TROUBLESHOOTING GUIDE

SYMPTOMS

POSSIBLE CAUSES

SOLUTIONS

The LCD display is
faulty when the power
is first turned on.

Static hangup.

Remove all batteries.
Unplug the jack and wait
5 seconds before
plugging the unit in again.

Battery charging starts
before the lid is closed.

Pressing the
DISCHARGE OVER-
RIDE button does not
stop the discharge
cycle.

Pressing and holding
the DISCHARGE
OVERRIDE  button for
3 seconds does not
switch to IDS mode.

Defective unit.

Contact your dealer.

Defective unit.

Contact your dealer.

Some of the recharged
batteries have a low
battery life or no output
at all.

Display shows

More than one battery
being recharged at the
same time. Some are
loose or have bad
contact.

Put those batteries back
into the charger and close
the lid to recharge again.
See Revitalizing NiCad
Batteries on page 8.

Bad battery

Properly dispose of the
faulty battery.

Charger is not in Soft-
Start Charging mode.

Press and hold
DISCHARGE OVERRIDE
button for 3 seconds to
switch to IDS mode only
in Soft-Start mode.

Bad battery

Properly dispose of the
faulty battery.

Содержание QuickCharger

Страница 1: ...Operating Instructions...

Страница 2: ...the risk of fire electric shock or other personal injury Do not disassemble the charger It should be serviced or repaired by qualified service personnel only Incorrect assembly may result in an electr...

Страница 3: ...ersatile battery charger made Its highly sophisticated microprocessor controlled system quickly charges batteries without creating damaging heat Its discharge circuit conditions batteries to improve c...

Страница 4: ...d then the Loading symbol will flash indicating the Charger is ready to use 4 Open the lid using both hands Install up to four batteries of the same size and type as indicated with the negative side t...

Страница 5: ...the charger With the lid open press the Battery Analyzer Button Within ten seconds the QuickCharger will display the battery capacity and voltage The number of bars displayed in the battery icon will...

Страница 6: ...battery capacity may be reduced over time due to the memory effect Theoretically you do not need to discharge NiMH batteries although it seems to bring them up to full performance faster when they ar...

Страница 7: ...ur Battery Symbol bars on the left will remain on and the fifth bar will flash as the Top Off Trickle Charge symbol flashes from left to right The batteries are 85 to 90 charged at this point When the...

Страница 8: ...ry Size Capacity mAh Approximate Charging Times 2 Batteries 4 Batteries NiMH charging without IDS AAA AA C D 600 1600 4500 9000 1 Hr 20 Min 2 Hrs 27 Min 4 Hrs 33 Min 8 Hrs 2 Hrs 40 Min 4 Hrs 54 Min 9...

Страница 9: ...ter 10 seconds i e the display anima tion is still running ANALYZE button held Release the ANALYZE button Defective unit Contact your dealer Battery short circuit Remove the bad battery and insert ano...

Страница 10: ...to IDS mode Defective unit Contact your dealer Defective unit Contact your dealer Some of the recharged batteries have a low battery life or no output at all Display shows More than one battery being...

Страница 11: ...hould service be required 1 Remove the batteries if applicable and carefully pack the unit along with the AC power cord in original packing cartons or a suitable well padded corrugated box 2 Enclose a...

Отзывы: