Cablematic BLE-485C Скачать руководство пользователя страница 4

Device Information

Firmware Revision String

NOTIFY

RxData

BLE_CONF

MacID

DeviceName

DeviceName

PinID_Setting

Serial BLE Service

SetCharacteristicNotification(Char)

SetCharacteristicNotification

 (Char)

SetCharacteristicNotification(Char)

writeCharacteristic(Char)

writeCharacteristic(Char)

writeCharacteristic(Char)

writeCharacteristic(Char)

writeCharacteristic(Char)

writeCharacteristic(Char)

Mobile APP

SERIAL

BLE RS-485 Serial Adapter

User Manual V1.3

5.2 Programming Interfaces:

GATT

UUID

UUID_Device Information

0000180A-0000-1000-8000-00805F9B34FB

UUID_Firmware Revision String

00002A26-0000-1000-8000-00805F9B34FB

UUID_NOTIFY (~20 bytes)

00031234-0000-1000-8000-00805F9B0130

UUID_RxData (~20 bytes)

00031234-0000-1000-8000-00805F9B0131

UUID_MacID (6 bytes)

00031234-0000-1000-8000-00805F9B0133

UUID_DeviceName (15 bytes)

00031234-0000-1000-8000-00805F9B0134

UUID_Reboot (1 bytes)

00031234-0000-1000-8000-00805F9B0135

UUID_PinID_Setting (6 bytes)

00031234-0000-1000-8000-00805F9B0136

UUID_BLE_CONF (7 bytes)

00031234-0000-1000-8000-00805F9B0132

Byte0

Byte1

Byte2

Byte3

Data bit

RS-485 CRC

Stop Bit

Parity Bit

7,8

0x01:on

0x00:off

2:1

3:1.5

0x02 : No Parity

0x01 : Odd Parity

4

Содержание BLE-485C

Страница 1: ...ge Weight 105 g Package Contents BLE 422 485 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data...

Страница 2: ...Remark 1 000000000 by default in red bold character 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 3 Power sup...

Страница 3: ...rvice and AT command will support all the functions please check the page 4 section 5 and page 5 section 6 4 3 Range max 50 m in open space 4 4 TX Power Max 3 dBm 4 5 RX Sensitivity 89 dBm typical 4 6...

Страница 4: ...UUID UUID_Device Information 0000180A 0000 1000 8000 00805F9B34FB UUID_Firmware Revision String 00002A26 0000 1000 8000 00805F9B34FB UUID_NOTIFY 20 bytes 00031234 0000 1000 8000 00805F9B0130 UUID_RxD...

Страница 5: ...connection is ok Response ERROR when the connection is not ok AT Test the RS 232 status when first connect the adapter with the controller Default N The command will disable the auto link function In...

Страница 6: ...ice name for the adaptor You can specify a friendly name using 0 to 9 A to Z a to z space and which are all valid characters Note that first space or last space or isn t permitted The default name is...

Страница 7: ...re the current setting VERSION This command is used to inquiry the firmware version Inquire the version codes 7 RS 485 Wire connection 8 APP Download Android iOS APP Sample code Please contact the sup...

Страница 8: ...n and select one Connect and configure Data transmission test 8 Disconnect TX area RX area Data mode Clear data and log Device list Select one Enable Central Setup Reset Default Serial Port setting Ba...

Отзывы: