background image

Document:  

Date

Created By: 

 

 

  LPN00855X0001A0_A  

  04-21-2021

TMT 

INSTALLATION INSTRUCTIONS

C-WP-C-TR Series

http://lighting.cree.com/warranty      |    1-800-236-6800     

CAUTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER

 – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This Product Must Be Installed In Accordance With The 

Applicable Installation Code By A Person Familiar With 

The Construction And Operation Of The Product And The 

Hazards Involved. 

Ce Produit Doit Être Installé Selon Le Code D’installation 

Pertinent, Par Une Personne Qui Connaît Bien Le 

Produit Et Son Fonctionnement Ainsi Que Les Risques 

Inhérents. 

3.  Wall Mount Only. 

INSTALLATION MURALE SEULEMENT

4.  Suitable for wet locations. 

Convient aux emplacements mouilles.

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE 

MOUNTING OVER RECESSED JUNCTION BOX

NOTE:

 Knockouts are provided for mounting over 3" octagonal, 4" oc-

tagonal, or 4" square junction boxes.

1.  Remove lens assembly by loosening screws on side of frame. Do 

not loosen tamper proof screws on hinge side of frame. Swing lens 

assembly open,disconnect quick connect wiring connector(s) and 

lift lens assembly upward to remove from housing.

2.  Drill out appropriate knockouts in back box for attachment to junction 

box. Also drill knockout for wiring access.

NOTE: 

Luminaire should not be exclusively supported by junction 

box. Drill knockouts in lower two corners and center top of back box 

to allow for attachment of back box to mounting surface.

3.  Pull supply leads from junction box through wall of back box. Attach 

back box to mounting surface using hardware (supplied by others) 

appropriate for mounting surface.

NOTE:

 A high grade caulking material, such as silicone rubber, 

should be used around perimeter of back box (between back box and 

mounting surface) to prevent water leakage into luminaire or junction 

box.

4.  Replace lens assembly on hinges and re-connect quick-connect 

wiring connections.

5.  Position dip switches to select desired CCT and wattage. See  

Figure 1. 

NOTE: 

Dip switches factory set at highest wattage and 4000K

.

6.  Make wiring connections per the 

Electrical Connections

 section.

7.  Swing lens into place. Re-tighten screws that were loosened in Step 

1.

8.  Supply power to luminaire.

1.  Remove lens assembly by loosening screws on side of frame. Do 

not loosen tamper proof screws on hinge side of frame. Swing lens 

assembly open,disconnect quick connect wiring connector(s) and lift 

lens assembly upward to remove from housing.

2.  Drill knockouts in lower two corners and center top of back box to 

allow for attachment of back box to mounting surface.

3.  Attach back box to mounting surface using hardware (supplied by 

others) appropriate for mounting surface.

NOTE:

 A high grade caulking material, such as silicone rubber, 

should be used around perimeter of back box (between back box and 

mounting surface) to prevent water entry.

4.  Remove appropriate threaded plugs on sides of fixture and route 

electrical conduit to the holes desired. Feed the supply leads through 

the conduit and into the back box.

NOTE:

 Use of teflon tape on the conduit threads will ensure a 

watertight seal.

5.  Replace lens assembly on hinges and re-connect quick-connect 

wiring connections.

6.  Position dip switches to select desired CCT and wattage. See  

Figure 1. 

NOTE: 

Dip switches factory set at highest wattage and 4000K

.

7.  Make wiring connections per the 

Electrical Connections

 section.

8.  Swing lens into place. Re-tighten screws that were loosened in Step 

1.

9.  Supply power to luminaire.

WALL MOUNTED WITH CONDUIT FEED

FIGURE 1

CCT Selection

Wattage Selection

Содержание C-WP-C-TR Series

Страница 1: ...lied by others appropriate for mounting surface NOTE A high grade caulking material such as silicone rubber should be used around perimeter of back box between back box and mounting surface to prevent...

Страница 2: ...st 24 hours before conducting a long term test STEP 1 When AC power is applied the charging indicator light is illuminated indicating the battery is being charged When power fails the emergency driver...

Страница 3: ...Connect ground bare or green wire lead to the supply ground lead STEP 2 Turn on unswitched voltage supply to luminaire Keep the switched voltage supply to luminaire off STEP 3 Connect the battery fema...

Страница 4: ...TA Se debe usar un sellador de alta calidad como el sellador de silicona alrededor del per metro de la caja trasera entre la caja trasera y la superficie de montaje para evitar que entre agua a la lum...

Страница 5: ...icadora de carga se ilumina indicando que la bater a se est cargando Cuando falla la energ a el controlador de emergencia cambia autom ticamente a energ a de emergencia haciendo funcionar la matriz de...

Страница 6: ...verde con el cable de tierra del suministro PASO 2 Encienda el suministro de voltaje no conmutado a la luminaria Mantenga apagado el suministro de voltaje conmutado a la luminaria PASO 3 Conecte el c...

Страница 7: ...chouc de silicone doit tre utilis autour du p rim tre de la bo te arri re entre la bo te arri re et la surface de montage pour emp cher toute fuite d eau dans le luminaire ou la bo te de jonction 4 Re...

Страница 8: ...alimentation en alternatif est appliqu e le voyant de charge s allume indiquant que la batterie est en charge En cas de panne de courant le pilote d urgence passe automatiquement en mode d alimentati...

Страница 9: ...u vert au fil de terre de l alimentation TAPE 2 Allumez l alimentation en tension non commut e du luminaire Maintenez coup e l alimentation en tension commut e du luminaire TAPE 3 Sur le pilote d urge...

Отзывы: