Cut the excessive part of
the rough-in box. Keep the
top edge of the rough-in
box about 10 mm above
the finished floor.
Saw blade
Rough-in box
Flange
Locking screw
Base plate
Plug
Remove the locking screws
byS5 wrench, take out the
flange and base plate, pull
out the plugs.
Cold water outlet
Inner core
Wrench socket
Blue mark
Red mark
Towards bathtub
Hot water outlet
Make sure the inner core is
at the position as shown in
the diagram. The hot water
outlet should face towards
the bathtub.
If the inner core is not at the
correct position as shown in the
diagram 13, please adjust the
inner core with a S6 wrench.
S6 Wrench
(supplied)
Inner core
Take off protection
sheath from inner pipe
of faucet body, put on
escutcheon carefully
to avoid scratch to the
surface of faucet body.
Fix flange (the side with
counter bore back
against faucet body)
with locking screws to
faucet body firmly.
Faucet body
Inner pipe
Protection sheath
Escutcheon
Flange
Level
S5 Wrench
(supplied)
Locking
screw
Connect the inlet pipe of the
faucet body into the outlet
hole of the inner core
vertically ((attention to the
hot (red) and cold (blue)
correspondence)). The spout
of the faucet is against the
bath. Fix the faucet body
on the rough-in base with
locking screws. Adjust the
faucet body by level. Tighten
the locking screws directly
if the faucet body is upright.
Otherwise, adjust the M8
screws on the flange until the
faucet body is upright, then
tightening the locking screws.
Press the escutcheon down
on the floor.
S4 Wrench
(supplied)
M8 Screw