provides an example of an Application view in the icon mode Figure 5 2 provides an example of an Application view in the list mode To change the displa...

Страница 60: ...tic Static_App Gen Bridge App Gen_Bridge_App Spanning Tree Span_Tree_App Static Static_App MIB II SNMP2_Agent SNMP2_Agent ICMP ICMP_App ICMP_App System System2_App System2_App TCP TCP2_App TCP2_App CatalystStack CATStackApp CATStackApp EthernetApp 1 EthernetIfApp EthernetApp 2 EthernetIfApp EthernetApp 4 EthernetIfApp EthernetApp 3 EthernetIfApp EthernetApp EthernetApp EthernetIfApp SMT 5 GemFDDIS...

Страница 61: ...File View Help Primary Landscape 0x00400000 HubCat 5000 of type HubCat 5000 Model Name Contact Description Location Net Addr Prime App Sys UpTime Manufacturer DeviceType Serial Number Catalyst GenBridgeApp Span_Tree_App Static_App Transparnt_App CATStackApp Ethernet_App FDDI_App MIB II ICMP_App IP2_App System2_App UDP2_App TCP2_App CiscoCDPApp ...

Страница 62: ... Menu Selections Menu Selection Description ConÞguration Opens the Catalyst Stack ConÞguration view Page 3 4 Bridge Router Opens the BRouter Information view Page 5 5 Community Strings Opens the Community Strings View Page 5 8 FDDI Ring Opens the FDDI Ring Table Page 5 9 Filter Opens the Catalyst Filter Tables Page 5 10 Monitor Opens the Monitor Information View Page 5 13 TFTP Opens the Catalyst T...

Страница 63: ... you to enable or disable IP Fragmentation on the Catalyst Switch Allows you to enable or disable the Spanning Tree protocol on the Catalyst Switch Allows you to enable or disable the Catalyst SwitchÕs ability to give special handling to giant packets Allows you to select whether the Catalyst Switch is able to send ICMP unreachable messages Enable Rip Enable IP Frag Enable Spantree Enable Giant Ch...

Страница 64: ...e default translation for IPX packets when bridging from Ethernet 802 3 Raw to FDDI Possible options are SNAP and ISO8022 Ethernet Receive Max Displays the maximum number of Ethernet receive buffers processed at one time per port Ethernet Transmit Max Displays the maximum number of Ethernet transmit buffers processed at one time per port FDDI Receive Max Displays the maximum number of FDDI receive...

Страница 65: ...icon mode or model type name list mode 2 From the Icon Subviews menu select Community Strings Table 5 2 BRouter Ports Table Field DeÞnitions Column Heading DeÞnition Module The unique integer identiÞer of the module where this port is located This number is the same as the slot number in which the module is installed Port The unique integer identiÞer of this port within its module This value is de...

Страница 66: ...r model type name list mode 2 From the Icon Subviews menu select FDDI Ring The FDDI Ring Table and its corresponding entry speciÞc views provide the following information SMT Index Displays the SMT index number that identiÞes this ring Address Displays the MAC address of this node in the ring Next Address Displays the MAC address of the next node in the ring Information can be sorted listed in asc...

Страница 67: ... following information Module Displays the unique integer identiÞer of the module where this port is located This number is the same as the slot number in which the module is installed Port Displays the unique integer identiÞer of this port within its module This value is determined by the location of the port on the module Address Displays the MAC address to which the source and destination MAC a...

Страница 68: ...action this Þlter will cause Selecting ÒInvalidÓ removes this Þlter from the table Selecting ÒDenyÓ causes packets whose source or destination vendor ID matches the vendor ID speciÞed in the ID Þeld to be dropped Selecting ÒPermitÓ causes all packets whose vendor ID does not match the ID speciÞed in the ID Þeld to be dropped Protocol Table The Protocol Table contains a list of protocol Þlter entri...

Страница 69: ... located This number is the same as the slot number in which the module is installed Port Displays the unique integer identiÞer of this port within its module This value is determined by the location of the port on the module Index Displays an index value that uniquely identiÞes a test for a particular module and port Test Table only Type Validates or shows a new module port or test index when one...

Страница 70: ... icon 2 From the Icon Subviews menu select Monitor This view provides the following information Source Module Displays the unique integer identiÞer of the module where the monitoring source port is located A value of zero indicates that the source port is really a source Virtual LAN number Source Port Displays the unique integer identiÞer of the monitoring source port within its module or the moni...

Страница 71: ...he operator deÞned name of the Þle for this Þle transfer Module Displays the operator deÞned number of the module to or from which code or conÞguration information is being transferred Action This button allows you to select the type of transfer to be carried out and to initiate the transfer Possible actions are listed in Table 5 4 Table 5 4 TFTP Transfer Action Types Action DeÞnition Other Defaul...

