20
Remove the three cable clips
which hold the sensor power
cable in place by unscrewing
the M6 bolts
Two are located on the right
hand side of the frame and
one is located on the
underside of the top
crossmember
Remove the cable from the
actuator by undoing the M10
shoulder bolt on the moving
end of the actuator.
With this end free, you can
now lift the actuator slightly
in order to access the
TORX25 screw which holds
the actuator cover/cable in
place
Содержание pasture meter+
Страница 1: ...1 Operation Manual Version 2400 6640 7 July 2022...
Страница 30: ...23 This section contains Exploded parts diagram Parts list SECTION 5 Parts...
Страница 31: ...24 Exploded Parts Diagram...
Страница 33: ...26 This section contains DIY Calibration Method Seasonal Equations SECTION 6 Quick Reference...