background image

MAINTENANCE

OPERATOR MANUAL

62

EPS14P

63

OM-EPS14P2019001-EN

Schematic of Electrical System

Display

ALARM

Fault name

Recommended inspection

02A00

BATTERY LOW

Battery level low

If the parameter “BATTERY CHECK” is not set to zero, no LED representing battery state-

of-charge will come on when battery state-of-charge is less than 15%. The warning will be 

displayed and the lift function of the forklift will be disabled. In this case, it is imperative 

to charge the battery. If the battery is operational, check whether the controller parameter 

“ADJUST BATTERY” agrees with the battery voltage.
Battery charging

EPS RELE OPEN

EPS relay open

Check whether the EPS controller has fault

DATA ACQUISITION

Data collection

Activation of this fault indicates data acquisition is under way. Wait data acquisition is 

completed.
Do not operate during data collection and restart after completing

CHECK UP NEEDED

Maintenance interval Maintenance interval is expired. Maintenance is required.

Change CHECK UP DONE to ON, turn off and restart

02A01

WRONG CONFIG

Wrong configuration Clear EEPROM

02A08

 

WATCHDOG      

Watchdog fault

Turn the key switch to “START”, to see whether the watchdog circuit is activated 

before the software is run. In the standby or operation state, the watchdog signal 

is invalid (alarm state).

Fault analysis: The watchdog hardware circuit or microcontroller output section 

is damaged. Neither of the two cases is associated with external components. 

Replace the controller.

       

FLASH CHECKSUM 

Flash memory fault

With the key switch turned to “ON”, the value stored in the flash memory by 

the program should be a positive value. This fault will be reported in the case of 

a negative value. Fault analysis: The flash memory of the microcontroller could 

become faulty. The flash memory, or the program stored could be damaged. 

Attempt to configure the program of the logic card again. If the fault is still there, 

it exists in the microcontroller. Replace the controller.

       

WATCHDOG#2     

Watchdog fault 2

Possible cause: During startup of the forklift, the watchdog circuit has been 

activated before the software is initiated. In the standby or operation state, the 

watchdog signal is invalid (alarm state). Fault analysis: The watchdog hardware 

circuit or microcontroller output section is damaged. Neither of the two cases is 

associated with external components. Replace the controller.

02A10

        

WRONG  RAM   

F a u l t   w i t h   t h e 

dynamic memory

The fault is detected when the main memory is tested. Registered address is 

“DIRTY”. This fault can limit the operability of the forklift.。

Fault analysis: Turn the key switch to “OFF”, then to “ON”. If the fault still 

exists, replace the controller。

02A11

      

 STALL ROTOR    

Motor stalling

1.Motor stops running.2.Motor encoder fault3.Damaged harness or incorrect 

wiring connection.4.Problem with power supply to the encoder.

02A13

EEPROM KO

EEPROM error

1. Restart the key switch, if the fault still exists, please replace the controller; 2. 

Restart the key switch, if the fault disappears, please reset the parameter.
Perform CLEAR EEPROM operation. If the fault disappears, change the parameters 

one by one to the set value. If the fault does not disappear, replace the controller.。

PARAM RESTORE

Parameter restore

If the CLEAR EEPROM operation has been performed, the fault prompt parameter 

is restored to the default; if there is no CLEAR EEPROM, there is a fault inside the 

controller.

02A16

AUXOUTPUT KO

E l e c t r o m a g n e t i c 

brake coil fault

Check the electromagnetic brake coil for abnormality. If not, replace the controller

02A17

 LOGIC FAILURE #3  

Logic fault #3

Sudden disconnection during working of coil output line./ Fault with the current 

protection function of logic card The controller should be replaced.

02A18

 

LOGIC FAILURE #2

Logic fault #2

1. Check the motor power circuit for problems, including the fuse of controller; 

2. Check the parameter table; 3. If there is no problem with the above two items, 

replace the controller.

02A19

 LOGIC FAILURE #1

Logic fault #1

1. Test the battery voltage; 2. Check if the ADJUST BATTERY in the controller 

matches the actual battery voltage.

02A20

 HEIGHT SENS OPEN

02A21

  

CHARGE SAFETY  

Charge safety

This fault can be reported if the forklift is operated while the battery is being 

charged. This prevents anyone from operating the forklift while the battery is 

being charged.

02A22

 HEIGHT SENS LOCK
reset cutback 1

02A26

CURRENT SENS. KO

02A27

 PHASE KO      

Open circuit of U/V/

W phase

Check whether U/V/W phase is correctly connected.

Fault Code Table

Содержание EPS14P

Страница 1: ...EPS14P OPERATOR MANUAL OM EPS14P2019001 EN...

Страница 2: ...EPS14P OPERATOR MANUAL OM EPS14P2019001 EN...

Страница 3: ...ift nameplate 18 Battery Nameplate 19 Loading Capacity Chart 19 Other decals 20 OPERATING Startup and Control Key Switch 22 Emergency Disconnect Switch 22 Fork carriage and pedal 22 Tiller 23 Travel S...

Страница 4: ...eplacement 46 Driving Wheel Replacement 46 Gear Oil Level Checking 47 Gear Oil Replacement 48 Mast Maintenance Chains Adjustment 49 Chains Lubrication 51 Mast Cleaning 51 Mast Clearance Adjustment 52...

Страница 5: ...onments other than those mentioned in this manual contact with your local BYD dealer first for confirmation Any modification to the forklift is not allowed unless BYD s written consent is granted Cont...

Страница 6: ...ake sure that the operators understand all the safety messages on the forklifts For the proprietor make sure following safety instruction on your industrial vehicles are observed Please abide by relev...

Страница 7: ...he forklift when the abnormalities and damages are found on the forklift Do not use the forklift until the forklift is fully repaired Warning decals and signs The BYD forklifts have warning decals and...

Страница 8: ...l View 3 1 12 14 13 6 8 5 10 15 2 11 9 7 4 No Name No Name No Name 1 Fork Load Wheel 6 Battery Cover 11 Cover 2 Forklift nameplate 7 Tiller 12 Castor Wheel 3 Fork 8 Emergency Disconnect Switch 13 Driv...

Страница 9: ...mm 2372 Turning radius LH RH Wa mm 1490 1970 Performance Data Travel speed with without load km h 6 6 Lift speed with without load mm s 180 240 Lower speed with without load mm s 300 240 Climbing abil...

Страница 10: ...e load it should not exceed the rated loading capacity of the forklift Check and confirm the load of the forklift Battery Nameplate Opera ng Condi ons Iron Phosphate Battery Ambient Temperature Rela v...

Страница 11: ...the weight of the cargo S14PS Q kg H mm C 600 mm 2800 3300 3800 4300 4800 550 750 1000 1200 1400 Caution 1 Forklift specification varies depending on customer requirements Refer to the load capacity...

Страница 12: ...starting the forklift pull up the emergency disconnect switch on the right side Emergency Disconnect Switch Press down the emergency disconnect switch to shut off the power Rotate and pull up it to r...

Страница 13: ...s of A1 and A3 to brake Release the accelerator button B to brake when the vehicle speed is 0 apply the brake immediately A1 A2 A3 B Low Speed Control Press the low speed control below the tiller and...

Страница 14: ...vehicle being normally started 5 Hours and Fault Code The time worked appears after the vehicle being normally started The fault code appears when the vehicle breaks down 6 Battery state The battery l...

Страница 15: ...he packaging of the goods and the handling personnel should bear the responsibility of safe loading Travelling 1 When travelling with load make sure that the load is well centered on the forks 2 After...

Страница 16: ...the charger to charge the forklift GB port REMA port Optional Note 1 If the charge port cover is opened it is impossible to use the stacker To use the stacker close the charge port cover 2 The environ...

Страница 17: ...vehicle on turtle speed mode Caution 1 Have a supervisor or a second person on site as a lookout 2 Make sure that the ground is strong enough to avoid the transport vehicle sinking into the floor 3 S...

Страница 18: ...om the battery power and press down the emergency disconnect switch Battery status of charge should be around 50 to avoid over discharge or full charge for long term storage 8 Use and operate the fork...

Страница 19: ...if any parts loose or fall off Note If oil leakage occurs confirm the location of the oil leakage and contact the BYD after sales service 2 Wheel 1 Check on a daily basis if the wheel fasteners are s...

Страница 20: ...every 6 weeks otherwise conduct the following inspection and checks every 250 hours Perform the maintenance service accordingly Category Item 6 weeks 3 6 12 Months 250 500 1000 2000 Hours Chassis Syst...

Страница 21: ...ck if fuse and relay work properly and replace them if necessary Warning Disconnect the battery before checking the electric system 5 Others Check torque on critical fasteners CONSUMABLE ITEMS Type an...

Страница 22: ...block the vehicle Emergency Lowering If the fork can t be lowered by a fault of the vehicle loosen the pressure relief switch to lower the fork After lowering the fork tighten the pressure relief swi...

Страница 23: ...ehicle shakes turn the retainer downward 1 2 19 22 21 11 19 22 21 11 CODE PART NAME QTY CODE PART NAME QTY 11 RETAINER 1 21 BOLT M12 45 1 19 WASHER M12 1 22 SPRING WASHER 1 Load Wheel Replacement 1 Us...

Страница 24: ...he hardwood block under it Loosen the nuts to replace the wheel CODE PART NAME QTY 11 NUT 5 90 N m 12 SPRING WASHER 5 Caution After replacement the truck balance should be adjusted Gear Oil Level Chec...

Страница 25: ...keep people away and do not pour it into the sewer or onto the ground 4 The oil level should be just at the lower edge of the oil filler hole MAST MAINTENANCE Chains Adjustment The standard mast has...

Страница 26: ...ake the forks remain level and the chains remain the same tightness and them tighten nuts CODE PART NAME QTY CODE PART NAME QTY 11 NUT UPPER 1 110 N m 13 NUT LOWER 1 110 N m 12 NUT MIDDLE 1 110 N m Ch...

Страница 27: ...Lift the mast to expose the position of the adjusting screw 2 Bend the secure pin to expose the adjusting screw 3 Use the screw to adjust the clearance 4 After adjustment bend the secure pin to secure...

Страница 28: ...the waste oil keep children away and do not pour it into the sewer or onto the ground 4 Using unauthorized hydraulic oil might cause damage to hydraulic system Use only authorized hydraulic oil If you...

Страница 29: ...other types of hydraulic oils contact with the BYD forklift after sales service people ELECTRIC SYSTEM MAINTENANCE Warning Disconnect the battery before checking the electric system Electrical Wiring...

Страница 30: ...n Check whether low voltage fuse and relay work properly Replace them if necessary TORQUE INSPECTION ON CRITICAL FASTENERS Torque Inspection on Wheel Fasteners 1 2 11 13 12 CODE PART NAME QTY CODE PAR...

Страница 31: ...MAINTENANCE OPERATOR MANUAL 60 EPS14P 61 OM EPS14P2019001 EN Mast Fasteners Torque Checking 11 11 11 11 12 12 CODE PART NAME QTY 11 BOLT 4 100 N m 12 SCREW 2 30 N m SCHEMATICS Hydraulic Schematic...

Страница 32: ...atchdog signal is invalid alarm state Fault analysis The watchdog hardware circuit or microcontroller output section is damaged Neither of the two cases is associated with external components Replace...

Страница 33: ...ll disengage and the warning will occur The warning will not occur next time the forklift is operated Display ALARM Fault name Recommended inspection 02A52 PUMP I 0 EVER Oil pump I 0 fault Check wheth...

Страница 34: ...s necessary to replace the controller COIL SHOR MC EB Main contactor or elec tromagnetic brake is heavily loaded 1 Check whether the output and load of the controller are excessive 2 Replace the contr...

Страница 35: ...power supply cable is firmly connected to the controller 3 Check if the controller U phase wire is connected properly 4 Replace the controller 06A04 POWER FAILURE 3 Power fault 3 1 Check if the contro...

Страница 36: ...cation is consistent 3 Check if the CAN communication is open 4 Check if the CAN communication loop resistance is 60 06A38 POSITION ERROR Position error 1 Check if the steering motor encoder A and B p...

Страница 37: ...230 Terminal Intermodal de Cargas TIC CEP 13069 119 CAMPINAS SP Tel 55193514 2551 E mail FORKLIFTSERVICE BYD COM Importer BYD Japan company Limited Address The fth Yasuda Bldg 5F 2 20 3 Tsuya cho Kan...

Страница 38: ......