1. Read manual -
Carefully read the manual.
2. Installation environment -
The system should be installed indoors only. Install
either in a sturdy rack or on a table in a well-ventilated place.
3. Lightning -
Unplug the power cord during lightning or after prolonged period
of non-use to avoid damage to the equipment.
4. Maintenance
- Only qualified technical engineers or specified distributors are
permitted to repair or replace components and parts of the equipment
upon failure.
Supported Output Port (ACK Type C)
SOP7
SOP6
SOP5
SOP4
SOP3
SOP2
SOP1
SOP0
Bit = 1 if output port is supported, else 0
Supported Input Port (ACK Type C)
SIP7
SIP6
SIP5
SIP4
SIP3
SIP2
SIP1
SIP0
Bit = 1 if output port is supported, else 0
Machine Name Bytes (ACK Type C)
MN7
MN6
MN5
MN4
MN3
MN2
MN1
MN0
ASCII Code (character)
Command Table
HEX
Instruction
Code
Instruction
Description
Variable
Length Output Byte
Input Byte
Note ACK
Type
00h
Dummy Call
N
00h
00h
1
A
01h
Switch Video
Y
Video output to
switch 1 –8
(0=all)
Video input to
switch 1 – 8
(0= disconnect)
B
02h
Switch Audio
Y
Video output to
be switch 1 –8
(0=all)
Video input to be
switch 1 – 8
(0= disconnect)
B
03h
Store All
Video Status
N
00h
Memory
Location # to
store status,
(not 0)
2
A
04h
Store All
Audio Status
N
00h
Memory
Location # to
store status,
(not 0)
2
A
05h
Recall All
Video Status
N
00h
Memory
Location
#
to
recall status
from, (not 0)
2
A
06h
Recall All
Audio Status
N
00h
Memory
Location # to
recall status
from, (not 0)
2
A
07h
Request
Status of
Video Output
Y
Video output
for requested
status, (1-8, 0=
all)
Memory
Location # to get
status from
1,2
B
08h
Request
Status of
Audio Output
Y
Audi output for
requested
status, (1-8,0=
all)
Memory
Location # to get
status from
1,2
B
3Fh
Request
Machine Info
and Model
N
00h
00h
1
C
Command Note:
1. Not supported for Broadcast comand.
2. Memory #0 is current switching status, memory # 1-x is free location.
Refer to information Byte for number of total memory locations.