Cablematic BLE-485C Скачать руководство пользователя страница 2

BLE RS-485 Serial Adapter

User Manual V1.3

Link LED flash

No Link

Data & Link LED solid on

OTA Mode

2. Rear view:

Setup

Modbus

Stop

Bit

Parity

Role

Baud Rate

DIP9

DIP8

DIP7

DIP6  DIP5

DIP4

DIP3 DIP2 DIP1

0: Switch

1: 

Command

0: Normal

1: Add CRC

RS485 only

0: 1

1: 2

00: None

01: Odd

10: Odd

11: Even

0:Slave

110:2400

111:4800

000:9600

001:19200

010:38400

011:57600

100:115200

101:230400

Remark:

1. 000000000 by default, in 

red bold

 character

2. The GATT service and AT command will support more settings than the DIP switch,

please check the page 4 section 5 and page 5 section 6.

3. Power supply:

3.1 Voltage: 5~27 VDC, 

Don’t exceed the limit.

3.2 There’re 3 ways to power the adapter: Mini USB, Terminal Block and pin9 of DB9,

please choose one.  

Don’t power the adapter by more than two sources.

3.3 The mini USB cable is inside the standard package.

4. Specifications:

4.1 Default value: (BLE Peripheral)

Baud rate: 9,600 bps

Data bit: 8

2

DIP Switch

▲ RS-485
▼ RS-422

Terminal Block

Содержание BLE-485C

Страница 1: ...ge Weight 105 g Package Contents BLE 422 485 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data...

Страница 2: ...Remark 1 000000000 by default in red bold character 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 3 Power sup...

Страница 3: ...rvice and AT command will support all the functions please check the page 4 section 5 and page 5 section 6 4 3 Range max 50 m in open space 4 4 TX Power Max 3 dBm 4 5 RX Sensitivity 89 dBm typical 4 6...

Страница 4: ...UUID UUID_Device Information 0000180A 0000 1000 8000 00805F9B34FB UUID_Firmware Revision String 00002A26 0000 1000 8000 00805F9B34FB UUID_NOTIFY 20 bytes 00031234 0000 1000 8000 00805F9B0130 UUID_RxD...

Страница 5: ...connection is ok Response ERROR when the connection is not ok AT Test the RS 232 status when first connect the adapter with the controller Default N The command will disable the auto link function In...

Страница 6: ...ice name for the adaptor You can specify a friendly name using 0 to 9 A to Z a to z space and which are all valid characters Note that first space or last space or isn t permitted The default name is...

Страница 7: ...re the current setting VERSION This command is used to inquiry the firmware version Inquire the version codes 7 RS 485 Wire connection 8 APP Download Android iOS APP Sample code Please contact the sup...

Страница 8: ...n and select one Connect and configure Data transmission test 8 Disconnect TX area RX area Data mode Clear data and log Device list Select one Enable Central Setup Reset Default Serial Port setting Ba...

Отзывы: