10
Table 1. Typical Channel Loading for ITX21-100 Input/Output Levels
2
Number Of
Channels
Input Level To Transmitter
Output Level From
Transmitter
9
31.5 dBmV/Channel
27.5 dBm/Channel
12
30.0 dBmV/Channel
26.0 dBm/Channel
18
28.0 dBmV/Channel
24.0 dBm/Channel
24
26.0 dBmV/Channel
22.0 dBm/Channel
30
25.0 dBmV/Channel
21.0 dBm/Channel
Diagnostic Connections
Diagnostic connections, not essential to the normal operation of the transmitter, are made
at the front panel of the transmitter.
RF Diagnostics
– A type N connector is provided on the front panel for the RF monitor
point. The location is shown in Figure 5.
VHF Input/Output Test Point –
VHF input and output signal test point “F” connector is
provided on the front panel. A toggle switch is used to switch between input and output
VHF signals.
Figure 5. Front Panel Connection Points.
2 See Data Manual for actual values.
Содержание ITX21-100
Страница 1: ...Cable AML Installation and Maintenance Manual Indoor Broadband Transmitter Model ITX21 100...
Страница 6: ...Indoor Broadband Transmitter ITX21 100 IM4030013 1 Rev 2 Figure 1 ITX21 100 Broadband Transmitter...
Страница 8: ...Indoor Broadband Transmitter ITX21 100 IM4030013 1 Rev 4 This Page Intentionally Left Blank...
Страница 10: ...Indoor Broadband Transmitter ITX21 100 IM4030013 1 Rev 6 This Page Intentionally Left Blank...
Страница 15: ...Indoor Broadband Transmitter ITX21 100 IM4030013 1 Rev 11 Figure 6 Rear Panel Connection Points...
Страница 16: ...Indoor Broadband Transmitter ITX21 100 IM4030013 1 Rev 12 This Page Intentionally Left Black...
Страница 22: ...Indoor Broadband Transmitter ITX21 100 IM4030013 1 Rev 18 This Page Intentionally Left Blank...