C.Plath navipilot V HSC Скачать руководство пользователя страница 10

Quick Reference Guide

Page 10 of 12

15 MAR 2001 REV C

NAVIPILOT V HSC

N AV I G AT I O N  A U TO M AT I O N

.

056300          8-151

max. permitted rate of turn

6

4

6

4

6

4

6

4

6

4

6

4

rel. integration time constant (I )

t

following sea pulse duration (FSP)

following sea rudder angle (FSA)

rudder engine dead band

rudder engine type

30 °/min. - 1999 °/min.

0% - 300%

0% - 90% (percent of )

τ

0° - 5°

0° - 10°

= analogue rudder control
= bang-bang-control (solenoid valves)

An

bb

6

4

20° - 35°

max. rudder angle

contd. on next page

contd. from previous page

Service setup 2 (contd.)

Содержание navipilot V HSC

Страница 1: ... to next waypoint from nav receiver INS 2 On course change alarm press to receive course to next waypoint 1 Press to return to autopilot steering mode Displays act heading display actual heading from gyrocompass mode gyro magnetic compass mode mag set heading course display autopilot set heading mode auto commanded course to steer mode nav act heading manual steering mode rudder angle display rudd...

Страница 2: ...difference between gyrocompass heading and magnetic compass heading exceeds limit POWER FAILURE failure in power supply FAILURE INTERF Hd6 Hd6 Hd6 Hd6 Hd6 no valid data at gyro or magnetic compass interface 5Pd 5Pd 5Pd 5Pd 5Pd speed interface nAu nAu nAu nAu nAu NAV interface Nav receiver 1n5 1n5 1n5 1n5 1n5 NAV interface INS Mute audible alarm 7 On alarm press to mute alarm buzzer Alarm status at...

Страница 3: ...ode Magnetic Variation 6 4 MAGNETIC VARIATION 99 W 99 E Steering Strategy 6 4 WEATHER confined waters open sea rough sea Rate of Turn Turn Radius 6 4 RATE min RADIUS nm 1 max min 1999 nm In normal operational mode switch to enter mode A automatic M manual 5 99 kts Speed M 6 4 4 6 A SPEED kt 1 In enter mode leave enter mode immediately and return to normal operational mode Load 6 4 LOAD 0 100 6 5 3...

Страница 4: ... 0 7 6 rudder parameters load 6 4 LOAD 0 100 6 LOAD RATE min RADIUS nm rate of turn turn radius 6 4 rate of turn turn radius rot rd5 6 magnetic compass display format 6 4 1 1 0 6 7 contd on next page In normal operational mode press simultaneously to access user setup counter rudder 0 1 5 0 cr 4 6 accessible in manual steering mode only ...

Страница 5: ...6 Hr 6 4 Nin 4 Yr 30 180 00 99 01 12 01 31 00 23 00 59 daY 4 printing off printing on 0FF 0n 7 6 9 45 70 contd from previous page heading scale rudder scale paper feed date year date month date day time hours time minutes 7 6 6 1 In user setup quit user setup immediately and return to normal operational mode 6 quit user setup and return to normal operational mode end user setup User setup contd ...

Страница 6: ...s access code service setup 1 code 6 cross track error sensitivity with relevant NAV interface protocols only 0 20 magnetic compass calibration calibration off calibration on 0FF 0n 8 9 5 4 6 0 359 magnetic heading value 20 20 correction value store hdg corr value in calibration table 6 0FF 0n 6 4 6 4 4 6 7 clear entry from calibration table contd on next page Service setup 1 ...

Страница 7: ...e setup 1 contd min display brightness 1 40 max display brightness 6 4 6 4 1 In service setup quit service setup immediately and return to normal operational mode 6 4 switchover mode master remote internal external 1nt Port quit service setup and return to normal operational mode 60 100 contd from previous page ...

Страница 8: ...ON 056300 8 151 Service setup 2 8 7 In normal operational mode press simultaneously to access service setup modes access code 6 4 6 4 6 4 6 4 time constant tau τ cruising speed U 0 ext off course alarm delay service setup 2 code 7 2 sec 80 sec 5 kts 99 kts 0 sec 300 sec contd on next page ...

Страница 9: ...data 4 VECTOR INS data 5 DB 2000 INS data 6 INS 970 INS data 7 VMS for service only 0FF H5C bod APA APb Ct5 PCt bPi bur buc 1n5 1n5 1n5 1n5 1n5 1n5 1n5 5Er 1 2 3 4 5 6 7 u 6 4 magnetic compass interface format interface disabled fluxgate sensor sin cos type NMEA 0183 for service only 0FF 5in Co5 183 tE5t 6 4 gyrocompass interface format interface disabled 6 step 12 step synchro 1 360 Plath format ...

Страница 10: ...4 6 4 rel integration time constant I t following sea pulse duration FSP following sea rudder angle FSA rudder engine dead band rudder engine type 30 min 1999 min 0 300 0 90 percent of τ 0 5 0 10 analogue rudder control bang bang control solenoid valves An bb 6 4 20 35 max rudder angle contd on next page contd from previous page Service setup 2 contd ...

Страница 11: ... gyro magnetic 50 mV 300 mV input disabled turn 180 port stbd turn hdg display 180 alter set hdg port stbd tiller or pushbuttons 0FF tur 180 5tE n P L0Ad select load state internal from control master only internal from all operating units external 1nt M 1nt ALL Port 1 In service setup quit service setup immediately and return to normal operational mode contd from previous page Service setup 2 con...

Страница 12: ...Quick Reference Guide Page 12 of 12 15 MAR 2001 REV C NAVIPILOT V HSC NAVIGATION AUTOMATION 056300 8 151 This page intentionally left blank ...

Отзывы: