27
Cable locator
Precautions
For the sake of safety, the power supply of electrical equipment must be
turned off.
SUGGESTIONS
1. The ground end of the emitter must be some distance away from the pipe
to be detected. If the distance is too short, the signals and the circuit cannot
be precisely located.
2. In the pipeline detection process, the stronger the signals displayed on the
Nixie tube of the detector, the closer the pipe is to be detected.
3. Select the receiver's manual mode and an appropriate sensitivity to
precisely locate the pipe.
4. To detect a pipe made of non-conductive materials, we suggest inserting a
helical metal tube first into the pipe, as described in Section 3.1.6.
3.1.8 Detection of the supply circuit on the same floor
To detect the power circuit in the same plant please follow the following
steps:
1) Turn off the main switch of the distribution board of this plant,
2) Disconnect the neutral wire of the distribution board of this plant, from the
neutrals of other plants.
3) Connect the emitter as shown in Fig. 3-1-8.