Follow these simple steps to start using the CS6MX within minutes:
1) Insert the lower stem into the upper stem (first press in the spring clip).
2) Twist the locking device so that the stem is locked at the required length.
3) Coil the search-head lead around the stem.
4) Plug the search-head lead into the socket on the control box.
5) Remove the battery compartment cover by loosening the four retaining screws.
6) Fit 8 x AA batteries to the battery holder being careful to observe polarity
and good contact and replace cover.
7) Rotate the Iron Volume control to number 8 on the scale.
8) Rotate the Disc control to number 4 on the scale.
9) Rotate the Disc Volume control to number 8 on the scale.
10) Set the Ground Control to ‘AUTO’.
11) Switch on and rotate the Sensitivity control to number 8 on the scale.
12) START DETECTING... Good metal targets give a sharp, high pitched audio
tone from the loudspeaker... Targets that have been discriminated will be identified
by a mid frequency tone... Signals from small pieces of iron are identified by a low
frequency tone... Switch to pinpoint to identify the exact position of the target.