Product information Wireless data loggers
Installation
The practical wall mount plastic support allows quickly removing and replacing the devices of the system for service operations, for
example to change the battery or to periodically check the calibration at a laboratory. Alternatively, a fixed installation can be realized,
using the appropriate anodized aluminium alloy flanges to be fixed on the back of the instrument case. The use of the flanges makes it
possible to prevent the removal of the instrument thanks to the possibility of applying a security padlock, inserted in a pin to be fixed
to the wall.
Padlock
Pin
Flange
Plastic support
Flanges and security padlock
Conformities
The data loggers are in compliance with the standard
EN 12830
. The PC application software
HD35AP-S
(advanced version with HD35AP-
CFR21 option) is designed in accordance with the
FDA 21 CFR part 11
recommendations.
The display in the data loggers with optional LCD
Depending on the data logger model, the LCD is custom or graphic type. The models with custom LCD are identified by the
L
letter in
the code. The models with graphic LCD are identified by the
G
letter in the code.
All the various quantities measured and calculated by the data logger can be viewed on the LCD. In the models with custom LCD that
measure various quantities, the temperature is displayed in the secondary row.
Indications on the status of connection, logging (running/disabled) and battery charge level are provided.
Primary row
Battery
level
Logging
status
Secondary
row
Connection
status
Custom LCD
The models with graphic LCD allow viewing 3 measures at the same time in the secondary rows. The graphic display also shows the level
of the RF signal, date and time.
Logging status
Battery level
Date
Secondary rows
Connection status
RF signal level
Time
Primary row
Graphic LCD
The data loggers with LCD can display the measured values in different units of measurement. For example, in the models measuring
temperature the user can set °C or °F, or, in the models measuring atmospheric pressure, the unit of measurement can be set by the
user in: hPa (= mbar), mmHg, inchHg, mmH
2
O, inchH
2
O, atm.
The possibility to view information on the quality of the RF signal (Received Signal Strength Indication, Packet Error Rate) allows an easy
positioning of the devices during system installation.
20