C Prox Ltd PN10 Скачать руководство пользователя страница 5

 

9.5.2  Use card number to delete user 

 

.

2

.  .

Card number

.  .

#

.  .

Card number

.  .

#

 …  

.

#

Multiple cards can be deleted without exiting programming mode. 

9.5.3  Delete all users 

 

.

2

.  .

0000

.  .

#

.  

Note: This operation will delete all users, but admin card won’t be deleted. 

9.6  Safe mode setting 

 

9.6.1  Normal mode (Factory default) 

 

.

3

.  .

0

.  .

#

.  

9.6.1  Dead mode  

 

.

3

.  .

1

.  .

#

.  

Read invalid card 10 times continuously within 10 minutes, the device will be dead for 10 minutes. 

9.6.2  Alarm mode  

 

.

3

.  .

2

.  .

#

.  

Read invalid card 10 times continuously within 10 minutes, both the built-in buzzer and external alarm sound. 

9.7  Door open time setting 

 

.

4

.  .

0 - 99

.  .

#

.  

Note: Range is 0 – 99 seconds. 0s equates to 50Ms. 

9.8  Alarm time setting 

 

.

5

.  .

0 - 3

.  .

#

.  

Note: Range is 0 – 3 minutes. Factory default is 1 minute. 

9.9  Red light mode setting 

 

9.9.1  Standby disable mode (red light is off when device is on standby) 

 

.

6

.  .

0

.  .

#

.  

9.9.2  Standby normal mode (red light flashes when device is on standby, factory default) 

 

.

6

.  .

1

.  .

#

.  

9.10  Interlock mode setting 

 

9.10.1  Interlock disabled (factory default) 

 

.

7

.  .

0

.  .

#

.  

9.10.2  Interlock enabled 

 

.

7

.  .

1

.  .

#

.  

9.11  Anti-passback mode setting 

 

9.11.1  Anti-passback disabled (factory default) 

 

.

8

.  .

0

.  .

#

.  

9.11.2  Anti-passback host mode enabled 

 

.

8

.  .

1

.  .

#

.  

9.11.2  Anti-passback subsidiary mode enabled 

 

.

8

.  .

2

.  .

#

.  

Note: Details will be illustrated in the advanced application section below. 

 

Содержание PN10

Страница 1: ...inc Quantek 59 Sheffield Road Dronfield S18 2GF 44 0 1246 417113 sales cproxltd com www quantek co uk Access Control Proximity Reader PN10 User Manual Please read the manual carefully before installi...

Страница 2: ...lost cards Two units can also be interlocked It has low power consumption anti theft alarm and door release button all these make it convenient safe and reliable 3 Features Zinc alloy anti vandal she...

Страница 3: ...it the reader into the back plate and replace retaining screw 6 Wiring Colour Function Description Pink RESET Reset Pink RESET Reset Green D0 WG output D0 White D1 WG output D1 Grey ALARM Alarm negati...

Страница 4: ...card Read user card 1 Read user card 2 Read admin add card 9 1 2 Delete user via admin card Read admin delete card Read user card 1 Read user card 2 Read admin delete card 9 2 Enter into programming...

Страница 5: ...nal alarm sound 9 7 Door open time setting 4 0 99 Note Range is 0 99 seconds 0s equates to 50Ms 9 8 Alarm time setting 5 0 3 Note Range is 0 3 minutes Factory default is 1 minute 9 9 Red light mode se...

Страница 6: ...controller PN10 supports Wiegand output It can be connected to a controller which supports Wiegand 26 input as its slave reader 11 2 PN10 works as a controller connecting to a slave reader PN10 suppo...

Страница 7: ...can be communicated so in this case the user capacity for one door can be 20 000 The setting of both devices must be the same If the master codes were different the user enrolled in the outdoor unit...

Страница 8: ...te 11 4 Two devices interconnected with anti passback Two doors Install one device on door 1 under anti passback subsidiary mode Install one device on door 2 under anti passback host mode This functio...

Отзывы: