roUbleShooting

If you are having problems with this unit, refer to these troubleshooting hints. Also, refer to the connection diagram to ensure your devices 
are connected properly. 

m

akinG

 c

onnecTions

All of the main functions controlled by the XGC are accessed using (8) standard 120 VAC, 15-amp receptacles mounted on the sides of 
the enclosure. This allows you to simply “plug in” any standard device without hardwiring or hassles. Printed labels on the front face of 
the enclosure identify the receptacles.

 We highly recommend using only 3-wire devices with a ground. Suitably double-insulated devices are acceptable. Keep in mind that the 
combined amperage draw on all of the devices connected to the XGC-1e must be less than 15-amps @ 120 VAC. 

Problem

•  I have no lights and no function at all.

•  The fuse continues to blow.

•  The fans are running so often, the CO

2

  

 

is hardly ever ON.

•  My CO

2

 consumption seems to be  

 

quite high. 

•  The Hydro pumps are not cycling  

 

properly.

•  The CO

2

 outlet is pulsing ON and OFF  

 

too often.

•  After my compressed bottle or LP tank  

 

was replaced, the level fluctuates.

•  My CO

2

 outlet never comes on.

Suggested Action

Check the fuse and main power. Replace the fuse if required with the correct rated fuse.   
Check the equipment connected to the XGC for problems and/or short circuits.

If the fuse blows repeatedly, verify the devices connected to the unit are working properly  
and that they are not too large for the XGC-1e to safely control.
You may need to consider using expansion modules, (UPM / HPR / MLC) to decrease the   
amperage (load) on the XGC fuse.

You may have too much heat building up in your area or too small of an exhaust fan.  

 

Reduce the heat sources or increase your fan size. 

You may also consider using a “closed-loop” air conditioner to keep the temperature and  
humidity below the set points so that CO

2

 is allowed to run for longer amounts of time.

Make sure your area is sealed. You may want to install a motorized damper to seal your    
exhaust fans when they are “OFF”. 

The Hydro pump outlets can be operated 24-hours a day or only when the “Lights” are “ON”. 
The “Hydro” selector switch also has a center “OFF” position, which can be used to “reset” the 
timing function. Make sure the switch is not turned “OFF”.

If you are running a CO

2

 generator, you may want to change to ON / OFF control. 

If running compressed CO

2

  you may want to try running an Auto tune.

If your CO

2

 tank runs out for a period of time, the controller may take anywhere from a few hours 

to a couple of days to re-stabilize, this is normal. When the tank ran out, the PPM-2a tried to 
compensate by changing its internal settings.

Make sure the CO

2

 disable function is not ON.

If the actual CO

2

 level is above the set point (SV) the outlet will not turn on. Allow the level to 

drop or raise the (SV).

Содержание XGC-1e

Страница 1: ...e maximum rating of the XGC 1e IMPORTANT Replace blown fuses with fuses of the same rating ONLY Note A surge suppressor power strip is always recommended when operating electrical equipment such as th...

Страница 2: ...the best all in one controller available Humidity Controller Temperature Controller 2 Light Outlets 2 Hydro pump Outlets Hydro OFF timer Hydro mode selector switch Fuzzy Logic CO2 controller Fuse pro...

Страница 3: ...ion of this manual Set the Hydro ON and OFF timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in the trip levers on the front face of the ti...

Страница 4: ...levels The de humistat can control humidity levels from 20 80 The de humistat is coordinated with the CO2 control system and the exhaust receptacles to maintain a constant humidity When the humidity r...

Страница 5: ...during the daytime only Simply moving the Hydro Mode selector switch to either the 24 Hour or the Daytime position enables the desired mode When used in the Daytime mode the Hydro outlet will only cyc...

Страница 6: ...ssible However if you suspect the higher temperatures are adversely affecting the plants a shorter CO2 cycle may produce better results Remember that a shorter CO2 cycle duration translates to increas...

Страница 7: ...is complete 14 Reconnect the Exhaust fans CO2 Disable cable and return the area to normal operation while monitoring the level of CO2 Do not continue to stand next to the XGC 1e while monitoring Just...

Страница 8: ...XGC 1e is capable of remaining in calibration for a minimum of three years Extreme shock during shipping and other factors may affect the calibration To check the calibration follow the procedure bel...

Страница 9: ...the HPR 1 The HPR 1 is rated at 30 amps 120 240 volt Master Lighting Controller Mlcs The MLC 4X and MLC 4XT Master Lighting Controllers are the best devices for controlling up to 4 HID lights from one...

Страница 10: ...circuits If the fuse blows repeatedly verify the devices connected to the unit are working properly and that they are not too large for the XGC 1e to safely control You may need to consider using exp...

Страница 11: ...00 PPM CO2 CO2 Warm up time Minimum 10 minutes full accuracy CO2 Maximum drift per year 15 PPM CO2 Accuracy 77 F 5 of reading CO2 Repeatability 1 of Fixed Scale CO2 Calibration interval Three years CO...