background image

 EN

  | 7

Nozzle

The nozzle assembly is located at the end of the sprayer. It is composed of a 
spring-loaded contact, external O-ring, nozzle cover, liquid tip and electrode. 
These are the only user-serviceable components. To access the nozzle 
components, unscrew the nozzle cover counterclockwise by hand. It is very 
important to follow all maintenance and cleaning procedures to ensure that the 
sprayer will function optimally. After servicing the nozzle, it is extremely important 
to return the nozzle to its seat position and avoid over-tightening.

NOTE: 

As the sprayer becomes dirty from typical use, a 70% isopropyl alcohol 

cleaner that is manually applied is recommended on the outside surfaces. This 
discourages dripping from the nozzle

.

1

Air Compressor

Atomizes and propels the liquid. 

Includes built-in auto-resetting 

thermal safeguard against 

compressor overheating.

2

Non-Marking Wheels

Large wheels, for easy transport and 

maneuverability, will not leave scuff 

marks. Do not require inflation.

3

Sprayer Connect Line

Connect line consists of three 

components: electrical line, liquid line 

and air line. The connect line connects 

the sprayer to the base unit.

4

Sprayer Holster

Holds the sprayer.

5

Handle Adjust 

Buttons

Adjusts handle height. 

(Squeeze to adjust.)

6

Removable Drip Cup

Collects any dripping from the 

sprayer.

7

Adjustable Handle

Handle position is raised, lowered  

and rotated by the two button snaps.

8

Peristaltic Pump

Provides liquid up to sprayer.

9

Circuit Breaker

User resettable circuit breaker and 

will only trip if a short occurs in the 

base unit.

10

Main Power 

Switch

Powers system to a ready state. 

11

1-Gallon Chemical 

Containers

Chemical containers  

(not included with equipment).

12

Extension Cord 

Holder

Located at the rear of the unit for 

extension cord storage.

13

Cord Management 

Hook

Stores or hangs the extension cord.

14

Frame

ABS and glass-filled nylon frame 

and hardware design for long-term 

durability. 

15

Pump Purge 

Switch 

Purges product from liquid line. 

(Press to purge.)

16

Sprayer Electrical 

Disconnect

Electrical connection for sprayer. 

17

Reservoir

A reservoir to ensure a consistent 

liquid flow.

ByoPlanet

®

 

ES

-150 Electrostatic Sprayer

1

5

2

4

3

1

Trigger Button

1-click functionality /

operates the sprayer/device.

2

Instrument Panel

Indicates the power, sprayer 

and electrostatics are on.

3

Nozzle Cover

Located on the front of the sprayer.

4

Sprayer Grip

Handle positioned for ambidextrous 

use.

5

Sprayer Connect

Connect line consists of three 

components: electrical line, liquid line 

and air line.

SYSTEM COMPONENTS

The patented ByoPlanet

®

 Electrostatic Spray Systems were engineered with 

the end-user in mind. It is durable, highly  mobile and incredibly effective for 
electrostatic delivery.

ByoPlanet

®

 

MS-7

15

 

& MS-740 

Compact Series Base Unit

Содержание CS-2015 Series

Страница 1: ...utdoor Commercial Use Operator s Manual 2 13 For service and support contact Service Tech Team www servicetechteam com EN ByoPlanet Compact Cart Electrostatic Spray Systems Electrostatic Sprayer MS 715 CS 2015 Series Electrostatic Sprayer MS 740 CS 2040 Series ...

Страница 2: ...xtension Cord Shock Electrical Hazard General Safety Chemicals ByoPlanet MS 715 MS 740 Compact Series Base Unit ByoPlanet ES 150 Electrostatic Sprayer Nozzle ByoPlanet CS 2015 CS 2040 Cart Series OPERATING INSTRUCTIONS Preparing the Spray Area Unit Preparation Setup Sprayer Operation During Use Changing ByoPlanet Approved Products After Use and Storage MAINTENANCE Sprayer Body Peristaltic Pump Noz...

Страница 3: ...ined personnel WARNINGS PRESSURIZED EQUIPMENT HAZARD Fluid from equipment that leaks or ruptures from a component can splash in the eyes or on skin causing serious injury In order to help prevent a leak or rupture Check hoses tubes and couplings daily Replace worn or damaged parts immediately WARNINGS PLASTIC PARTS CLEANING SOLVENT HAZARD Many solvents can degrade plastic parts and cause them to f...

