On the majority of inland sites the ground control should be set to AUTO 
and the recommended sensitivity setting between 7-9 on the scale will give 
the best results. Some types of ground may give rise to false signals and the 
sensitivity level should be reduced to a point where operation of the detector 
becomes stable. 

Sweep the detector head from side to side with a steady relaxed motion. 
Keep the search-head parallel and as close as possible to the ground right 
across the arc of the sweep. 

Search your chosen site carefully by moving forward only the width of the 
search-head at each sweep. Move up and down the search area in lines so 
that there is plenty of overlap in the ground you have covered. Search with the 
sensitivity set as high as possible according to the ground conditions. 

Setting the GROUND control.

Experienced users can achieve a higher level of sensitivity by setting 
the ground control manually.

With GROUND set to AUTO, DISC VOL and IRON VOL set to maximum 
and with DISC set to minimum, find an area which is free from metal.

a) Switch the GROUND control out of the AUTO setting to position 1.
b) Start sweeping the search head from side to side. Whilst sweeping, 
increase the GROUND control setting until the low (iron) tone disappears. 
You have now ground excluded the CS6MX for that area.
c) Reset the DISC VOL, IRON VOL and DISC to your preferred settings.

Detecting with the CS6MX

Содержание CS6MXi

Страница 1: ...CS6MX Operating Instructions...

Страница 2: ...AA battery holder 11 Battery contacts 12 Search head socket 13 Search head plug 14 Control box 15 Hand grip 16 Upper stem 17 Arm support 18 Detector rest 19 Stem lock 20 Lower stem 21 Interchangeable...

Страница 3: ...d or mineralised sites The CS6MX provides the option of interchangeable search heads to optimise performance on a variety of site conditions There is an iron volume control alongside a discrimination...

Страница 4: ...eful to observe polarity and good contact and replace cover 7 Rotate the Iron Volume control to number 8 on the scale 8 Rotate the Disc control to number 4 on the scale 9 Rotate the Disc Volume contro...

Страница 5: ...hinery and iron stakes tend to give positive signals even when the detector is set to high discrimination settings Once the pinpoint switch is released the detector returns to motion mode 4 Iron Volum...

Страница 6: ...ormal standing position Tighten the wing nut on the search head retaining screw Do not over tighten Friction of the head lugs against the neoprene washers keeps the search head in position Excessive p...

Страница 7: ...eight good quality AA type batteries into the compartments of the battery holder Observe polarity of the batteries the spring contact goes against the flat negative end of the battery Roll the batter...

Страница 8: ...ove up and down the search area in lines so that there is plenty of overlap in the ground you have covered Search with the sensitivity set as high as possible according to the ground conditions Settin...

Страница 9: ...he hole or in the piece of earth which you have just removed Dig some more and sift through the earth until you find what you are looking for Fill in the hole before moving on The use of headphones wi...

Страница 10: ...th of detection For these reasons it is best to keep the discrimination setting as low as possible Depending on how the controls are set the CS6MX can be set to ignore signals from certain types of me...

Страница 11: ...e end of a day s detecting Do not use solvents If the detector has been used on a beach it will be necessary to wash sand and salt residue off the stem adjustment mechanism and the search head retaini...