4-14
FlexNet
®
700 Series Line Extender
Rev F
4
Two Person Return Balancing Procedure
➤
To balance the return path
1. Obtain the Return High and Low Balancing Carrier Levels from the System Map for both
amplifiers. Record these levels in the corresponding boxes on the
and as indicated in the calculation boxes of Steps 3, 4, and 7.
2. Set the E7 Line Extender as follows:
a. At the Balancing Amplifier, ensure that factory jumpers (stripline) or SPB-0 /SEQ-0
accessories are installed in the
REVERSE PAD
and
REVERSE EQ
locations.
b. Remove the plug-in terminator (SPB-99), if present.
Figure 4.4
Simplified Return
Path Block Diagram
3. Equalize the RF signal (use calculation box next page):
a. At the Balancing Amplifier, connect a signal generator to the Port 3 testpoint.
b. Set the Signal Generator to output the system Return High and Low Balancing carriers
(plus 25 dB to compensate for the RF module testpoint loss; see the housing label for
testpoint loss.)
c.
At the Measuring Amplifier, connect a Signal Level Meter (SLM) to the Port 3 external
testpoint. Measure the Return High and Low Balancing Carrier Levels and record them
as shown in the following calculation box.
d. Calculate the Equalization Value. Using the appropriate table in Appendix C, select an
MEQ plug-in accessory that has a tilt as close to the Equalization Value as possible. For
a full explanation of the selection process, see
When the Equalization Value is Known
e. If necessary, at the Balancing Amplifier, remove the SEQ-0 or factory jumper (stripline)
from the
REVERSE EQ
plug-in area. Install the selected MEQ into the
REVERSE EQ
plug-in area.
CAUTION
: RF signal levels greater than +30dBmV at the hybrid can damage amplifier
active components. Do not use signal levels greater than +30dBmV at the hybrid.
(+30 dBmV = +90dBµV).
Note
: The two person method of return balancing requires two technicians
communicating between two successive amplifier locations. Balancing signals are
injected into the Port 3 external testpoint of the Balancing Amplifier and measured at the
Port 3 external testpoint of the Measuring Amplifier.
Note
: FlexNet 700 Series line extender testpoints are -25 dB referenced to the associated
port input or output level. Stickers on the E7 Line Extender housing indicate testpoint
value.
Note
: C-COR provides a plug-in terminator (SPB-99) in the return path to prevent a
buildup of noise that can be transmitted through the return path. The return path is not
active until the plug-in terminator is removed and striplines, PADs, or accessories are
installed.
Port 1
Port 3
REVERSE PAD
REVERSE EQ
Содержание FlexNet E629
Страница 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM ...
Страница 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1 ...
Страница 23: ...Rev F Physical Identification 2 7 2 Figure 2 6 E629 Line Extender 19 4 5 3 21 17 20 14 13 13 16 ...
Страница 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2 ...
Страница 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4 ...
Страница 82: ...A 6 FlexNet 700 Series Line Extender Rev F A ...
Страница 88: ...B 6 FlexNet 700 Series Line Extender Rev F B ...
Страница 102: ...C 14 FlexNet 700 Series Line Extender Rev F C ...
Страница 104: ...D 2 FlexNet 700 Series Line Extender Rev F D ...
Страница 110: ...Index 4 Rev F ...
Страница 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM ...