background image

 

BXB ELECTRONICS CO., LTD.   

 

5

                                  Safety Instructions                                 

1.  Please read and observe these instructions before installing and using the apparatus. 

2. 

Use only accessories specified by the manufacturer. The manufacturer is not liable for damage 

caused by the use of non-specified accessories. 

3.  Install the apparatus and its accessories carefully. Strike and fierce shaking may damage the 

apparatus. 

4.  Make sure the power cord is fixed properly. 

5.  Do not overload wall outlets and extension cords as this can result in a risk of fire or short circuit. 

6.  To reduce the risk of damage from lightning strikes, it is important that all electric cables should 

be bonded to the same grounding point. 

7.  Do not block any ventilation openings to prevent overheating and malfunction. 

8.  Do not expose the apparatus to rain or moisture. 

Humidity may lead inside components to damage. Appropriate shelter is necessary when placing 

it outside (Best working environment: Temperature 0°C ~ 40°C <32°F ~ 104°F>, humidity below 

90%). 

9.  Please do not switch on and off the apparatus rapidly. 

Rapid switch on and off the apparatus should be avoided all the time to prevent inside sensitive 

electronic circuits from being damaged by surges. 

10. Do not clean the apparatus and its accessories with chemical solvents. Use only a clean, 

dry/dampish cloth. 

11. Refer to maintenance technician when the apparatus has been damaged in any way, such as: 

A• power-supply cord or plug is damaged 

B• liquid has been spilled in 

C• has been exposed to rain or moisture 

D• has been dropped 

E• objects have fallen into the apparatus 

F• does not operate normally 

12. Note: When the printed circuit board is going through electric static treatment, correct ESD 

safety precaution and grounding should be assured.   

13. 

Note: Before connecting the apparatus to main AC, please select the supply voltage in 

accordance with the wall voltage in your country to prevent damage. Refer to Installation and 

Setting (Page 8) for selecting.

 

14. 

Warning: Do not disassemble or remodel the product, as these actions may lead to electrical 

shock or damage. The guarantee on the product will become null if the product is ever 

disassembled.

Содержание WMP-1206

Страница 1: ... S Sp pe ea ak ke er r C Ci ir rc cu ui it t Z Zo on ne e S Se el le ec ct to or r U Us se er r M Ma an nu ua al l V V Ve e er r rs s si iio o on n n 1 1 1 1 1 1 D D Da a at tte e e O O Oc c ct tto o ob b be e er r r 1 1 18 8 8 2 2 20 0 01 1 11 1 1 ...

Страница 2: ...BXB ELECTRONICS CO LTD 2 Contents 2 Overview 3 System Features 4 Safety Instructions 5 Operation and Features 6 Front Panel Description 6 Rear Panel Description 7 Connection 8 Contents ...

Страница 3: ...ea broadcast button 1 programmable group button and 1 all call button to make your PA system even more powerful Built in RS 485 RS 232 and USB ports facilitate integrating with other control systems High reliability is our utmost purpose when developing BXB system Each main control unit and its fittings have all gone through careful assembly and strict test in our ISO 9001 approved factory The exc...

Страница 4: ... flip flops for remote activate timer clock 10 Output control flip flops for remote activate amplifier 11 WMP 1206 can be used individually or used with digital analog connect With RS 485 port it can expand another WMP 1206 expand apparatuses are unlimited when using analog contacts Specification Power Supply DC15V 1A MAX Output 12 areas 300W each zone maximum 3600W in total 12 single zone switche...

Страница 5: ...F humidity below 90 9 Please do not switch on and off the apparatus rapidly Rapid switch on and off the apparatus should be avoided all the time to prevent inside sensitive electronic circuits from being damaged by surges 10 Do not clean the apparatus and its accessories with chemical solvents Use only a clean dry dampish cloth 11 Refer to maintenance technician when the apparatus has been damaged...

Страница 6: ...d you can broadcast to preset groups Preset groups Press the single zones that you want to added in the group button LED is on and then press the group button for three seconds flashing LED means setting is saved Repeat instructions above to change setting Reprogram the memory is not essential 4 Group broadcast LED indicator 5 All zone broadcast LED indicator Operation and Features ...

Страница 7: ... control systems 4 USB 2 0 USB port connects to PC for BXB graphical control software 5 RS 232 communication port for other control systems 6 ID DIP switch identity code for expanders 7 External dry contact all zone broadcast activates when contacted 8 Dry contact contacted when WMP 1206 is activated to activate amplifier 9 WMP 1206 working voltage DC12V DC15V MAX ...

Страница 8: ... Contact Input Ceiling mounted or Wall Speaker High Voltage Signal High Voltage Signal Zone 2 Zone 12 Max 300V for each zone LEVEL POWER PL AC 0FF ON AUTO FUSE AUTO FUSE DC 400W Amplifier 1 2 3 4 5 6 8 7 9 10 11 12 ALL Call 12 Zone Speaker Circuit Selector 1 2 3 4 5 6 8 7 9 10 11 12 ALL Call 12 Zone Speaker Circuit Selector Paralleled Dry Contacts LEVEL POWER PL AC 0FF ON AUTO FUSE AUTO FUSE DC 40...