“There is no substitute for reading and understanding the operating manual however... You can use the instructions on this page for a 
trouble -free start-up”.

h

oW

 T

o

 s

TarT

-u

p

 T

he

 XGc

1)   Locate a suitable source for power. A 3-wire, grounded, 15-amp dedicated circuit is recommended.

2)   Secure the enclosure to a wall using the enclosed mounting “feet”. The XGC requires a vertical orientation for proper internal  

 

 

ventilation. If proper ventilation is not provided, the thermostat may not be able to properly control the temperature & humidity of the  

 

growing area.

3)   Plug the XGC into the power source. Do not connect your lights until you have set the “ON and “OFF” times on the 24-hour timeclock. 

4)   You may want to change the CO

2

 set point on the “Fuzzy Logic”

 controller. Normally 1250 to 1500 PPM is recommended for most    

 

applications. Once you set the PPM level, the built-in CO

2

 sensor and “Fuzzy Logic”

 module work together to actually dial-in the    

 

perfect parameters for YOUR area automatically. Refer to Changing the setpoint (SV).

5)   Now set the thermostat and de-humistat to the approximate settings you would like to use. A small, inexpensive combination  

 

 

thermometer and hygrometer works just fine to “dial in” the exact settings. Just compare the reading on the thermometer to what   

 

the XGC is set at and adjust as required. 

6)   You can now select the Hydro mode you would like to use. Choose between operating the Hydro outlet during the “Daytime” only    
 

or, 24-hours a day. Move the Hydro mode switch to the appropriate position. Moving the switch to the center “OFF” position  

 

 

momentarily will reset the timer.

7)   There are 2 timers on the XGC, which are used to control your hydroponics pumps. To fully understand the timers that control the    
 

XGC, refer to the Timers section of this manual.  Set the Hydro “ON” and “OFF” timers to your desired settings before continuing.    

 

(Refer to Timers)

8)   The 24-hour timeclock can now be set. Push in the trip levers on the front face of the timer dial for the time you want your lights to  
 

be “ON”. Rotate the dial to the current time to set the timer.

9)   Now you can plug the equipment you will be using into the appropriate receptacles. Remember that the XGC can handle a combined  
 

load up to 15-amps. A single 1000-watt HID ballast needs over 9-amps alone. Select and size your pumps and fans appropriately or  

 

use our UPM-1 or MLCs to increase power capacity. 

*Note: We highly suggest NOT plugging in your HID ballast just yet.

10) When the “day” cycle begins, the “Lights” indicator will light up to confirm power is going to the (2) light receptacles. If you have    
 

selected the “Daytime” setting on the Hydro mode, the “Hydro Pumps” indicator will also light up to indicate your pump    

 

 

is powered for the amount of time you selected

11) You can manually override the timeclock to switch from “night” to “day” or back to Night by rotating the outer dial of the timeclock  
 

slowly clockwise. At night, the Lights and CO

2

 are disabled while the thermostat and humistat continue to control the temperature   

 

and humidity. 

* NOTE: The Hydro outlet will also be disabled if the “Daytime” mode is selected on the Hydro mode switch.

12)  When all settings have been confirmed, the HID lights or UPMs can be plugged into the “Lights” receptacles. If more than 1000    
 

watts are to be controlled, use our Universal Power Modules or the MLCs.

* IMPORTANT: Do not plug in more than 1000 watts worth of lighting into the XGC receptacles. 

13)  Monitor the equipment connected to the XGC to ensure proper operation. Small adjustments are likely to be made until you find the  
 

right combination of controls. Once you are happy with the settings sit back and enjoy the show! 

For more details concerning any of the XGC functions, refer to the appropriate section of this manual.

Содержание XGC-1e

Страница 1: ...e maximum rating of the XGC 1e IMPORTANT Replace blown fuses with fuses of the same rating ONLY Note A surge suppressor power strip is always recommended when operating electrical equipment such as th...

Страница 2: ...the best all in one controller available Humidity Controller Temperature Controller 2 Light Outlets 2 Hydro pump Outlets Hydro OFF timer Hydro mode selector switch Fuzzy Logic CO2 controller Fuse pro...

Страница 3: ...ion of this manual Set the Hydro ON and OFF timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in the trip levers on the front face of the ti...

Страница 4: ...levels The de humistat can control humidity levels from 20 80 The de humistat is coordinated with the CO2 control system and the exhaust receptacles to maintain a constant humidity When the humidity r...

Страница 5: ...during the daytime only Simply moving the Hydro Mode selector switch to either the 24 Hour or the Daytime position enables the desired mode When used in the Daytime mode the Hydro outlet will only cyc...

Страница 6: ...ssible However if you suspect the higher temperatures are adversely affecting the plants a shorter CO2 cycle may produce better results Remember that a shorter CO2 cycle duration translates to increas...

Страница 7: ...is complete 14 Reconnect the Exhaust fans CO2 Disable cable and return the area to normal operation while monitoring the level of CO2 Do not continue to stand next to the XGC 1e while monitoring Just...

Страница 8: ...XGC 1e is capable of remaining in calibration for a minimum of three years Extreme shock during shipping and other factors may affect the calibration To check the calibration follow the procedure bel...

Страница 9: ...the HPR 1 The HPR 1 is rated at 30 amps 120 240 volt Master Lighting Controller Mlcs The MLC 4X and MLC 4XT Master Lighting Controllers are the best devices for controlling up to 4 HID lights from one...

Страница 10: ...circuits If the fuse blows repeatedly verify the devices connected to the unit are working properly and that they are not too large for the XGC 1e to safely control You may need to consider using exp...

Страница 11: ...00 PPM CO2 CO2 Warm up time Minimum 10 minutes full accuracy CO2 Maximum drift per year 15 PPM CO2 Accuracy 77 F 5 of reading CO2 Repeatability 1 of Fixed Scale CO2 Calibration interval Three years CO...

Отзывы: