15
2.6
Connection Mains Voltage Supply
Supply Voltage from the mains has to correspond to the specifications on the typeplate.
Make sure the device is switched off.
Plug power cable in grounded socket.
i
Note!
Be aware of country-specific plug
If necessary, exchange power cable with country-specific plug!
2.7
Connection PC/Network
Connect marking laser XENO 4 by means of the patch cable included in the scope of delivery to the PC or
network.
i
Note!
When delivered, the device is configured with the fixed IP address 192.168.1.11. A functional network
connection is essential for all settings of the device.
After being switched on, the device, depending on the current configuration, connects as follows:
Direct connection to local PC
Connection in a network (LAN)
Configured with fixed
IP address:
(when delivered)
The marking laser XENO 4 is immedi-
ately ready for a connection with
cabLase Editor 5.
The marking laser XENO 4 is immediately
ready for a connection with cabLase Editor 5,
provided there is no address conflict.
In the event of an address conflict establish
direct connection to local PC and change
IP address or switch to DHCP.
Configured for DHCP:
The marking laser XENO 4 is waiting
for the assignment of an IP address via
the DHCP server of the local PC.
PC and marking laser XENO 4 are waiting for
the assignment of an IP address via the DHCP
server.
If no DHCP server is found and after a waiting time of up to 90 seconds an "automatic
private network address" will be assigned.
In this case, the address range 169.254.xxx.xxx. is used
Table 3
Possibilities of network connection
i
Note!
Also refer to chapter "Change IP Address Settings".
2.8
Connection Safety Circuit and Emergency Stop
For the operation of the marking laser XENO 4 special safety installations are necessary whose extend depend on
the specific use. The following conditions must be fulfilled:
• Connection of a safety interlock according to DIN EN 60825-1 at the
Interface Interlock / E-Stop - CON4.
• Connection of an Emergency Stop at the
Interface Interlock / E-Stop - CON4.
i
Note!
Operation of the marking laser is only possible with activated safety interlock and not activated Emergency
Stop.