![C-COR.net FlexNet E629 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/c-cor-net/flexnet-e629/flexnet-e629_equipment-manual_478218025.webp)
Rev F
Physical Identification
2-9
2
19
Linear Power Supply
Converts AC power to regulated DC voltage for operation of the line
extender. (Only the transformer is visible.)
20
RAW DC T.P.
A testpoint to measure the unregulated DC voltage from the transformer
and rectifier. This should be between 28 and 35V
DC
.
21
RAW DC Voltage
Selector Switch
Adjusts the Power Supply transformer to the input AC voltage in order to
provide RAW DC between 28 and 35 V
DC
.
22
REVERSE B+ T.P.
Testpoint to measure the return power supply regulated DC voltage. This
should be 22.8 to 25.2V
DC
. Not available in units with an HEPSE90
power supply.
23
CABLE SELECT
TLC
only. Switch to match the temperature compensation circuit to the
cable preceding the line extender. Use
6 dB
for up to 10dB of preceding
cable loss; use
15 dB
for over 10dB of preceding cable loss.
24
TLC/MAN
Switch to enable or disable
TLC
.
MAN
provides a constant gain;
TLC
causes the line extender to monitor temperature to maintain preselected
output levels.
TLC
setting requires appropriate setting of the
CABLE
SELECT
switch.
25
RFI Filter
Blocks transmission of any RF signals into the 117V
AC
line. Used in
117V
AC
powered models only.
26
Detachable AC Power
Cord
Connection from 117V power supply to 110V wall socket.
27
REV OUTPUT TP
Directional testpoint for measuring return RF output signals.
28
AC TP
Testpoint for measuring AC power input to the power supply.
29
Integrated Power Supply
High efficiency power supply integrated into the RF module (see
on page 6-3) for replacement instructions).
1. Although labeled on the faceplate, the 862MHz/117V E7 Line Extender does
not
have a main fuse located on
the PCB. It is mounted on the RFI filter.
2. Although labeled on the faceplate, the 862MHz/117V E7 Line Extender does
not
have a through power fuse.
Table 2.1 Testpoints, Plug-in Locations, Connections, and Parts (cont’d)
Item
Number
Label
Function
Содержание FlexNet E629
Страница 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM ...
Страница 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1 ...
Страница 23: ...Rev F Physical Identification 2 7 2 Figure 2 6 E629 Line Extender 19 4 5 3 21 17 20 14 13 13 16 ...
Страница 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2 ...
Страница 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4 ...
Страница 82: ...A 6 FlexNet 700 Series Line Extender Rev F A ...
Страница 88: ...B 6 FlexNet 700 Series Line Extender Rev F B ...
Страница 102: ...C 14 FlexNet 700 Series Line Extender Rev F C ...
Страница 104: ...D 2 FlexNet 700 Series Line Extender Rev F D ...
Страница 110: ...Index 4 Rev F ...
Страница 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM ...