Rev F
Housing Instructions
3-13
3
Figure 3.9
Heatshrink Boot
4. Prepare the coaxial cable for attachment:
a. Prepare the cable end as recommended by the connector manufacturer.
b. Measure the center conductor length as shown in Figure 3.10.
c.
Ensure that the center conductor length is at least 1 1/8 inches (2.71 cm). If the center
conductor is longer than 1 1/4 inches (3.30 cm), trim it with wire cutters to between 1
1/8 and 1 1/4 inches (2.71cm and 3.30 cm) to avoid unintentional signal grounding.
Figure 3.10
Cable Connector
Assembly
5. Apply anti-seize compound to threads and O-ring. Do
not
use spray lubricant.
CAUTION
: Do not use feed-through type connectors. Use pin type connectors only.
Using connectors with center conductors exceeding 0.080 inches (2.03 mm) in diameter
will damage the centerseizure mechanism.
Entry Port
2 in (5.08 cm
)
Back Nut
Main Nut
Connector Body
Radiation
Sleeve
O-rings
Variations:
External threads
located on back nut.
Main Nut/Connector Body
Back Nut
Minimum: 1 1/8 in. (2.71cm)
Maximum: 1 1/4 in. (3.30cm)
Not more than
0.080 in.
(2.03 mm)
diameter
Содержание FlexNet E7
Страница 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...
Страница 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1...
Страница 23: ...Rev F Physical Identification 2 7 2 Figure 2 6 E629 Line Extender 19 4 5 3 21 17 20 14 13 13 16...
Страница 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2...
Страница 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4...
Страница 82: ...A 6 FlexNet 700 Series Line Extender Rev F A...
Страница 88: ...B 6 FlexNet 700 Series Line Extender Rev F B...
Страница 102: ...C 14 FlexNet 700 Series Line Extender Rev F C...
Страница 104: ...D 2 FlexNet 700 Series Line Extender Rev F D...
Страница 110: ...Index 4 Rev F...
Страница 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...