background image

3

  

REV 46577-20140214

ENGLISH

 

46577

SAfETy RULES

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.
DANGER CARBON MONOXIDE: using a generator 
indoors

 CAN KILL YOU IN MINUTES.

DANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged 

or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking.

Use approved transfer equipment to isolate generator 

from your electric utility and notify your utility 

company before connecting your generator to your 

power system.

DANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 

occur on contact. 

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least 3 ft. (91.4 cm) of clearance on all 

sides to ensure adequate cooling.

Maintain at least 5 ft. (1.5 m) of clearance from 

combustible materials.

WARNING

Medical and Life Support Uses.

In case of emergency, call 911 immediately.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

Содержание 46577

Страница 1: ...670 USA 1 877 338 0999 www championpowerequipment com Cabela s Sidney NE 69160 1 800 237 4444 www cabelas com 4000 Starting Watts 3500 Rated Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important...

Страница 2: ...s Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Care Team Toll Free at 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your product is designed and rated fo...

Страница 3: ...ltitude 13 Maintenance and Storage 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 16 Storage 16...

Страница 4: ...future reference Have this information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures accessories designed to help you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to your power system DANGER Sparks can re...

Страница 7: ...pment may create sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention...

Страница 8: ...3 8 gal 14 4 L capacity fuel tank 2 Choke Used to start the engine 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Filter Protects the engine by filtering dust and debris from the int...

Страница 9: ...power for the operation of 120 240 Volt AC single phase 60 Hz electrical loads 5 Voltage Switch Choose between 120 Volts or 240 Volts opportation 6 120 Volt AC 30 Amp Receptacle NEMA TT 30R May be use...

Страница 10: ...ps with the following parts Wheel Kit 8 in Wheel 2 Flange Bolt M10x105 for Wheel 2 Bushing 2 Flat Washer 10 2 Lock Nut M10 2 Support Leg w vibration mounts 1 Flange Bolt M8x16 for Support Leg 2 Handle...

Страница 11: ...the following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generat...

Страница 12: ...el in the crankcase falls below the threshold level CAUTION Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Da...

Страница 13: ...d by manufacture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel...

Страница 14: ...when positioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrica...

Страница 15: ...plugged in or turned on 2 Let the generator run at no load for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the Fuel Valve to the OFF position 4 Let the engine...

Страница 16: ...oximately 3 for every 1000 feet of elevation above sea level This is a natural trend and cannot be changed by adjusting the engine At high altitudes increased exhaust emissions can also result due to...

Страница 17: ...thread the plug into the engine 7 Use the spark plug tool to firmly install the plug 8 Attach the spark plug wire to the plug For service or parts assistance contact our help line at 1 877 338 0999 NO...

Страница 18: ...he end of the spark arrester to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if i...

Страница 19: ...s are disconnected from the generator 3 Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the genera...

Страница 20: ...gth 26 3 in 66 7 cm Specifications Maintenance Valve Clearance Intake 0 13 0 17 mm 0 005 0 007 in Exhaust 0 18 0 22 mm 0 007 0 009 in Note Tech bulletin regarding the valve adjustment procedure is on...

Страница 21: ...REV 46577 20140214 18 46577 ENGLISH Specifications Wiring Diagram...

Страница 22: ...15 16 17 18 19 20 21 22 23 16 24 25 26 27 28 29 30 31 32 27 33 34 35 36 37 38 39 40 41 43 44 45 47 48 50 51 52 53 59 27 67 68 69 70 75 76 77 78 79 80 85 86 73 87 88 89 90 91 92 93 94 95 97 101 102 82...

Страница 23: ...Pipe Reversal Valve 630 mm 1 49 24 070030 00 Hole Breather Tube 1 50 2 06 006 Clamp 7 1 1 51 24 070800 00 Reversal Valve 1 Part Number Description Qty 52 1 819 0510 Screw M5 10 2 53 122 072000 00 Fue...

Страница 24: ...12 13 25 26 27 29 30 32 35 37 38 12 40 41 42 43 44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 75 1 93 94 95 92 91 90 97 78 79 80 82 83 84...

Страница 25: ...21 Seal Air Cleaner 1 49 23 110006 00 Governor Rod 1 50 21 110003 00 Governor Arm 1 51 1 6177 06 Flange Nut M6 3 Part Number Description Qty 52 21 110001 00 Shaft Governor Arm 1 53 22 123000 01 Ignit...

Страница 26: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 27: ...nd or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any...

Страница 28: ...l system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be r...

Страница 29: ...ement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according to Subsection d below Any such emissions related part repai...

Страница 30: ...ets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of origin...

Отзывы: