DECIDING WHEN TO REGENERATE THE SF METERED SOFTENER

Because the Softener works on a metering device, this allows it to decide the frequency of regeneration that best suits your
needs. Simply program the incoming mains hardness and the softener will do the rest! 

COMMISSIONING THE SF METERED SOFTENER

SET THE PROGRAMMER

Obtain your water hardness from your local water authority, or alternatively purchase a Test Kit from your supplying retailer. 
To set the programmer refer to instructions on facial panel.

Carefully remove the control valve cover by lifting gently under the front edge.

Depress and turn black pointer knob ‘H’ (Fig. 6) on the control, anticlockwise using broad headed screwdriver, to the backwash
position. Assist this movement by simultaneously turning the camshaft with your other hand.

Close the by-pass valve as Fig. 1. Open inlet valve partially by turning. The blue resin vessel should now be heard to fill with
water. Air in the resin vessel and valve will be evacuated out of the drain pipe.

When water starts running from the drain, open the inlet valve fully and allow to run for three minutes.

Turn pointer knob ‘H’ anticlockwise to a point just before the 

FAST RINSE REFILL

position.

Switch on power supply. Check that clock motor can be heard running.

Allow motor to run pointer knob anticlockwise to 

SOFTENED WATER

position. Allow approximately 10 minutes.

Fill brine storage tank with salt to a level not exceeding 75mm below the bottom of the salt lid opening. Granular or tablet salt is 
suitable. The salt will be dissolved and gradually used by the machine. A visual check should be carried out on a 3 to 6 weekly interval
(depending on usage). Top up as necessary. Always ensure a minimum salt level of 125mm exists above the base of the cabinet.

Fully open outlet valve as Fig. 1. You now have softened water.

Set the time of day (see Adjustment of Timer).

ADJUSTMENT OF TIMER (METERED VERSION)

Open the access door ‘D’ (see Fig. 6).

The hardness and capacity have been set at the factory. Unless you need to alter the hardness for your area (it is set to 17 GPG
(Grains Per Gallon) or 290 p.p.m.), no further adjustment should be made.

If for any reason you should wish to alter the time or hardness proceed as follows. 

The use of a pair of small needle nose pliers or tweezers will aid in moving the jumper.

With the “jumper” on the top 2 pins next to the word “

TIME

” (Fig. 7/2), set the time-of-day to the closest hour by depressing

the black 

TIME SET BUTTON ‘E’

.

If you need to adjust the hardness, pull the jumper off the top 2 pins and place it on the next set of pins next to the word

HARDNESS

(Fig. 7/1). Depress the black 

TIME SET BUTTON ‘E’

until the correct hardness is displayed. The hardness range is

from 1 to 99 grains per gallon.

To change the water hardness from parts per million or mg/l to grains per gallon as displayed use this formula:

Divide the p.p.m. by 17.1 to get the G.P.G.

Capacity is pre-set - do not alter. (Fig. 7/3)

Return the jumper to the top set of pins next to the word “TIME” and close the access door. The bottom 3 sets of pins are used
for factory testing and are not used in normal operation. The jumper must NOT be left on any pins other than the top pair next
to the word “TIME”. Failure to do this will cause the unit not to operate.

In the event that the hardness or capacity setting must be changed, simply follow steps 1 through 6. The new information will
be entered when the jumper is returned to the top 2 pins next to the word “TIME”.

Manual Regeneration. Push in black pointer knob ‘H’, Fig. 6, until click is heard. This will start a regeneration. It takes 
approximately 90 minutes to complete a full regeneration.

INSTALLATION 

(cont)

12.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

13.

1.

Note

Note

2.

3.

4.

5.

6.

TIME

HARDNESS

CAPACITY

A

B

SPARE

FIG. 7/1

FIG. 6

TIME

HARDNESS

CAPACITY

A

B

SPARE

FIG. 7/2

TIME

HARDNESS

CAPACITY

A

B

SPARE

FIG. 7/3

Access 
door ‘D’

24 Hour/Time
(display ‘F’)

Time set 
button ‘E’

Black
pointer
knob ‘H’

NOTE: The wording 
around pointer knob 
‘H’ may vary

Water flow (indicator ‘K’) flashes when 
water is passing through (no volume given)

Electrical connection point

Initiate a manual
regeneration by 
pressing the button
on the left of the
control panel.

Содержание SF 10 Litre Timed

Страница 1: ...in the loft the following instructions should be strictly adhered to The water softener should be installed within a container of not less than 113 65 Litres 25 gallons capacity to which there shall...

Страница 2: ...water to again enter the system CONNECTING INLET OUTLET HOSES MODEL SF 10 Litre Timed Fit the two 3 4 nylon nipples into inlet and outlet sockets Use a suitable thread sealer such as PTFE tape All MOD...

Страница 3: ...discharging into a stand pipe always leave an air gap between water level and hose outlet Secure the hose at stand pipe to prevent kinking and accidental removal or blow out of the hose Using the plas...

Страница 4: ...t to Sections 12 COMMISSIONING THE WATER SOFTENER ALL MODELS It will be necessary to ascertain the hardness of your water This information is available from your local water supply company Alternative...

Страница 5: ...een set at the factory Unless you need to alter the hardness for your area it is set to 17 GPG Grains Per Gallon or 290 p p m no further adjustment should be made If for any reason you should wish to...

Страница 6: ...why we offer a range of unique service programmes carried out by the manufacturers own national service team Telephone for details on 01376 334 200 SALT Salt is essential to make the water softener wo...

Страница 7: ...system please call us on our helpline USEFUL NOTES For manual regeneration see Adjustment of timer section 10 4 or 13 6 For minimum and maximum salt levels see section 9 paragraph 8 or section 12 para...

Страница 8: ...nge without prior notice E OE Please retain this manual Culligan International UK Limited Culligan House Coronation Road High Wycombe Buckinghamshire HP12 3SU United Kingdom Tel 01376 334 200 Fax 0137...

Отзывы: