FA00946M4A - 11/2017
FA00946M4A - 11/2017
Functional checks
Issue a start command (each RIO accessory will fl ash * blue)
Make sure that the RIOLX8WS activates.
Interfere with the gate's opening or closing and check
whether the RIOPH8WS and/or RIOED8W devices activate
the required safety function.
When the maneuver is complete, each RIO accessory will
fl ash* red and switch into LOW POWER mode to preserve
the batteries.
⚠
In LOW POWER mode, the photocells will respond
more slowly - the LED fl ashes blue - to the manual op-
eration test.
* If this does not happen, cut off the mains power supply
and increase the radio signal's range/power by setting
jumper
③
to position H.
Troubleshooting
Alerts
Possible causes
Fix
No RIO accessory is
saved.
Confi gure RIO
accessories.
The photocells:
a. detect an
obstruction;
b. are misaligned;
c. have fl at bat-
teries.
a. Remove the
obstruction.
b. Align the photo-
cells.
c. Replace the
batteries.
The sensitive
safety-edge does
not intervene.
Check settings
and adjustments
on the sensitive
safety-edge.
LED on, steady LED off LED fl ashes
Buzzer active