Страница 72: ...atus of this entry Setting this value to ÒInvalidÓ removes the corresponding entry from the Trap Receiver Table To add a new entry to the Trap Receiver Table set this value to ÒValidÓ for an IP address that is not already in the table Addr Displays the IP address of the Network Management Station receiving the traps Community Displays the community string used for trap messages sent to this trap r...

Страница 73: ...t uniquely identiÞes this port within this module Port Displays the port number within the identiÞed module Vlan Displays the Virtual LAN to which this port is attached Switch Level Displays the switch priority level the port uses to access the switching media If the port is functioning correctly the ÒNormalÓ value appears Catalyst VLan Manager This view provides a graphical display of the deviceÕ...

Страница 74: ... on the VLAN number to display or assign ports The VLAN number icon and the ports assigned to that VLAN will be highlighted Figure 5 3 VLAN Panel Adding a VLAN Within the VLAN panel enter the number of the VLAN you would like to add Click the ÒAddÓ button A button representing the new VLAN will appear in the VLAN panel 1 2 3 44 ports 20 ports 24 ports VLAN Number Icon ...

Страница 75: ... Highlight that VLANÕs number icon Click the ÒRemoveÓ button The VLAN will be removed from the VLAN panel Discovery Application This section describes the Discovery Application supported by the cisco Catalyst Hub The model type name for this application is CiscoCDPApp Table 5 5 describes each of the application speciÞc Icon Subviews menu selections available for the Discovery Application Remove Ad...

Страница 76: ... was reported Platform Displays the devices hardware platform Capabilities Displays the devices functional capabilities Interface Discovery Status Table This table contains the status of Cisco Discovery Protocol on the device s interfaces It provides the following information Discovery Displays information about the type of devices in the network conÞguration information about the links connecting...

Страница 77: ... This application provides access to the application speciÞc Detail view To access the Detail view select Detail from the Icon Subview menu This view provides access to three pie charts with performance statistics For more information about the frame or transmit error performance statistics refer to How to Manage Your Network with SPECTRUM ...

Страница 78: ...ode 100BaseFX 3 7 A Accessing SPECTRUM Views 1 3 Action Button 2 14 Additional Status 2 16 3 11 Additional Status Value 2 16 Addr 5 15 Address 5 9 5 10 5 19 Network 2 6 address MAC 2 4 3 2 3 3 Admin Status 3 3 Administrative Status 2 16 3 3 Administrative Status Label 2 4 Alarm Messages 4 1 Alarms 3 9 Application View 5 1 Tables 5 5 Application Views Catalyst Stack 5 5 Apply button 2 9 ARP Aging T...

Страница 79: ... 2 Destination Module 5 13 Port 5 13 Device Name 3 1 Device Application View 5 2 Device ConÞguration Information 3 1 Device ConÞguration View 3 1 Device ID 5 19 Device Port 5 19 Device View 2 1 Banner 2 12 Chassis 2 10 Interface 2 1 2 2 Direction Button 5 13 Discovery 5 19 Discovery Cache Table View 5 19 Documentation xii documentation conventions xii organization xi DownLoadConÞg 5 14 DownLoadFw ...

Страница 80: ...3 Index 2 13 2 16 3 2 3 9 3 10 5 12 Insert Mode Button 3 5 Interface Description 2 6 Device View 2 1 Icon Logical 2 6 Panel 2 12 Options Panel 2 6 interface icon Device View 2 3 2 11 type 2 4 Interface ConÞguration Table 3 2 Interface Device View 2 1 2 2 Interface Discovery Status Table 5 19 Interface Icon Device View administrative status label 2 4 gauge label 2 5 illustration 2 3 interface numbe...

Страница 81: ...orts 2 14 Number Interfaces 3 2 Slots 3 8 O Offset 5 12 Operation Status 3 2 3 3 Operational Status 2 16 Order 3 10 3 12 Other 3 5 5 14 Other Related Documentation xiii P Packet Size 3 3 3 4 Permit 5 10 Physical Address 2 4 3 2 3 3 Platform 5 19 Port 5 8 5 10 5 11 5 12 5 13 5 19 Table Catalyst Stack 5 12 Port Icon 2 15 Port Table View 2 16 Ports 3 10 Button 3 6 Table 3 9 Power Supplies 3 8 Protoco...

Страница 82: ...able 5 12 TFTP Information View 5 14 Throttle 5 13 Trademarks i TrafÞc 3 5 Transparent 5 2 Transparent_Ap 5 2 trap messages 5 15 Trap Receiver Table 5 15 Type 2 13 2 16 3 2 3 9 3 10 5 10 5 11 5 12 5 15 5 19 U UDP Application 5 1 UDP2_App 5 1 unique integer identiÞer 5 10 UpLoadConÞg 5 14 UpLoadFw 5 14 UpLoadSw 5 14 V Value 5 11 5 12 vendor ID Þlter 5 11 Vendor Table 5 11 Versions 2 14 Virtual LAN ...

Страница 83: ...Index Cisco Catalyst 5000 5500 Hub 6 Management Module Guide ...

Отзывы: