SLAVE OVERDOOR LIGHTS

Slave overdoor lights comprise two red and two green ultra-bright LEDs
inside a triangular diffuser.  They offer low current consumption and
connect to call points via four cores (Two cores are the same as the two
network wires so connection to the network can be made at the
overdoor light or the call point).

QT606 .................. Quantec Overdoor Light

CEILING PULLS

Ceiling pulls have a red confidence light and a 3m cord with
two open-sided triangular pulls specially designed for ease of
use by the infirm.  Four knockouts are provided for 16mm square
mini trunking and the backplate fits BESA centres.  They
are generally reset at a call point to which they connect via
three cores.

QT607 .................. Quantec Ceiling Pull

SLAVE CALL POINTS

Slave call points are functionally the same as ceiling pulls and as such must
be used in conjunction with a master call point.  Comprising a call button,
remote socket and confidence light, they are designed for use in areas
such as double bedrooms where more than one call button may be
required.  All calls must be reset at the master.

QT602D ................ Quantec Slave Call Point

TAIL CALL BUTTONS

Tail call buttons consist of a pear-shaped push, a lead and a plug
that connects it to a call point’s remote socket.  A call is made by
pressing the button or by pulling the plug out.  Tail call leads are
available in a variety of different lengths (as indicated below) to
suit different applications.

NC805C/6 ............. 1.8m (6ft) tail call button with right angle plug
NC805C/14 ........... 4.2m (14ft) tail call button with right angle plug
NC805D ................ 1.2-3.6m (4-12ft) tail call button with coiled lead

HAND/FOOT OPERATED PNEUMATIC PADS

Ideal for patients who find it difficult to press buttons,
Quantec’s hand/foot operated pneumatic pad must be
used in conjunction with the NC805AS air switch.
Applying pressure to the pad operates the air switch
which, when connected to a call point’s remote socket,
triggers a call.

NC805P ................ Hand/Foot Operated Pneumatic Pad
NC805AS .............. Remote Air Switch, for use with NC805P

ANCILLARY DEVICES

CALL

Q

Approved Document No: DNSQ100101 Rev 6 • Page 9 of 16

Содержание QT302RXS

Страница 1: ...A GUIDE TO Quantec Approved Document No DNSQ100101 Rev 6 Page 1 of 16 a d d r e s s a b l e c a l l s y s t e m...

Страница 2: ...s 6 Displays 7 Infrared ceiling receivers 7 Radio receivers 7 RF integrity transmitters 7 Addressable overdoor lights addressable sounders 8 Quantec controller 8 ANCILLARY DEVICES 9 Slave overdoor lig...

Страница 3: ...anning and displays can be fitted virtually anywhere to suit the application However whilst simplifying things for the installer some addressable systems still fail to satisfy the varied needs of the...

Страница 4: ...ting them to visit a display RESET As the member of staff leaves the room the call point s RESET button is pressed again to take it out of Staff Presence mode and returning it to normal If preferred m...

Страница 5: ...C DIVERT If a call remains unanswered for a preset time 1 8 mins to ensure it does not remain unattended indefinitely the system can be set up to automatically divert it to other areas MANUAL DIVERT I...

Страница 6: ...sounder QT602R Quantec call point button reset with I R receiver QT602RS Quantec call point button reset with sounder I R receiver QT602M Quantec call point magnetic reset QT602SM Quantec call point m...

Страница 7: ...eivers are designed for use with Quantec s QT412 range of dual action infrared radio transmitters see page 10 Dependent on the transmitter s used they allow standard and or attack calls to be made fro...

Страница 8: ...the Controller for assigning to network devices The library of 45 pre set names consists of the following Annex Area Bathroom Bedroom Conservatory Corridor Dining room Disabled WC Display Door Doorbel...

Страница 9: ...esigned for use in areas such as double bedrooms where more than one call button may be required All calls must be reset at the master QT602D Quantec Slave Call Point TAIL CALL BUTTONS Tail call butto...

Страница 10: ...dual site QT412RXA Dual action infrared radio transmitter configuredforpushforattack pullforattack QT412RXCA Dual action infrared radio transmitter configured for push for call pull for attack QT424 1...

Страница 11: ...ted to When deciding on the position of Infrared Ceiling Receivers take into account the 10 metres line of sight transmitting range of infrared transmitters Use slave receivers in large open areas lon...

Страница 12: ...ed in four or six core security cable In excess of 60 addressable devices can be connected to each network splitter Consequently four splitters are capable of accommodating an entire system However fo...

Страница 13: ...e stranded alarm cable Max 3 x QT302RXs per master ceiling receiver A maximum of 10 network devices can be connected to each of the QT603s 6 outputs 240V a c QT600P Printer Kit wall socket lead pre te...

Страница 14: ...410mm 250mm 80mm Quantec controller lid 439mm 274mm 7mm Radio receivers 271mm 155mm 170mm All single gang devices 87mm x 87mm mount on 25mm single gang UK back boxes All double gang devices 146mm x 8...

Страница 15: ...o offer an in depth understanding of the installation maintenance and commissioning of the Quantec addressable call system Held regularly at the manufacturer s headquarters in the north west of Englan...

Страница 16: ...een carefully checked prior to publication However no responsibility can be accepted by the Manufacturer or Distributor s of the Quantec system for any inaccuracies or for any misinterpretation of an...

Отзывы: