background image

Customer Care Australia P: 133 122 F: 1300 303 310 E: [email protected] W: cabac.com.au 

A: 8 Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected] W: cabac.co.nz

3

S-CLICK WALL TIMER MANUAL

2013 July 10th, Revision 1.3

5.2. EXAMPLE TIME SETTING (SHORT)

A desired run time after the button is pushed is 5 minutes and 30 seconds. As the long 
range will only allow time settings in 4 minute increments, the closest achievable time is 
either 4 or 8 minutes. As this is not suitable, the short range must be chosen.
To set this time, begin with all eight switches in the off (down) position. Switch 8 must 
remain off to select the short range. Switch six will set the timer longer than the desired 
time,  so  it  remains  in  the  off  position. Turn  on  (up)  switch  five  (4  minutes)  leaving  a 
remainder of 1 minute 30 seconds (5:30 - 4:00 = 1:30). Switch four would add 2 minutes, 
which is too much - leave it off. Turn on switch three (1 minute) leaving a remainder of 
30 seconds. Turn on switch two (30 seconds), giving a total of 4:00 + 1:00 + 0:30 = 5:30 
minutes. This gives the desired time, so switch one may remain off.
Switch seven may now be set for the desired button action - refer section 5.4.

1

2

3

4

5

6

7

8

4min

8min

16min 32min 64min

ON

OFF

128min

15sec

30sec

1min

2min

4min

8min

LONG:

SHORT:

SHORT

OFF

Range

LONG 

ON

Timer

Restart

“Example Timer Setting (Short)” diagram

5.3. EXAMPLE TIME SETTING (LONG)

A desired run time after the button is pushed is 36 minutes. Short range will only allow a 
maximum setting of 15 minutes and 45 seconds. As this is not suitable, we must choose 
the long range.
To set this time, begin with all eight switches in the off (down) position. Set switch 8 on 
(up) to select the long range. Switches five and six will both set the timer longer than 
the desired time, so they remain in the off position. Turn on (up) switch four (32 minutes) 
leaving a remainder of 4 minutes (36 - 32 = 4). Switches three and two would each 
add too much time - leave them off. Turn on switch one (4 minutes), giving a total of 
32 + 4 = 36 minutes. This gives the desired time.
Switch seven may now be set for the desired button action - refer section 5.4.

1

2

3

4

5

6

7

8

ON

OFF

4min

8min

16min 32min 64min 128min

15sec

30sec

1min

2min

4min

8min

LONG:

SHORT:

SHORT

OFF

Range

LONG 

ON

Timer

Restart

“Example Timer Setting (Long)” diagram

Содержание HNS210TD

Страница 1: ...l connections ACTIVE Connection to mains Active NEUTRAL Connection to mains Neutral LOAD Switched Active output connected to Load Connect Load between this terminal and Neutral EXT Connection for remotely located momentary action switches Neutral Load Active Ext Neutral Active HNS210TD Load Remote Momentary Action Switches Fig 1 Example wiring diagram HNS210TD OWNER S MANUAL Supply Voltage 220 240...

Страница 2: ...n on to indicate that power is applied to the load Pushing the push button when the load is on will either turn the load off or restart the timer depending on the configuration of the Button Action DIP switch see section 5 4 The HNS210TD can also be operated from a remote switch The remote switch will act in exactly the same way as the switch on the unit 5 SETTING THE TIMER Electrical Safety Warni...

Страница 3: ...0 5 30 minutes This gives the desired time so switch one may remain off Switch seven may now be set for the desired button action refer section 5 4 1 2 3 4 5 6 7 8 4min 8min 16min 32min 64min ON OFF 128min 15sec 30sec 1min 2min 4min 8min LONG SHORT SHORT OFF Range LONG ON Timer Restart Example Timer Setting Short diagram 5 3 EXAMPLE TIME SETTING LONG A desired run time after the button is pushed i...

Страница 4: ...ounting down the user presses the button a second time This restarts the counter back at 4 minutes and the load remains on After a further 4 minutes the load times out and turns off The load was on for a total of 7 minutes 6 WARRANTY AND DISCLAIMER CABAC warrant the product against manufacturing and material defect from the date of invoice to the initial purchaser for a period of 12 months During ...

Отзывы: