10.
TECHNICAL SPECIFICATION
10.1
Technical specifications
BWT PERMAQ
®
Pro 1800
Tag number
Description
Type/data
P1a
High-pressure pump
2.2 kW, 4.45A
P1b
High-pressure pump
2.2 kW, 4.45A
P2 (option)
Transport pump
0.85 kW, 4.5A / 1.2 kW, 4.8A
FI 1
Flow meter
Ø32 PVC
PI 1
Manometer
0-40 Bar, ¼”
V1
Needle valve
Brass
V2
Needle valve
Brass
Y1
Solenoid valve NC
POM
PS 1
Pressure switch NO
¼” 0.5 Bar
PS 2 (option)
Pressure switch NC
¼” -0.2 - 8 Bar
QIS 1 (option)
Conductivity meter
½” Connection for sensor
10.2
Technical data
BWT PERMAQ
®
Pro 1800
1810
1820
Capacity
l/h*
500
1000
Number membranes
pcs
1
2
Maximum water recovery
%
75-80
Weight (full)
kg
60
70
Salt retention
%*
>99
Conductivity
µS/cm*
<20
Power connection
V
400
Power consumption
kW/m³
2,76
2,05
Electrical frequency
Hz
50
Pipe inlet
inch
¾"
Concentrate outlet
mm
14
Permeate outlet
mm
14
Width, Depth, Height (BxDxH)
mm
650x550x1600
Water temp. (Min./Max.)
C
5 / 35
Inlet water pressure (Min./Max.)
bar
3 / 7
High pressure pump
Tag number
P1a
P1b
* At drinking water quality 10
C, 3 bar, max. 500 mg/l total salt content.
Содержание PERMAQ PRO 1810
Страница 1: ...Installation and operating Instruction EN BWT PERMAQ PRO 1810 1820 Reverse Osmosis Plant ...
Страница 2: ...EN 2 ...
Страница 10: ...EN 10 9 2 2 The quality of the treated water is higher than 20 µS cm 9 2 3 Alarm Low feed water pressure ...
Страница 11: ...EN 11 9 2 4 Alarm Transport pump 9 2 5 Indication Level low ...
Страница 18: ...EN 18 13 1 P I Diagram ...
Страница 19: ...EN 19 13 2 Layout Drawings ...
Страница 20: ...EN 20 13 3 Wiring Diagram ...
Страница 21: ...EN 21 ...
Страница 22: ...EN 22 ...
Страница 26: ...EN 26 13 7 Spare Parts Drawing ...