Страница 4: ...Systems can only be used with products that have been approved by ByoPlanet Never spray any liquid product that is not a ByoPlanet approved product The ByoPlanet Electrostatic Spray Systems warranty is voided if the ByoPlanet Electrostatic Spray Systems are used with products that are not approved by ByoPlanet Be aware that many chemical liquids can be harmful if they are not used properly Read an...

Страница 5: ... must be grounded In the event of malfunction or breakdown grounding provides a path of least resistance for an electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ord...

Страница 6: ...m cord 12 13 A sprayer should never be left unattended when plugged in A resettable breaker is provided on the rear of the unit It will trip if the unit experiences an electrical short 14 Always turn off sprayer after each application and before unplugging 15 16 Always unplug unit from outlet when not in use or when leaving it unattended Never unplug by pulling the cord or with wet hands Always un...

Страница 7: ...ects any dripping from the sprayer 7 Adjustable Handle Handle position is raised lowered and rotated by the two button snaps 8 Peristaltic Pump Provides liquid up to sprayer 9 Circuit Breaker User resettable circuit breaker and will only trip if a short occurs in the base unit 10 Main Power Switch Powers system to a ready state 11 1 Gallon Chemical Containers Chemical containers not included with ...

Страница 8: ...dle grips 3 Reel Mounting Plate Reel is mounted to this plate 4 Sprayer Holster Holds the sprayer 5 Removable Drip Cup Collects any dripping from the sprayer 6 Extension Cord Hook Holds the extension cord when not in use ByoPlanet CS 2015 CS 2040 Cart Series Base Unit 1 Base Unit Contains pump controls etc 2 Cart Provides unit mobility 3 Reel Retracts and stores hose CS 2015 Base Unit Comprised of...

Страница 9: ...System base unit 8 Store in a safe dry place 1 Clean gross filth by using standard manual cleaning protocols 2 Close the room to the general public for cleaning Place signs or warning indicators on doors that indicate no one should enter the room 3 Power off any sensitive electrical devices but do not unplug them Unit Preparation Setup 1 Choose the appropriate Byoplanet approved product for cleani...

Страница 10: ...h a pair of pliers Otherwise service the spring loaded contact by applying a generous amount of dielectric grease available at any local automotive hardware store 4 Be sure to also thoroughly clean all interior surfaces of the nozzle cover including the main orifice Never use a wire brush file or sandpaper to clean any surface or orifice Important The nozzle cover should be hand tightened Never us...

Страница 11: ...V Model Volts 240V Running AMPS 3 0 Startup AMPS 7 0 Frequency 50 Hz Standard Hose Length 7 ft 2 13 m Dimensions 29 25 in 0 74m H x 10 00 in 0 25m W x 16 00 in 0 40m L Air Line Pressure 35 psi 2 4 Bar Weight Empty 43 lbs 20 kg Weight Full 59 lbs 27 kg Shipping Weight 52 lbs 24 kg Flow Rate 4 3 oz min 130ml min Volts 240V Running AMPS 3 0 Startup AMPS 7 0 Frequency 50 Hz Standard Hose Length 30 ft ...

Страница 12: ...Unit stalls at initial trigger This may be a sign of a cold start Warm unit up by pressing the trigger and letting unit run for up to two minutes Trigger off then on Unit should run normally TROUBLESHOOTING NOTE Do NOT use a chemical in the unit that is not a ByoPlanet approved product If you encounter the issues listed below use the suggested troubleshooting methods If you encounter an issue that...

Страница 13: ... by ByoPlanet duty taxes charges for normal service or adjustments loss of income expenses due to loss damage detention or delay in the delivery of equipment or parts resulting from acts beyond the control of ByoPlanet THIS WARRANTY SHALL NOT APPLY TO 1 Defects failures damages or performance limitations caused in whole or in part by a b Power failures surges accidents actions of third parties wea...

Страница 14: ... Road Sunrise FL 33326 1 855 211 1518 www byoplanet com ByoPlanet International LLC 1002 Winterville Road Athens GA 30605 1 855 211 1518 www byoplanet com Electrostatic Sprayer MS 715 CS 2015 Series Electrostatic Sprayer MS 740 CS 2040 Series ...